DOWNLOAD JBL SUB 260 (serv.man3) Service Manual ↓ Size: 722.81 KB | Pages: 7 in PDF or view online for FREE

Model
SUB 260 (serv.man3)
Pages
7
Size
722.81 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sub-260-sm3.pdf
Date

JBL SUB 260 (serv.man3) EMC - CB Certificate ▷ View online

 
 
page 3 of 4 
Ref.No.: 520081 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
14 COMPONENTS 
 
14.1 
Resistors 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
  
 
a) Resistors separately approved ......................... : No 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N 
 
b) Resistors separately approved ......................... : No 
14.2 
Capacitors and RC units 
 
Capacitors separately approved 
  
14.2.1 
Y capacitors tested to IEC 60384-14, 2:nd Edition :   
  
14.2.2 
X capacitors tested to IEC 60384-14, 2:nd Edition :  Across mains switch 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ..................... :
 N 
14.2.5 
Capacitors with volume exceeding 1750 mm
3
 
where short-circuit current exceeds 0.2 A: 
compliance with IEC 60384-1, 4.38 category B or 
better ..................................................................... :
 N 
 
Capacitors with volume exceeding 1750 mm
3
mounted closer to a potential ignition source than 
Table 5 permits: compliance with IEC 60384-1, 
4.38 category B or better ....................................... :
 N 
 
Shielded by a barrier to FV 0 or metal  .................. :   
14.3 
Inductors and windings 
14.3.1 
Transformers and inductors marked with 
manufacturer’s name and type  ............................. :
Transtec TT0869803320 alt. 
TT0869803320-E 
 
Transformers and inductors separately approved  : No 
14.3.2 
Isolating transformer complies with 14.3.3, 
14.3.4.1 or 14.3.4.2 and 14.3.5.1 or 14.3.5.2 …….:
14.3.3, 14.3.4.2 and 14.3.5.2 
 
Separating transformer complies with 14.3.3, 
14.3.4.3 and 14.3.5.1 or 14.3.5.2 …….……………:
 N 
 
Flammability test of insulating material acc. to 
20.1.4 (except in thin sheet form) 
 P 
14.3.3.1 
Clearances and creepage distances according to 
clause 13 
 P 
14.3.3.2 
Transformers meet the constructional 
requirements 
 P 
 
 
page 4 of 4 
Ref.No.: 520081 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
14 
TABLE: list of critical components and materials 
Object/part No. 
Manufacturer/ 
trademark 
Type/model 
Technical data 
Standard 
Mark(s) of 
conformity 
Mains 
Transformer 
Transtec 
TT0869803320 
AC 230-240V 
IEC 60065 
— 
Thermal release 
Joint Force 
M33 
2A, 250V, 
130
°C 
IEC 60691 
TÜV 
*) Alt. Mains 
Transformer 
Transtec 
TT0869803320-E
AC 230-240V 
IEC 60065 
— 
*) Thermal link 
Joint Force 
L33 
2A, 250V, 
130
°C 
IEC 60691 
TÜV 
Mains Fuse 
Walter 
TSD 
T1.25AL   250V
IEC 60127 
 
Mains 
fuseholder 
Chin Shin 
(Walter) 
R3-11 
10A 250V 
IEC 60065 
— 
IEC 61058-1 
 
Mains switch 
Rong Feng Ind. 
Co., Ltd 
RF-1003 10(4) 
8/80A, 
250V Class II 
IEC60065:98 
Annex G 
NEMKO 
Cordset: 
plug 
I Sheng 
 
SP-021A 
 
2.5A   250V 
 
CEE 7 
 
cord 
 
H03VVH2-F 
2 x 0.75mm² 
IEC 60227 
 
UK Cord set: 
Plug with fuse 
Luen Tai 
Electric 
 
9518 
 
13A   250V 
 
BS 1363 
 
BSI 
cord Rhythm 
Wire 
Ind. Co., Ltd. 
 
H03VVH2-F 
 
2 x 0.75mm² 
 
IEC 60227 
 
KEMA 
Cord set Korea: 
plug 
Volex  
MP2217 
 
3A   250V 
 
KS C8305 
 
cord 
 
VCTFK 
2 x 0.75mm² 
KS C3304 
 
Transformer 
Bobbins  
EI Dupont de 
Nemours 
Nylon 66 
101,101F 
94V-2 Complies 
with 
FH 3-40mm/min 
IEC 60707:81 
— 
Mains fuse 
holder 
Walter 
R3-11 
Min. FV 1 
IEC 60707 
— 
Sec. connector 
P103 
JWT 
A3963Wv2-5P 
Min. FV 1 
IEC 60707 
— 
PCB Jian 
He 
(Cheng Ho) 
Various 
Min. FV 1 
IEC 60707 
— 
X capacitor  
across the 
mains switch 
Europtronic 
(Taiwan) Ind. 
Corp. 
MPX 0.10µF, 
275V 
X2 
IEC 60384-14  
2:nd ed. 
 
*) New Alternative component 
 
 
MAX OVERALL UNCERTAINTY 
Report reference No. 520081
 
Electrical quantities 
   Max 
overall 
uncertainty 
 
 
 
 
Voltage 
0 - 1 V 
DC 
+/- 1,5% +/- 1 mV 
 
1 - 1000 V 
DC 
+/- 1,5% 
 
> 1000 V 
DC 
+/- 5% 
 
0 - 1 V  RMS 
45 Hz - 5 kHz 
+/- 1,5% +/- 1 mV 
 
1 - 1000 V  RMS 
45 Hz - 5 kHz 
+/- 1,5% 
 
> 1000 V  RMS 
45 Hz - 5 kHz 
+/- 5% 
 
 
 
 
Current 
< 10 A 
DC 
+/- 1,5% 
 
> 10 A 
DC 
+/- 2,5% 
 
< 2 A 
45 Hz - < 2kHz 
+/- 1,5% 
 
< 2 A 
2 - 5 kHz 
+/- 2,5% 
 
2 - 10 A 
45 Hz - 5 kHz 
+/- 2,5% 
 
> 10 A 
30 - 1000 Hz 
+/- 5% 
 
 
 
 
Resistance 
< 100 m
Ω 
 +/- 
5% 
 
100m
Ω - 2 MΩ 
 +/- 
1% 
 
> 2 M
Ω 
 +/- 
5% 
 
 
 
 
Electric power 
100 mW - 10 kW 
DC, 40 Hz - 10 kHz 
+/- 1,5% 
 
 
 
 
Oscilloscopes  (peak value) 
 
 
+/- 5% 
 
 
 
 
Earth continuity meters 
 
 
+/- 10% 
 
 
 
 
Leakage current 
< 30 mA 
50 - 60 Hz 
+/- 3,5% 
 
> 30 mA 
50 - 5000 Hz 
+/- 5% 
 
Non-electrical quantities 
   Max 
overall 
uncertainty 
 
 
 
 
Temperature 
< 100° C 
 
+/- 3° C 
 
100 - 500° C 
 
+/- 3% 
 
 
 
 
Linear dimensions 
< 2mm 
 
+/- 0,05 mm 
 
2 - 150 mm 
 
+/- 0,1 mm 
 
> 150 mm 
 
+/- 0,25% 
 
 
 
 
Gauge rods 
< 2mm 
 
+/- 0,02 mm 
 
 
 
 
Mass 
< 10 g 
 
+/- 0,5% 
 
10 g - 100 g 
 
+/- 1% 
 
> 100 g 
 
+/- 2% 
 
 
 
 
Relative 
humidity 
  +/- 
5% 
 
 
 
 
Force 
  +/- 
10% 
 
 
 
 
Torque 
  +/- 
10% 
 
 
 
 
Pressure 
  +/- 
10% 
 
 
 
 
Timers 
< 1 ms 
 
+/- 1 ms 
 
1 s - 1 min 
 
+/- 1 s 
 > 
min 
 +/- 
10 
 
 
 
MAX OVERALL UNCERTAINTY 
Report reference No. 520081
 
Electrical quantities 
   Max 
overall 
uncertainty 
 
 
 
 
Voltage 
0 - 1 V 
DC 
+/- 1,5% +/- 1 mV 
 
1 - 1000 V 
DC 
+/- 1,5% 
 
> 1000 V 
DC 
+/- 5% 
 
0 - 1 V  RMS 
45 Hz - 5 kHz 
+/- 1,5% +/- 1 mV 
 
1 - 1000 V  RMS 
45 Hz - 5 kHz 
+/- 1,5% 
 
> 1000 V  RMS 
45 Hz - 5 kHz 
+/- 5% 
 
 
 
 
Current 
< 10 A 
DC 
+/- 1,5% 
 
> 10 A 
DC 
+/- 2,5% 
 
< 2 A 
45 Hz - < 2kHz 
+/- 1,5% 
 
< 2 A 
2 - 5 kHz 
+/- 2,5% 
 
2 - 10 A 
45 Hz - 5 kHz 
+/- 2,5% 
 
> 10 A 
30 - 1000 Hz 
+/- 5% 
 
 
 
 
Resistance 
< 100 m
Ω 
 +/- 
5% 
 
100m
Ω - 2 MΩ 
 +/- 
1% 
 
> 2 M
Ω 
 +/- 
5% 
 
 
 
 
Electric power 
100 mW - 10 kW 
DC, 40 Hz - 10 kHz 
+/- 1,5% 
 
 
 
 
Oscilloscopes  (peak value) 
 
 
+/- 5% 
 
 
 
 
Earth continuity meters 
 
 
+/- 10% 
 
 
 
 
Leakage current 
< 30 mA 
50 - 60 Hz 
+/- 3,5% 
 
> 30 mA 
50 - 5000 Hz 
+/- 5% 
 
Non-electrical quantities 
   Max 
overall 
uncertainty 
 
 
 
 
Temperature 
< 100° C 
 
+/- 3° C 
 
100 - 500° C 
 
+/- 3% 
 
 
 
 
Linear dimensions 
< 2mm 
 
+/- 0,05 mm 
 
2 - 150 mm 
 
+/- 0,1 mm 
 
> 150 mm 
 
+/- 0,25% 
 
 
 
 
Gauge rods 
< 2mm 
 
+/- 0,02 mm 
 
 
 
 
Mass 
< 10 g 
 
+/- 0,5% 
 
10 g - 100 g 
 
+/- 1% 
 
> 100 g 
 
+/- 2% 
 
 
 
 
Relative 
humidity 
  +/- 
5% 
 
 
 
 
Force 
  +/- 
10% 
 
 
 
 
Torque 
  +/- 
10% 
 
 
 
 
Pressure 
  +/- 
10% 
 
 
 
 
Timers 
< 1 ms 
 
+/- 1 ms 
 
1 s - 1 min 
 
+/- 1 s 
 > 
min 
 +/- 
10 
 
Page of 7
Display