Page 35 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
 
NOTE 1- If the enclosure does not withstand the 
glow-wire test the appliance is considered to 
have failed to meet the requirements of Clause 
21.201 without the need for consequential 
testing. 
 N 
 
NOTE 2 - If other parts do not withstand the glow-
wire test due to ignition of the tissue paper and if 
this indicates that burning or glowing particles 
can fall onto an external surface underneath the 
apparatus, the apparatus is considered to have 
failed to meet the requirements of Clause 21.201 
without the need for consequential testing. 
 N 
 
NOTE 3 - Parts likely to be impinged upon by the 
flame are considered to be those within the 
envelope of a vertical cylinder having a radius of 
10 mm and a height equal to the height of the 
flame, positioned above the point of the material 
supporting in contact with, or in close proximity 
to, connections. 
 N 
20.201.2.4  Testing of printed boards 
The base material of printed boards shall be 
subject to the needle-flame test of Clause 
21.201.2.3. The flame shall be applied to the 
edge of the board where the heatsink effect is 
lowest when the board is positioned as in normal 
use. The flame shall not be applied to an edge 
consisting of broken perforations, unless the 
edge is less than 3 mm from a potential ignition 
source.  
The test is not carried out if the - 
 N 
 
- printed board does not carry any potential 
ignition source; 
 N 
 
- base material of printed boards, on which the 
available power at a connection exceeds 15 VA 
operating at a voltage exceeding 50 V and 
equal or less than 400 V (peak) a.c. or d.c. 
under normal operating conditions, is of 
flammability category V-1 or better according to 
AS/NZS 60695.11.10, or the printed boards are 
protected by an enclosure meeting the 
flammability category V-O according to 
AS/NZS 60695.11.10, or made of metal, having 
openings only for connecting wires which fill 
the openings completely; or 
 N 
 
Page 36 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
 
-  base material of printed boards, on which the 
available power at a connection exceeds 15 VA 
operating at a voltage exceeding 400 V (peak) 
a.c. or d.c. under normal operating conditions, 
and base material of printed boards supporting 
spark gaps which provides protection against 
overvoltages, is of flammability category V-O 
according to AS/NZS 60695.11.10 or the 
printed boards are contained in a metal 
enclosure, having openings only for connecting 
wires which fill the openings completely. 
 N 
 
Compliance shall be determined using the 
smallest thickness of the material. 
 N 
 
NOTE - Available power is the maximum power 
which can be drawn from the supplying circuit 
through a resistive load whose value is chosen to 
maximize the power for more than 2 min when 
the circuit supplied is disconnected.  
 N 
21.201.3 
For open circuit voltages greater than 4kV 
potential ignition  sources with open circuit 
voltages exceeding 4 kV (peak) a.c. or d.c. under 
normal operating conditions shall be contained in 
a fire enclosure which shall comply with 
flammability category V-1 or better according to 
AS/NZS 60695.11.10. 
 N 
Annex B 
After the heading add: 
 
 
For Australia only, this Annex is replaced by the 
requirements of the Telecommunications 
Labelling Notice issued under the 
Telecommunications Act. 
NOTE – The Telecommunications Act is 
administered by the Australian Communications 
Authority. 
 Noted 
 
 
Page 37 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
 
 
NATIONAL DIFFERENCES OF CANADA: IEC 60065, 7th Edition (CB Bulletin No. 110A, June 2006) 
 
3.2A 
Add the following clause 
A component power supply complying with 
CAN/CSA – C22.2 No. 60950 is considered to 
comply with this construction and fault conditions 
of this Standard after taking into account any 
relevant conditions of acceptability. 
 N 
4.2 
Normal operating conditions 
See below. 
— 
4.2.1 
Add the following after the fifth paragraph 
For apparatus intended for use at nominal 120Vac 
the apparatus shall comply with this Standard at 
supply voltages between 108V and 125V. For 
apparatus intended for use at nominal 240Vac, the 
apparatus shall comply with this Standard at 
supply voltages between 216V and 250V. 
18 Vdc powered equipment 
4.2.10 
Add the following after the second paragraph 
As an alternative, a supply apparatus for general 
use complying with CAN/CSA – C22.2 No. 223 or 
CAN/CSA – C22.2 No. 60950 shall be acceptable.
 N 
Marking and instructions 
Add the following paragraph 
Adhesive nameplates on commercial products 
shall comply with CSA Standard C22.2 No. 0.15. 
 P 
5.1 
Identification and supply ratings 
Add the following item 
A) date of manufacture: a date or code identifying 
the period of manufacture shall be marked on the 
apparatus; 
Serial No. is marked 
 
Page 38 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
5.3A 
Add the following clause 
Where a loudspeaker grille, removable from the 
outside, is relied on as part of the enclosure (see 
Clause 9.2), the following marking or equivalent 
shall be visible on the enclosure after removal of 
the grille: 
“Caution – To prevent electric shock hazard, 
replace grille.” 
Alternatively, the symbol in Clause 5.2 b) shall be 
visible after removal of the grille, and the caution 
wording above shall appear in the user 
instructions, accompanied by the symbol.  
Compliance is checked by inspection. 
No removal loudspeaker grille. 
Constructional requirements with regard to 
protection against shock 
 
— 
8.9 
Add the following title to this clause 
Mains wiring 
Add the following paragraph 
Wiring in circuits with voltages higher than 42 V 
peak shall comply with CSA C22.2 No. 127 or 
CAN/CSA – C22.2 No. 210.2.  
< 42 V peak 
9.1 
Testing on the outside 
 
— 
9.1.1A 
Class I apparatus leakage 
Add the following clause 
For cord – connected Class I apparatus, the 
leakage current through the safety earthing 
conductor, expressed as voltages U and U, shall 
not exceed U = 105 V (peak) and U = 1.05 V 
(peak) (1.5mA). 1 2 1 2 
Apparatus having a leakage current between 0.75 
mA and 1.5 mA shall be provided with a caution 
label on the mains cord with the following, or 
equivalent: 
“CAUTION – TO REDUCE THE RISK OF 
ELECTRIC SHOCK, GROUNDING OF THE 
CENTRE PIN OF THIS PLUG MUST BE 
MAINTAINED”.  
 N 