JBL SCS 178 Sub (serv.man4) EMC - CB Certificate ▷ View online
File No. F 21063-2-01 HM , Page 5 of 13
MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+49-9424-9407-0 Fax:+49-9424-9407-60 Rev.Nr. 8.3
Conducted Emission
T E S T C O N D I T I O N S A N D R E S U L T S
The measurement of the conducted emissions (interference voltage – A 4)
was performed in a shielded room.
was performed in a shielded room.
o - Test not applicable
Testlocation:
o - Shielded room no. 1
o - Shielded room no. 2
o - Shielded room no. 3
o - Shielded room no. 4
! - Shielded room no. 5
o - Shielded room no. 6
o - Shielded room no. 7
o - Anechoic chamber
o - Full compact chamber
o - Shielded room no. 2
o - Shielded room no. 3
o - Shielded room no. 4
! - Shielded room no. 5
o - Shielded room no. 6
o - Shielded room no. 7
o - Anechoic chamber
o - Full compact chamber
Used test instruments and test accessories please see attachment B
The requirements are
!
!
!
! - MET
O - NOT MET
Min. limit margin
> 5
dB
at
0,15-30 MHz
_______
________
Max. limit exceeding
dB
at
MHz
_______
________
Remarks:
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
File No. F 21063-2-01 HM , Page 6 of 13
MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+49-9424-9407-0 Fax:+49-9424-9407-60 Rev.Nr. 8.3
Radiated Emission
T E S T C O N D I T I O N S A N D R E S U L T S
The measurement of the radiated emissions (electric field – A 5)
in the frequency range of 80 MHz - 1000 MHz was performed in horizontal and vertical antenna
polarisation at a non-reflecting open-site and a testdistance of:
in the frequency range of 80 MHz - 1000 MHz was performed in horizontal and vertical antenna
polarisation at a non-reflecting open-site and a testdistance of:
o - Test not applicable
o - Open-site 1
! - Open-site 2
! - Open-site 2
! - 3 meters
o - 10 meters
o - 30 meters
o - 10 meters
o - 30 meters
Used test instruments and test accessories please see attachment B
The requirements are
!
!
!
! - MET
O - NOT MET
Min. limit margin
> 5
dB
at
80-1000 MHz
_______
________
Max. limit exceeding
dB
at
MHz
_______
________
Remarks:
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
File No. F 21063-2-01 HM , Page 7 of 13
MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+49-9424-9407-0 Fax:+49-9424-9407-60 Rev.Nr. 8.3
Equivalent Radiated Emission
T E S T C O N D I T I O N S A N D R E S U L T S
The measurement of the equivalent radiated emissions (A 9) in the frequency range 1 GHz - 18 GHz was
performed in horizontal and vertical antenna polarisation at a non-reflecting test-site and a testdistance of:
performed in horizontal and vertical antenna polarisation at a non-reflecting test-site and a testdistance of:
! - Test not applicable
Testlocation:
o - Open-site 1
o - Open-site 2
o - Anechoic chamber
o - Full compact chamber
o - Open-site 2
o - Anechoic chamber
o - Full compact chamber
o - 1 meters
o - 3 meters
o - 10 meters
o - 3 meters
o - 10 meters
Used test instruments and test accessories please see attachment B
The requirements are
O - MET
O - NOT MET
Min. limit margin
dB
at
GHz
_______
________
Max. limit exceeding
dB
at
GHz
_______
________
Remarks:
Accdg. to EN 55013/1.2000 the limits above 3 GHz are under consideration.
_______________________________________________________________________
Therefore the E.U.T. wasn't tested above 3 GHz.
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
File No. F 21063-2-01 HM , Page 8 of 13
MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+49-9424-9407-0 Fax:+49-9424-9407-60 Rev.Nr. 8.3
Interference Voltage
T E S T C O N D I T I O N S A N D R E S U L T S
The measurement of the interference voltage (A 6)
at the antenna terminal of receivers was performed in frequency range 30 MHz – 1000/1750 MHz.
at the antenna terminal of receivers was performed in frequency range 30 MHz – 1000/1750 MHz.
! - Test not applicable
Testlocation:
o - Shielded room no. 1
o - Shielded room no. 2
o - Shielded room no. 3
o - Shielded room no. 4
o - Shielded room no. 5
o - Shielded room no. 6
o - Shielded room no. 7
o - Anechoic chamber
o - Full compact chamber
o - Shielded room no. 2
o - Shielded room no. 3
o - Shielded room no. 4
o - Shielded room no. 5
o - Shielded room no. 6
o - Shielded room no. 7
o - Anechoic chamber
o - Full compact chamber
Used test instruments and test accessories please see attachment B
The requirements are
O - MET
O - NOT MET
Min. limit margin
> 5
dB
at
30-1750 MHz
_______
________
Max. limit exceeding
dB
at
MHz
_______
________
Remarks:
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Click on the first or last page to see other SCS 178 Sub (serv.man4) service manuals if exist.