JBL SDP-40 HD (serv.man4) EMC - CB Certificate ▷ View online

 
 
 
 
 
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
(603) 887 3903 Fax 887 6445 
 
Page 9 of 143
 
Test Number- 250-05 
 
EN 55013 TEST LIMITS CONTINUED 
 
3. Disturbance Power Limits for Associated Equipment Only: 
 
 
Frequency 
MHz 
Quasi-Peak Limit 
dB
µV 
Average Limit 
dB
µV 
 
30 - 300 
 
62 to 72* 
 
52 to 62* 
 
300 - 1000 
 
under consideration 
 
*Limit converted to dBuV into 50 ohms from dBpW by adding 17dB. 
 
 
4.  Disturbance Voltage at Antenna Terminals Limits: 
 
Equipment type
Source
Frequency
MHz
Limit values
dB(
µ
V) 75 
Quasi-peak 
a
Television receivers, video
recorders and PC tuner
cards working in channels
between
30 MHz and 1 GHz
Local oscillator
Other
1 000
30
to
950
950
to
2 150
30
to
2 150
Fundamental
46
Harmonics
46
Harmonics
54
46
Television receivers for
broadcast satellite
transmissions and tuner
units 
b
Local oscillator
Other
950
to
2 150
950
to
2 150
30
to
2 150
Fundamental
54
Harmonics
54
46
Frequency modulation
sound receivers and
PC tuner cards
Local oscillator
Other
1 000
30
to
300
300
to
1 000
30
to
1 000
Fundamental
54
Harmonics
50
Harmonics
52
46
Frequency modulation car
radios
Local oscillator
Other
1 000
30
to
300
300
to
1 000
30
to
1 000
Fundamental
66
Harmonics
59
Harmonics
52
46
Associated equipment with
an RF input, e.g. video tape
player, laser disc player
Other
30
to
2 150
46
a
   At frequencies above 1 GHz the peak detector is used.
b
   For tuner units, "antenna terminal" means "first intermediate frequency input terminal".
 
NOTE   For AM broadcast receivers for LW, MW and SW no limits apply.
 
 
 
 
 
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
(603) 887 3903 Fax 887 6445 
 
Page 10 of 143
Test Number-250-05 
 
 
 
TEST FACILITY DESCRIPTION 
 
 
Compliance Worldwide is located on 357 Main Street in Sandown, 
New Hampshire. The EN 55013 / EN 55022 conducted and radiated test 
sites, located at C.W. are also used for Federal Communications 
Commission  (FCC) testing.  A site description is on file with the FCC 
in Columbia, MD USA.  
 
 
The radiated site is 10 meter indoor site with an enclosure for 
the product and measurement antenna. The basement below the site is 
used for the test equipment, personnel and any support equipment. 
 
 
The conducted site is part of a 16' x 20' x 12' ferrite tile 
chamber and uses one of the walls for a vertical metal wall required 
by the measurement standard.   
 
 
Both sites are designed to test products or systems 1.5 meter x 
1.0 meter, floor standing or table top. 
  
 
 
 
 
 
 
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
(603) 887 3903 Fax 887 6445 
 
Page 11 of 143
Test Number- 250-05 
 
 
TEST SET UP 
AND 
PERIPHERAL CONNECTION INFORMATION 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Ground Plane 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
*Note: drawing shows functional interconnections, see following page 
for a list of resistor terminated or non-terminated cables connected 
to the EUT. 
 
RT-20
           
HDMI Out
                    
 
 
 
 
 
          
   
Power       
 
                                   HDMI Out
  
                                                       
   MC12                                          
                                    HDMI In-1
                                                       
HDTV                           
HDMI In
 
  
      
 
 
 
 
 
AC Mains 
 
 
 
 
 
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
(603) 887 3903 Fax 887 6445 
 
Page 12 of 143
 
 
Test Number- 250-05 
 
The cables directly connected to this equipment are listed below.   
 
*Note: cables were changed to 6-meter cables for disturbance power 
measurements. 
 
*Note: All cables are shielded except the power cord, fiber optics and 
trigger outputs. 
 
Cable 
No. 
Connection Type 
Cable Type  Length 
Terminator 
Composite Video In 1 
75 Ω RCA 
1 meter  75 Ω 
Composite Video In 2 
75 Ω RCA 
1 meter  75 Ω 
Composite Video In 3 
75 Ω RCA 
1 meter  75 Ω 
Composite Video In 4 
75 Ω RCA 
1 meter  75 Ω 
Composite Video In 5 
75 Ω RCA 
1 meter  75 Ω 
Component Vid. In 1 Y 
75 Ω RCA 
1 meter  75 Ω 
Component Vid. In 1 Pr 
75 Ω RCA 
1 meter  75 Ω 
Component Vid. In 1 Pb 
75 Ω RCA 
1 meter  75 Ω 
Component Vid. In 2 Y 
75 Ω RCA 
1 meter  75 Ω 
10 
Component Vid. In 2 Pr 
75 Ω RCA 
1 meter  75 Ω 
11 
Component Vid. In 2 Pb 
75 Ω RCA 
1 meter  75 Ω 
12 
Component Vid. In 3 Y 
75 Ω RCA 
1 meter  75 Ω 
13 
Component Vid. In 3 Pr 
75 Ω RCA 
1 meter  75 Ω 
14 
Component Vid. In 3 Pb 
75 Ω RCA 
1 meter  75 Ω 
15 
S-Video In 1 
S-Video 4 pin 1 meter  75 Ω x 2 
16 
S-Video In 2 
S-Video 4 pin 1 meter  75 Ω x 2 
17 
S-Video In 3 
S-Video 4 pin 1 meter  75 Ω x 2 
18 
HDMI In 1 
HDMI 
1 meter   
19 
HDMI In 2 
HDMI 
1 meter   
20 
HDMI In 3 
HDMI 
1 meter   
21 
HDMI In 4 
HDMI 
1 meter   
22 
HDMI In 5 
HDMI 
1 meter   
23 
HDMI In 6 
HDMI 
1 meter   
24 
HDMI Out 1 
HDMI 
1 meter   
25 
Analog Audio In 1 L 
Audio RCA 
1 meter  10 kΩ 
26 
Analog Audio In 1 R 
Audio RCA 
1 meter  10 kΩ 
27 
Analog Audio In 2 L 
Audio RCA 
1 meter  10 kΩ 
28 
Analog Audio In 2 R 
Audio RCA 
1 meter  10 kΩ 
29 
Analog Audio In 3 L 
Audio RCA 
1 meter  10 kΩ 
30 
Analog Audio In 3 R 
Audio RCA 
1 meter  10 kΩ 
31 
Analog Audio In 4 L 
Audio RCA 
1 meter  10 kΩ 
32 
Analog Audio In 4 R 
Audio RCA 
1 meter  10 kΩ 
Page of 127