Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
NOTE 1- If the enclosure does not withstand the
glow-wire test the appliance is considered to
have failed to meet the requirements of Clause
21.201 without the need for consequential
testing.
glow-wire test the appliance is considered to
have failed to meet the requirements of Clause
21.201 without the need for consequential
testing.
N
NOTE 2 - If other parts do not withstand the glow-
wire test due to ignition of the tissue paper and if
this indicates that burning or glowing particles
can fall onto an external surface underneath the
apparatus, the apparatus is considered to have
failed to meet the requirements of Clause 21.201
without the need for consequential testing.
wire test due to ignition of the tissue paper and if
this indicates that burning or glowing particles
can fall onto an external surface underneath the
apparatus, the apparatus is considered to have
failed to meet the requirements of Clause 21.201
without the need for consequential testing.
N
NOTE 3 - Parts likely to be impinged upon by the
flame are considered to be those within the
envelope of a vertical cylinder having a radius of
10 mm and a height equal to the height of the
flame, positioned above the point of the material
supporting in contact with, or in close proximity
to, connections.
flame are considered to be those within the
envelope of a vertical cylinder having a radius of
10 mm and a height equal to the height of the
flame, positioned above the point of the material
supporting in contact with, or in close proximity
to, connections.
N
20.201.2.4 Testing of printed boards
The base material of printed boards shall be
subject to the needle-flame test of Clause
21.201.2.3. The flame shall be applied to the
edge of the board where the heatsink effect is
lowest when the board is positioned as in normal
use. The flame shall not be applied to an edge
consisting of broken perforations, unless the
edge is less than 3 mm from a potential ignition
source.
subject to the needle-flame test of Clause
21.201.2.3. The flame shall be applied to the
edge of the board where the heatsink effect is
lowest when the board is positioned as in normal
use. The flame shall not be applied to an edge
consisting of broken perforations, unless the
edge is less than 3 mm from a potential ignition
source.
The test is not carried out if the -
N
- printed board does not carry any potential
ignition source;
N
- base material of printed boards, on which the
available power at a connection exceeds 15 VA
operating at a voltage exceeding 50 V and
equal or less than 400 V (peak) a.c. or d.c.
under normal operating conditions, is of
flammability category V-1 or better according to
AS/NZS 60695.11.10, or the printed boards are
protected by an enclosure meeting the
flammability category V-O according to
AS/NZS 60695.11.10, or made of metal, having
openings only for connecting wires which fill
the openings completely; or
operating at a voltage exceeding 50 V and
equal or less than 400 V (peak) a.c. or d.c.
under normal operating conditions, is of
flammability category V-1 or better according to
AS/NZS 60695.11.10, or the printed boards are
protected by an enclosure meeting the
flammability category V-O according to
AS/NZS 60695.11.10, or made of metal, having
openings only for connecting wires which fill
the openings completely; or
N
Page 36 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
- base material of printed boards, on which the
available power at a connection exceeds 15 VA
operating at a voltage exceeding 400 V (peak)
a.c. or d.c. under normal operating conditions,
and base material of printed boards supporting
spark gaps which provides protection against
overvoltages, is of flammability category V-O
according to AS/NZS 60695.11.10 or the
printed boards are contained in a metal
enclosure, having openings only for connecting
wires which fill the openings completely.
operating at a voltage exceeding 400 V (peak)
a.c. or d.c. under normal operating conditions,
and base material of printed boards supporting
spark gaps which provides protection against
overvoltages, is of flammability category V-O
according to AS/NZS 60695.11.10 or the
printed boards are contained in a metal
enclosure, having openings only for connecting
wires which fill the openings completely.
N
Compliance shall be determined using the
smallest thickness of the material.
smallest thickness of the material.
N
NOTE - Available power is the maximum power
which can be drawn from the supplying circuit
through a resistive load whose value is chosen to
maximize the power for more than 2 min when
the circuit supplied is disconnected.
which can be drawn from the supplying circuit
through a resistive load whose value is chosen to
maximize the power for more than 2 min when
the circuit supplied is disconnected.
N
21.201.3
For open circuit voltages greater than 4kV
potential ignition sources with open circuit
voltages exceeding 4 kV (peak) a.c. or d.c. under
normal operating conditions shall be contained in
a fire enclosure which shall comply with
flammability category V-1 or better according to
AS/NZS 60695.11.10.
voltages exceeding 4 kV (peak) a.c. or d.c. under
normal operating conditions shall be contained in
a fire enclosure which shall comply with
flammability category V-1 or better according to
AS/NZS 60695.11.10.
N
Annex B
After the heading add:
For Australia only, this Annex is replaced by the
requirements of the Telecommunications
Labelling Notice issued under the
Telecommunications Act.
requirements of the Telecommunications
Labelling Notice issued under the
Telecommunications Act.
NOTE – The Telecommunications Act is
administered by the Australian Communications
Authority.
administered by the Australian Communications
Authority.
Noted
Page 37 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
NATIONAL DIFFERENCES OF CANADA: IEC 60065, 7th Edition (CB Bulletin No. 110A, June 2006)
3.2A
3.2A
Add the following clause
A component power supply complying with
CAN/CSA – C22.2 No. 60950 is considered to
comply with this construction and fault conditions
of this Standard after taking into account any
relevant conditions of acceptability.
CAN/CSA – C22.2 No. 60950 is considered to
comply with this construction and fault conditions
of this Standard after taking into account any
relevant conditions of acceptability.
N
4.2
Normal operating conditions
See below.
—
4.2.1
Add the following after the fifth paragraph
For apparatus intended for use at nominal 120Vac
the apparatus shall comply with this Standard at
supply voltages between 108V and 125V. For
apparatus intended for use at nominal 240Vac, the
apparatus shall comply with this Standard at
supply voltages between 216V and 250V.
the apparatus shall comply with this Standard at
supply voltages between 108V and 125V. For
apparatus intended for use at nominal 240Vac, the
apparatus shall comply with this Standard at
supply voltages between 216V and 250V.
18 Vdc powered equipment
N
4.2.10
Add the following after the second paragraph
As an alternative, a supply apparatus for general
use complying with CAN/CSA – C22.2 No. 223 or
CAN/CSA – C22.2 No. 60950 shall be acceptable.
use complying with CAN/CSA – C22.2 No. 223 or
CAN/CSA – C22.2 No. 60950 shall be acceptable.
N
5
Marking and instructions
Add the following paragraph
Adhesive nameplates on commercial products
shall comply with CSA Standard C22.2 No. 0.15.
shall comply with CSA Standard C22.2 No. 0.15.
P
5.1
Identification and supply ratings
Add the following item
A) date of manufacture: a date or code identifying
the period of manufacture shall be marked on the
apparatus;
the period of manufacture shall be marked on the
apparatus;
Serial No. is marked
P
Page 38 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
5.3A
Add the following clause
Where a loudspeaker grille, removable from the
outside, is relied on as part of the enclosure (see
Clause 9.2), the following marking or equivalent
shall be visible on the enclosure after removal of
the grille:
outside, is relied on as part of the enclosure (see
Clause 9.2), the following marking or equivalent
shall be visible on the enclosure after removal of
the grille:
“Caution – To prevent electric shock hazard,
replace grille.”
replace grille.”
Alternatively, the symbol in Clause 5.2 b) shall be
visible after removal of the grille, and the caution
wording above shall appear in the user
instructions, accompanied by the symbol.
visible after removal of the grille, and the caution
wording above shall appear in the user
instructions, accompanied by the symbol.
Compliance is checked by inspection.
No removal loudspeaker grille.
N
8
Constructional requirements with regard to
protection against shock
protection against shock
—
8.9
Add the following title to this clause
Mains wiring
Add the following paragraph
Wiring in circuits with voltages higher than 42 V
peak shall comply with CSA C22.2 No. 127 or
CAN/CSA – C22.2 No. 210.2.
peak shall comply with CSA C22.2 No. 127 or
CAN/CSA – C22.2 No. 210.2.
< 42 V peak
N
9.1
Testing on the outside
—
9.1.1A
Class I apparatus leakage
Add the following clause
For cord – connected Class I apparatus, the
leakage current through the safety earthing
conductor, expressed as voltages U and U, shall
not exceed U = 105 V (peak) and U = 1.05 V
(peak) (1.5mA). 1 2 1 2
leakage current through the safety earthing
conductor, expressed as voltages U and U, shall
not exceed U = 105 V (peak) and U = 1.05 V
(peak) (1.5mA). 1 2 1 2
Apparatus having a leakage current between 0.75
mA and 1.5 mA shall be provided with a caution
label on the mains cord with the following, or
equivalent:
mA and 1.5 mA shall be provided with a caution
label on the mains cord with the following, or
equivalent:
“CAUTION – TO REDUCE THE RISK OF
ELECTRIC SHOCK, GROUNDING OF THE
CENTRE PIN OF THIS PLUG MUST BE
MAINTAINED”.
ELECTRIC SHOCK, GROUNDING OF THE
CENTRE PIN OF THIS PLUG MUST BE
MAINTAINED”.
N