DOWNLOAD JBL SCS 145 Sub Service Manual ↓ Size: 6.19 MB | Pages: 46 in PDF or view online for FREE

Model
SCS 145 Sub
Pages
46
Size
6.19 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
scs-145-sub.pdf
Date

JBL SCS 145 Sub EMC - CB Certificate ▷ View online

 
 
page 21 of 32 
Ref.No.:407362  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
 
 
 
Position of the functional switch (W)  ..................... : - 
 
Operating conditions 
1/8 of the max. non-clipping output power using the pink noise signal acc. to 4.1.6 .  
 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
                254.4 
0.40 
72 
31 
 
Loudspeaker impedance (
Ω) ................................ : 3.4Ω (measured) 
 
 
Several loudspeaker systems 
 
 
Marking of loudspeaker terminals 
(High Level  out/in) 
 
monitored point: 
dT (K) 
Permitted dT (K)  
 * indicates for 
tropical climates. 
Iron core of mains transformer  
43 
— 
Supply cords (Not under mechanical stress) 
20 
60/50* 
PCB  
26 
85/75* 
Inside top of internal plastic cover  
17 
— 
Heat sink, on rear panel 
24 
40/30* 
Rear panel, above heat sink 
25 
40/30* 
Volume control (plastic) 
19 
50/40* 
Top of cabinet 
60/50* 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (ºC)  ................................. : 20 
 
 
Ambient temperature t2 (
°C) ................................. : 21 
 
temperature rise dT of winding: 
R
1
 (
Ω) 
R
2
 (
Ω) 
dT (K) 
permitted 
dT (K) 
insulation 
class 
Transformer Primary vinding 
8.885 
10.565 
47 
85/75* 
Transformer Secondary winding (Yellow) 
0.5635 
0.6646 
45 
85/75* 
Transformer Secondary winding (Red) 
1.0953 
1.2960 
46 
85/75* 
* indicates permitted temperature rise for tropical climates. 
 
 
page 22 of 32 
Ref.No.:407362  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
7.2 
TABLE: softening temperature of thermoplastics 
temperature T of part 
T - normal  
conditions (ºC) 
T - fault  
conditions (ºC) 
T softening 
(ºC) 
Prim. Fuse holder 
<150 
<150 
202 
 
10.3 
TABLE: insulation resistance measurements 
insulation resistance R between: 
R (M
Ω) 
required R (M
Ω) 
Between the poles of the circuit directly connected to the 
supply mains. 
>10 min.2 
Reinforced insulation. 
>10 
min.4 
 
10.3 TABLE: 
electric 
strength 
measurements 
test voltage applied between: 
test voltage (V) 
Breakdown 
Between the poles of the circuit directly connected to the 
supply mains. 
2120V peak 
No 
Reinforced insulation. 
4240V peak 
No 
 
 
 
 
page 23 of 32 
Ref.No.:407362  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0.9 or 1.06 times rated voltage  .......... : 220-240 
 
 
Ambient temperature (
°C) ..................................... : 21 
 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (ºC)  ................................. : 20 
 
 
Ambient temperature t2 (ºC)  ................................. : 21 
 
No
Component 
No. 
Fault  Test voltage
 (V) 
Test  
time 
Fuse No.
Fuse  
current 
(A) 
Result 
1 Max. 
non-
clipping 
output 
power  
(Pink noise) 
— 254.4  4h Mains 
fuse 
0.6 
Pn = 110W. Uout=15.5V (limited 
by the amplifier) 
Measured temp.rises:  
Mains transformer: 
Prim. winding  = 56K 
Sec. windings = 56K 
PCB = 26K 
Rear panel (metal) = 26K 
Heat sink (on rear side) = 24K
 
No remarks. 
2 Q105  sc  198 
--  Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
3 Q107  sc  198 
--  Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
4 C133  sc  198 
--  Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
5a C122  sc  254.4 
--  Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
5b C122  sc  198 
--  Mains 
fuse 
≤2.3A 
Pin=450→260W, Iin=2.3→1.5A 
Printed conductors on the PCB 
were interrupted. When the 
conductors were bridged the 
thermal fuse in the transformer 
opened after 3.5 min.No remarks.
6 D115 
(  - +) 
sc 198  -- 
Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
7 D110 
(  - +) 
sc 198  -- 
Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
8 C117  sc  198 
-- 
-- 
-- P
mains
 decreased to 8W. 
No hazard. 
 
 
page 24 of 32 
Ref.No.:407362  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
14 
TABLE: list of critical components and materials 
Object/part No. 
Manufacturer/ 
trademark 
Type/model 
Technical data 
Standard 
Mark(s) of 
conformity 
Mains 
Transformer 
Transtec 
TT0869803320  AC 230V, 50Hz 
IEC 60065 
— 
Bobbins 
Transformer 
EI Dupont de 
Nemours 
Nylon 66  
101, 101F 
94V-2 Complies 
with 
FH 3-40mm/min 
IEC 60707:81 
— 
Thermal release  Joint Force  
M33 
2A, 250V, 
130
°C 
IEC 60691 
TÜV 
Mains Fuse 
Walter  
TSD 
T1.25AL   250V 
IEC 60127 
 
10A 250V 
IEC 60065 
— 
Mains  
fuse holder 
Chin Shin 
(Walter) 
R3-11 
Min. FV 1 
IEC 60707 
— 
IEC 61058-1 
 
Mains switch 
Rong Feng Ind. 
Co., Ltd 
RF-1003 10(4) 
8/80A, 
250V Class II 
IEC60065:98 
Annex G 
NEMKO 
Sec. connector 
P103 
JWT 
A3963Wv2-5P 
Min. FV 1 
IEC 60707 
— 
PCB Hsiang 
Kou 
07VO 94V-0 
Complies with FV1
 
IEC 60707:81 
— 
cover 
Formosa 
Chemicals & 
Fibre Corp 
ANC100 94V-0 
Complies with 
FH 3-40mm/min 
IEC 60707:81 
— 
Cord set: 
plug 
I Sheng 
 
SP-021A 
 
2.5A   250V 
 
CEE 7 
 
cord 
 
H03VVH2-F 
2 x 0.75mm² 
IEC 60227 
 
Cord set UK: 
Plug with fuse 
Luen Tai 
Electric 
 
9518 
 
13A   250V 
 
BS 1363 
 
BSI 
cord Rhythm 
Wire 
Ind. Co., Ltd. 
 
H03VVH2-F 
 
2 x 0.75mm² 
 
IEC 60227 
 
KEMA 
Cord set Korea: 
plug 
Volex  
MP2217 
 
3A   250V 
 
KS C8305 
 
cord 
 
VCTFK 
2 x 0.75mm² 
KS C3304 
 
Page of 46