JBL S-5160 (serv.man2) EMC - CB Certificate ▷ View online
File No.
F24989-00-00HM
, page 8 of 31
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
4 T E S T E N V I R O N M E N T
4.1
Address of the test laboratory
MIKES BABT Product Service GmbH
Ohmstrasse
2-4
D - 94342 Strasskirchen
4.2 Environmental
conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:
15-35 ° C
Humidity: 30-60
%
Atmospheric pressure:
86-106 kPa
4.3
Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there may
be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated
for all measurements listed in this test report acc. to CISPR 16-4-2 /11.2003 „Uncertainties, statistics and limit
modelling – Uncertainty in EMC measurements“ and is documented in the MIKES BABT Product Service GmbH
quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar
to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued
compliance of the device.
File No.
F24989-00-00HM
, page 9 of 31
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
5 T E S T C O N D I T I O N S A N D R E S U L T S
5.1 Conducted
disturbance
For test instruments and accessories used see section 6 Part A 4.
5.1.1
Description of the test location
Test location:
Shielded room no. 3
5.1.2
Photo documentation of the test set-up
5.1.3 Test
result
Frequency range:
0.15 MHz - 30 MHz
Min. limit margin
>5 dB at 0.15 - 30 MHz
The requirements are FULFILLED.
Remarks:
For detailed results, please see the following page(s).
File
No.
F24989-00-00HM
, page 10 of 31
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
5.1.4 Test
protocol
Test point
L1
Operation mode:
1 kHz, 1/8 nominal output power
Remarks: n/a
Result: passed
Freq
QP- L
D -Limit
Freq
AV-L
D -Limit
Freq
QP- L
D -Limit
Freq
AV-L
D -Limit
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
150
45,3
20,7 no Result
4000
23,1
32,9
190
37,7
26,3
4675
23
33,0
235
33,7
28,6
6145
13,5
46,5
300
32
28,2
7465
13,7
46,3
430
24,7
32,6
9595
8
52,0
495
37,4
18,7
10710
8,2
51,8
615
45,1
10,9
19180
6,5
53,5
790
37,1
18,9
19800
6,4
53,6
995
40,1
15,9
1180
41,8
14,2
1330
34,9
21,1
1570
36
20,0
1955
30,1
25,9
2405
31,1
24,9
3005
28,6
27,4
dB [µV]
PK:
AV:
QP:
♦
AV:
×
0.15
1
10
20
30 [MHz]
Detector:
Legend
QP LIMIT
AV LIMIT
0
10
20
30
40
50
60
70
80
File
No.
F24989-00-00HM
, page 11 of 31
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
Test point:
N
Operation mode:
1 kHz, 1/8 nominal output power
Remarks: n/a
Result: passed
Freq
QP- L
D -Limit
Freq
AV-L
D -Limit
Freq
QP- L
D -Limit
Freq
AV-L
D -Limit
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
155
38,1
27,6 no Result
3645
39,7
16,3
190
30,9
33,1
4895
29,2
26,8
230
25,3
37,1
6690
24,8
35,2
350
29,8
29,2
7350
24,5
35,5
365
29,7
28,9
8750
24,1
35,9
525
39,8
16,2
10720
19,5
40,5
660
45,1
10,9
14545
11,7
48,3
765
36,3
19,7
18355
13,1
46,9
895
23,5
32,5
20375
8,4
51,6
1205
46,8
9,2
28095
7,2
52,8
1540
50
6,0
1895
45,8
10,2
2025
46,1
9,9
2375
44,6
11,4
2990
38,4
17,6
dB [µV]
PK:
AV:
QP:
♦
AV:
×
0.15
1
10
20
30 [MHz]
Detector:
Legend
QP LIMIT
AV LIMIT
0
10
20
30
40
50
60
70
80
Click on the first or last page to see other S-5160 (serv.man2) service manuals if exist.