JBL SUB 200 (serv.man4) EMC - CB Certificate ▷ View online
page 25 of 34
Ref.No.:310127
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
6 D115
( - +)
sc 198 --
Mains
fuse
>2.6A
Mains fuse blew immediately.
No remarks.
7 D110
( - +)
sc 198 --
Mains
fuse
>2.6A
Mains fuse blew immediately.
No remarks.
8 C117 sc 198
--
--
-- P
mains
decreased to 8W.
No hazard.
page 26 of 34
Ref.No.:310127
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14
TABLE: list of critical components and materials
P
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
Mains
Transformer
Transtec
TT0869803320
AC 230-240V
IEC 60065
—
Thermal release
Joint Force
M33
2A, 250V,
130
°C
IEC 60691
TÜV
Mains Fuse
Walter
TSD
T1.25AL 250V
IEC 60127
Mains
fuseholder
Chin Shin
(Walter)
R3-11
10A 250V
IEC 60065
—
IEC 61058-1
Mains switch
Rong Feng Ind.
Co., Ltd
RF-1003 10(4)
8/80A,
250V Class II
IEC60065:98
Annex G
NEMKO
Cordset:
plug
I Sheng
SP-021A
2.5A 250V
CEE 7
cord
H03VVH2-F
2 x 0.75mm²
IEC 60227
UK Cord set:
Plug with fuse
Luen Tai
Electric
9518
13A 250V
BS 1363
BSI
cord Rhythm
Wire
Ind. Co., Ltd.
H03VVH2-F
2 x 0.75mm²
IEC 60227
KEMA
Cord set Korea:
plug
Volex
MP2217
3A 250V
KS C8305
cord
VCTFK
2 x 0.75mm²
KS C3304
Bobbins
Transformer
EI Dupont de
Nemours
Nylon 66
101,101F
94V-2 Complies
with
FH 3-40mm/min
IEC 60707:81
—
Mains fuse
holder
Walter
R3-11
Min. FV 1
IEC 60707
—
Sec. connector
P103
JWT
A3963Wv2-5P
Min. FV 1
IEC 60707
—
PCB Jian
He
(Cheng Ho)
Various
Min. FV 1
IEC 60707
—
X capacitor
across the
mains switch
across the
mains switch
Europtronic
(Taiwan) Ind.
Corp.
MPX 0.10µF,
275V
X2
IEC 60384-14
2:nd ed.
page 27 of 34
Ref.No.:310127
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
GROUP DIFFERENCES (COMMON MODIFICATIONS) TO IEC 60065
CONTENTS
Add the following annexes:
Annex ZB (normative) Special national conditions
Annex ZC (informative) A-deviations
Noted
1.1.1
Replace the text of note 1 by:
NOTE 1 This standard can be used as a guide for
the testing of battery operated apparatus.
the testing of battery operated apparatus.
Noted
3.1 Delete
the
note.
Add the following indent:
-
Exposure to excessive sound pressures from
headphones or earphones
headphones or earphones
NOTE A new method is under consideration by
CENELEC/TC 206
CENELEC/TC 206
Noted
15.1.1
Delete notes 1 and 2.
Add to note 4:
Attention is drawn to the fact that a standard is
under preparation (presently prEN 50074) for
socket-outlets which allow connection of Class II
appliances only.
under preparation (presently prEN 50074) for
socket-outlets which allow connection of Class II
appliances only.
Noted
15.2
Delete note 2.
Noted
16.1
Delete note 1.
Noted
16.2 Delete
the
note.
Noted
20
Delete note 2.
Noted
Annex B
Delete note 2.
Noted
B.5.4.1e)
Delete notes 1 and 2.
Noted
B.8.1
Delete notes 1, 2 and 3.
Noted
B.8.2 Delete
the
note.
Noted
B.14.12
Delete notes 1 and 2.
Noted
Annex G
Delete the note.
Noted
page 28 of 34
Ref.No.:310127
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
Annex P
Bibliography
Add the following notes for the standards
indicated:
indicated:
IEC 60130
NOTE: IEC 60130-9:1989 +
A1: 1993 are harmonized as EN
60130-9
(not
modified).
IEC 60169
NOTE: Parts 23, 24 and25 are
harmonized as Ens (not modified)
IEC 60173
NOTE: Harmonized as HD 27
S1: 1983 (not modified).
IEC 60260
NOTE: Harmonized as HD 98
S1: 1977 (not modified).
IEC 60335-2-56 NOTE: Harmonized as EN 60335-
2-56:1997
2-56:1997
(not
modified).
IEC 61040
NOTE: Harmonized as EN
61040:1992
(not
modified).
IEC 60695
NOTE: Harmonized as EN 60695
series
(not
modified).
Noted