Ref.No.:308860  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
 
 
 
Position of the functional switch (W) ...................... : - 
 
Operating conditions 
1/8 of the max. non-clipping output power using the pink noise signal acc. to 4.1.6 .  
 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
                254.4 
0.35 
65 
24 
 
Loudspeaker impedance (
Ω) ................................. : 3.4Ω (measured) 
 
 
Several loudspeaker systems 
 
 
Marking of loudspeaker terminals 
(High Level  out/in) 
 
monitored point: 
dT (K) 
Permitted dT (K) 
Iron core of mains transformer  
49 
— 
Supply cords (Not under mechanical stress) 
29 
60 
PCB  
47 
85 
Inside top of internal plastic cover  
21 
— 
Heat sink, on rear panel 
33 
40 
Rear panel, above heat sink 
32 
40 
Volume control (plastic) 
18 
50 
Top of cabinet 
60 
 
Winding temperature rise measurements 
 
 Ambient 
temperature t1 (ºC) .................................. : 23 
 
 
Ambient temperature t2 (
°C) .................................. : 22 
 
temperature rise dT of winding: 
R
1
 (
Ω) 
R
2
 (
Ω) 
dT (K) 
permitted 
dT (K) 
insulation 
class 
Transformer Primary vinding 
9.152 
11.00 
51 
85 
Transformer Secondary winding (Yellow) 
0.5524 
0.6637 
51 
85 
Transformer Secondary winding (Red) 
1.086 
1.3065 
51 
85 
 
 
page 22 of 30 
Ref.No.:308860  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
7.2 
TABLE: softening temperature of thermoplastics 
temperature T of part 
T - normal  
conditions (ºC) 
T - fault  
conditions (ºC) 
T softening 
(ºC) 
Prim. Fuse holder 
<150 
<150 
202 
 
10.3 
TABLE: insulation resistance measurements 
insulation resistance R between: 
R (M
Ω) 
required R (M
Ω) 
Between the poles of the circuit directly connected to the 
supply mains. 
>10 min.2 
Reinforced insulation. 
>10 
min.4 
 
10.3 
TABLE: electric strength measurements 
test voltage applied between: 
test voltage (V) 
Breakdown 
Between the poles of the circuit directly connected to the 
supply mains. 
2120V peak 
No 
Reinforced insulation. 
4240V peak 
No 
 
 
 
 
page 23 of 30 
Ref.No.:308860  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0.9 or 1.06 times rated voltage ........... : 220-240 
 
 
Ambient temperature (
°C) ...................................... : 22 
 
 
Winding temperature rise measurements 
 
 Ambient 
temperature t1 (ºC) .................................. : 22 
 
 Ambient 
temperature t2 (ºC) .................................. : 22 
 
No
Component 
No. 
Fault  Test voltage 
 (V) 
Test  
time 
Fuse No.
Fuse  
current 
(A) 
Result 
1 Max. 
non-
clipping 
output 
power  
(Pink noise) 
— 254.4  4h Mains 
fuse 
0.6 
Pn = 112W. Uout=15.8V (limited 
by the amplifier) 
Measured temp.rises:  
Mains transformer: 
Prim. winding  = 79K 
Sec. windings = 78K 
PCB = 67K 
Rear panel (metal) = 44K 
Heat sink (on rear side) = 47K
 
No remarks. 
2 Q105  sc  198 
--  Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
3 Q107  sc  198 
--  Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
4 C133  sc  198 
--  Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
5a C122  sc  254.4 
--  Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
5b C122  sc  198 
--  Mains 
fuse 
≤2.3A 
Pin=450→260W, Iin=2.3→1.5A 
Printed conductors on the PCB 
were interrupted. When the 
conductors were bridged the 
thermal fuse in the transformer 
opened after 3.5 min.No remarks.
6 D115 
(  - +) 
sc 198  -- 
Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
7 D110 
(  - +) 
sc 198  -- 
Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
8 C117  sc  198 
-- 
-- 
-- P
mains
 decreased to 8W. 
No hazard. 
 
 
page 24 of 30 
Ref.No.:308860  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
14 
TABLE: list of critical components and materials 
Object/part No. 
Manufacturer/ 
trademark 
Type/model 
Technical data 
Standard 
Mark(s) of 
conformity 
Mains 
Transformer 
Transtec 
TT0869803320  AC 230V, 50Hz 
IEC 60065 
— 
Bobbins 
Transformer 
EI Dupont de 
Nemours 
Nylon 66  
101, 101F 
94V-2 Complies 
with 
FH 3-40mm/min 
IEC 60707:81 
— 
Thermal release  Joint Force  
M33 
2A, 250V, 
130
°C 
IEC 60691 
TÜV 
Mains Fuse 
Walter  
TSD 
T1.25AL   250V 
IEC 60127 
 
10A 250V 
IEC 60065 
— 
Mains  
fuse holder 
Chin Shin 
(Walter) 
R3-11 
Min. FV 1 
IEC 60707 
— 
IEC 61058-1 
 
Mains switch 
Rong Feng Ind. 
Co., Ltd 
RF-1003 10(4) 
8/80A, 
250V Class II 
IEC60065:98 
Annex G 
NEMKO 
Sec. connector 
P103 
JWT 
A3963Wv2-5P 
Min. FV 1 
IEC 60707 
— 
PCB Hsiang 
Kou 
07VO 94V-0 
Complies with FV1
 
IEC 60707:81 
— 
cover 
Formosa 
Chemicals & 
Fibre Corp 
ANC100 94V-0 
Complies with 
FH 3-40mm/min 
IEC 60707:81 
— 
Cord set: 
plug 
I Sheng 
 
SP-021A 
 
2.5A   250V 
 
CEE 7 
 
cord 
 
H03VVH2-F 
2 x 0.75mm² 
IEC 60227 
 
Cord set UK: 
Plug with fuse 
Luen Tai 
Electric 
 
9518 
 
13A   250V 
 
BS 1363 
 
BSI 
cord Rhythm 
Wire 
Ind. Co., Ltd. 
 
H03VVH2-F 
 
2 x 0.75mm² 
 
IEC 60227 
 
KEMA 
Cord set Korea: 
plug 
Volex  
MP2217 
 
3A   250V 
 
KS C8305 
 
cord 
 
VCTFK 
2 x 0.75mm² 
KS C3304 
 