DOWNLOAD JBL SUB 140P (serv.man4) Service Manual ↓ Size: 2.18 MB | Pages: 48 in PDF or view online for FREE

Model
SUB 140P (serv.man4)
Pages
48
Size
2.18 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sub-140p-sm4.pdf
Date

JBL SUB 140P (serv.man4) EMC - CB Certificate ▷ View online

Report No:W-N-1010002-CY-01-1 
                                                                                                   
Telecom Technology Center 
 
33 
 
Red arrow mark for Contact Discharge and Blue arrow mark for Air Discharge 
 
 
 
 
Red arrow mark for Contact Discharge
Report No:W-N-1010002-CY-01-1 
                                                                                                   
Telecom Technology Center 
 
6.7.6 Test Result 
 
Test Mode 
Interference 
Monitor 
Sound 
Picture 
Sub in 
ESD 
Ear 
PASS 
N/A 
LFE ESD  Ear 
PASS 
N/A 
 
34 
Report No:W-N-1010002-CY-01-1 
                                                                                                   
Telecom Technology Center 
 
 
Te  Mode: 
st
Sub in 
Discharge Mode 
charge 
Air 
Contact Dis
Discharg
ESD Voltage 
2 kV 
4 kV 
2 kV 
4 kV 
8 kV 
Points\
t\Polarity + - + - + - + - + - 
Resul
Points 
B B B B A A A A A A 
VCP A 
HCP A 
N/A 
 
 
Test Mode: 
LFE 
Discharge Mode 
Contact Discharge 
Air Discharge 
ESD Voltage 
2 kV 
4 kV 
2 kV 
4 kV 
8 kV 
Points\Result\Polarity + - + - + - + - + - 
Points 
B B B B A A A A A A 
VCP A 
HCP A 
N/A 
 
35 
Report No:W-N-1010002-CY-01-1 
                                                                                                   
Telecom Technology Center 
 
6.8 EFT/BURST TESTING 
6
ficatio
 
Ba
IEC 61000-4-4
 
.8.1 Test Speci
n
 
sic Standard:
 
 
Test Voltage:
 
Power
ne:1
, C xial
ble:
 kV
 Li
 kV
oa
 Ca
0.5
 
Impul
e shape :
 
0 n
se Wav
5/5
s
 
Burst Duration:
 
 ms
15
 
Burst Period:
 
300 ms
 
Test Duration:
 
t le
han 1 min.
 
No
ss t
 
6.8.2 Test Procedure 
uipment, are placed on a table that is 0.8 meter above a metal 
g
ured 1m
m thick min. 
The other condition as following manner: 
a. The length of power cord between the
ing dev
d the E
ould no
rity discharges were applied. 
c. The duration time of e
 test sequential was 1 m
te 
d. For the actual test configuration, please refer to the related Item –EUT Test Photos. 
 
6.8.3 
tion From
es
tan
rd
o deviation
 
 
The EUT and support eq
round plane meas
*1m min. and 0.65m
 coupl
ice an
UT sh
exceed 1 meter. 
b. Both positive and negative pola
ach
inu
Devia
 T t S
da
 
 
N
36 
Page of 48
Display