JBL SPYRO (serv.man3) EMC - CB Certificate ▷ View online
Page 7 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Such parts are considered to
be bare.
be bare.
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
No such parts
N
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used
N
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No liver parts in apparatus
N
8.5
Class I equipment
Powered 18 Vd.c. by certified
adaptor
adaptor
N
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
N
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
N
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
N
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
N
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
N
Separation by Class II isolating transformer
N
Page 8 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
Separation by Class I transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation > 0,4 mm (mm) : - Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
- No live parts in apparatus
N
Reinforced
insulation
> 0,4 mm (mm) .................... :
N
Thin sheet insulation
N
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
N
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
8.11
Detaching of wires
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
N
Vibration
test
carried out ........................................ :
N
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
No mains socket-outlets
N
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
No exclusively be supplied
N
Page 9 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
None N
8.18
Endurance test as required by 8.17
N
8.19
Disconnection from the mains
Powered 18 Vd.c. by certified
adaptor
adaptor
N
8.19.1 Disconnect
device
N
All-pole switch or circuit breaker with >3mm
contact separation
contact separation
N
8.19.2
Mains switch ON indication
N
8.20
Switch not fitted in the mains cord
None
N
8.21
Bridging components comply with clause 14
None
N
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
N
9.1
Testing on the outside
N
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
Discharge not exceeding 45 μC
N
Energy of discharge not exceeding 350 mJ
N
9.1.1.2
Test with test finger and test probe
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
9.1.3
Ventilation holes and other holes tested by means
of 4 mm x 100 mm test pin
of 4 mm x 100 mm test pin
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
N
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
Page 10 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
N
If C is not greater than 0,1 μF no test needed
< 0, 1 uF
P
9.1.7
Enclosure sufficiently resistant to external force
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
Test probe 11 of IEC 61032 for 10 s (50 N)
N
Test hook of fig. 4 for 10 s (20 N)
N
30 mm diameter test tool for 5 s (100 or 250 N) .... :
N
9.2
No hazard after removing a cover by hand
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
10 INSULATION
REQUIREMENTS
N
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
10.2
Humidity treatment 48 h or 120 h ........................... : - Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
- No live parts in apparatus
N
10.3
Insulation resistance and dielectric strength
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
Click on the first or last page to see other SPYRO (serv.man3) service manuals if exist.