JBL SDP-40 HD (serv.man4) EMC - CB Certificate ▷ View online
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax 887 6445
Page 9 of 143
Test Number- 250-05
EN 55013 TEST LIMITS CONTINUED
3. Disturbance Power Limits for Associated Equipment Only:
Frequency
MHz
Quasi-Peak Limit
dB
µV
Average Limit
dB
µV
30 - 300
62 to 72*
52 to 62*
300 - 1000
under consideration
*Limit converted to dBuV into 50 ohms from dBpW by adding 17dB.
4. Disturbance Voltage at Antenna Terminals Limits:
Equipment type
Source
Frequency
MHz
Limit values
dB(
µ
V) 75
Ω
Quasi-peak
a
Television receivers, video
recorders and PC tuner
cards working in channels
between
30 MHz and 1 GHz
recorders and PC tuner
cards working in channels
between
30 MHz and 1 GHz
Local oscillator
Other
≤
1 000
30
to
950
950
to
2 150
30
to
2 150
Fundamental
46
Harmonics
46
Harmonics
54
46
Television receivers for
broadcast satellite
transmissions and tuner
units
broadcast satellite
transmissions and tuner
units
b
Local oscillator
Other
950
to
2 150
950
to
2 150
30
to
2 150
Fundamental
54
Harmonics
54
46
Frequency modulation
sound receivers and
sound receivers and
PC tuner cards
Local oscillator
Other
≤
1 000
30
to
300
300
to
1 000
30
to
1 000
Fundamental
54
Harmonics
50
Harmonics
52
46
Frequency modulation car
radios
radios
Local oscillator
Other
≤
1 000
30
to
300
300
to
1 000
30
to
1 000
Fundamental
66
Harmonics
59
Harmonics
52
46
Associated equipment with
an RF input, e.g. video tape
player, laser disc player
an RF input, e.g. video tape
player, laser disc player
Other
30
to
2 150
46
a
At frequencies above 1 GHz the peak detector is used.
b
For tuner units, "antenna terminal" means "first intermediate frequency input terminal".
NOTE For AM broadcast receivers for LW, MW and SW no limits apply.
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax 887 6445
Page 10 of 143
Test Number-250-05
TEST FACILITY DESCRIPTION
Compliance Worldwide is located on 357 Main Street in Sandown,
New Hampshire. The EN 55013 / EN 55022 conducted and radiated test
sites, located at C.W. are also used for Federal Communications
Commission (FCC) testing. A site description is on file with the FCC
in Columbia, MD USA.
sites, located at C.W. are also used for Federal Communications
Commission (FCC) testing. A site description is on file with the FCC
in Columbia, MD USA.
The radiated site is 10 meter indoor site with an enclosure for
the product and measurement antenna. The basement below the site is
used for the test equipment, personnel and any support equipment.
used for the test equipment, personnel and any support equipment.
The conducted site is part of a 16' x 20' x 12' ferrite tile
chamber and uses one of the walls for a vertical metal wall required
by the measurement standard.
by the measurement standard.
Both sites are designed to test products or systems 1.5 meter x
1.0 meter, floor standing or table top.
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax 887 6445
Page 11 of 143
Test Number- 250-05
TEST SET UP
AND
PERIPHERAL CONNECTION INFORMATION
Ground Plane
*Note: drawing shows functional interconnections, see following page
for a list of resistor terminated or non-terminated cables connected
to the EUT.
RT-20
HDMI Out
Power
HDMI Out
MC12
HDMI In-1
HDTV
HDMI In
AC Mains
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax 887 6445
Page 12 of 143
Test Number- 250-05
The cables directly connected to this equipment are listed below.
*Note: cables were changed to 6-meter cables for disturbance power
measurements.
*Note: All cables are shielded except the power cord, fiber optics and
trigger outputs.
Cable
No.
No.
Connection Type
Cable Type Length
Terminator
1
Composite Video In 1
75 Ω RCA
1 meter 75 Ω
2
Composite Video In 2
75 Ω RCA
1 meter 75 Ω
3
Composite Video In 3
75 Ω RCA
1 meter 75 Ω
4
Composite Video In 4
75 Ω RCA
1 meter 75 Ω
5
Composite Video In 5
75 Ω RCA
1 meter 75 Ω
6
Component Vid. In 1 Y
75 Ω RCA
1 meter 75 Ω
7
Component Vid. In 1 Pr
75 Ω RCA
1 meter 75 Ω
8
Component Vid. In 1 Pb
75 Ω RCA
1 meter 75 Ω
9
Component Vid. In 2 Y
75 Ω RCA
1 meter 75 Ω
10
Component Vid. In 2 Pr
75 Ω RCA
1 meter 75 Ω
11
Component Vid. In 2 Pb
75 Ω RCA
1 meter 75 Ω
12
Component Vid. In 3 Y
75 Ω RCA
1 meter 75 Ω
13
Component Vid. In 3 Pr
75 Ω RCA
1 meter 75 Ω
14
Component Vid. In 3 Pb
75 Ω RCA
1 meter 75 Ω
15
S-Video In 1
S-Video 4 pin 1 meter 75 Ω x 2
16
S-Video In 2
S-Video 4 pin 1 meter 75 Ω x 2
17
S-Video In 3
S-Video 4 pin 1 meter 75 Ω x 2
18
HDMI In 1
HDMI
1 meter
19
HDMI In 2
HDMI
1 meter
20
HDMI In 3
HDMI
1 meter
21
HDMI In 4
HDMI
1 meter
22
HDMI In 5
HDMI
1 meter
23
HDMI In 6
HDMI
1 meter
24
HDMI Out 1
HDMI
1 meter
25
Analog Audio In 1 L
Audio RCA
1 meter 10 kΩ
26
Analog Audio In 1 R
Audio RCA
1 meter 10 kΩ
27
Analog Audio In 2 L
Audio RCA
1 meter 10 kΩ
28
Analog Audio In 2 R
Audio RCA
1 meter 10 kΩ
29
Analog Audio In 3 L
Audio RCA
1 meter 10 kΩ
30
Analog Audio In 3 R
Audio RCA
1 meter 10 kΩ
31
Analog Audio In 4 L
Audio RCA
1 meter 10 kΩ
32
Analog Audio In 4 R
Audio RCA
1 meter 10 kΩ
Click on the first or last page to see other SDP-40 HD (serv.man4) service manuals if exist.