JBL SDP-40 HD EMC - CB Certificate ▷ View online
Test Number - 254-05
EN 61000-3-2 TEST LIMITS CONTINUED
3. Class C Harmonic Limits >25W without dimmers:
Harmonic Order
n
Maximum Permissible
harmonic current
A
Odd Harmonics
2
2
3
30
⋅ λ *
5
10
7
7
9
5
11
≤ n ≤ 39
(odd harmonics only)
3
*
λ is the circuit power factor
4. Class D Harmonic Limits:
Harmonic Order
n
Maximum permissible
harmonic current per watt
MA/W
Maximum Permissible
harmonic current
A
3
3.4
2.30
5
1.9
1.14
7
1.0
0.77
9
0.5
0.40
11
0.35
0.33
13
≤ n ≤ 39
(odd harmonics only)
3.85/n
See 1. class A
Page 9 of 18
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax 887 6445
Test Number - 254-05
FLICKER TEST RESULTS
Operating
Voltage 230V
± 2% Single Phase
Operating
Frequency
:
50Hz
± .5%
Total Supply Harmonic Distortion:
Less than 3%
P
lt
Observation Period:
2 hours
P
st
Observation Period:
10 minutes
Measurements are made per section 4.2.1 using a flickermeter.
PLEASE SEE NEXT PAGE(S) FOR FLICKER TEST DATA
Page 10 of 18
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax 887 6445
Test Number - 254-05
Short Term Flicker Data:
test#
Limit
Measured
Result
P
st
1
≤1
0.000 P
P
st
2
≤1
0.000 P
P
st
3
≤1
0.000 P
P
st
4
≤1
0.000 P
P
st
5
≤1
0.000 P
P
st
6
≤1
0.000 P
P
st
7
≤1
0.000 P
P
st
8
≤1
0.000 P
P
st
9
≤1
0.000 P
P
st
10
≤1
0.000 P
P
st
11
≤1
0.000 P
P
st
12
≤1
0.000 P
Long Term Flicker Data:
test
Limit
Measured
Result
P
lt
≤ 0.65
0.000 P
Page 11 of 18
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax 887 6445
Test Number - 254-05
Relative Steady-State Voltage Change Data:
test
Limit
Measured
Result
d
c
≤ 3%
0.000 P
Maximum Relative Voltage Change Data:
test
Limit
Measured
Result
d
max
≤ 4%*
0.213 P
* The relative voltage change may not exceed 3% for more than 200ms.
Page 12 of 18
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax 887 6445