CONTENTS
BASIC SPECIFICATIONS . . . . . . . . . . . . . . . . . . . .. . . . . .. . . . . . . . . .. .. . . . . . . .. .. . . . . . . . 2
DETAILED SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . .. .. . . . . . . .. .. . . . . . . . 3
CONTROLS & CONNECTIONS. . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . .. .. . . . . . . .. ..  . . . . . . 4
TROUBLESHOOTING  ……………………... . . . . . . . . . . . . . . . . . . .. . . . . . .. . .. . . . . . . . . …. 5
MECHANICAL/PACKAGING PARTS LIST . . . . . .. . . . . . . . . ……... . . . . . . . . . . . .. . .. . . . … 6
PASSIVE NETWORK SCHEMATIC. . . . . . . . . . . . . . . . . . . . . .. . . . . . . . .  . . . . . . ………….. .7
BLOCK DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. .  .. .. . . . . . . ... 8
PCB DRAWINGS. . . . . . . . . . . …. . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. .  .. .. . . . . . . ...9
ELECTRICAL PARTS LIST. . . . . . . . . . . . . . . . . . . . . .. …….. . . . . . . . .. .. . . . . . . .. .. . . . . . ..12
SCHEMATIC DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. ……………………………..16
PS1400 Powered Subwoofer
General specifications
Amplifier Power Output
400 Watts
Sensitivity (2.83V/1m)
91dB
Frequency Response (–6dB)
28Hz to 130Hz
   (-3dB)
30Hz to 130Hz
Crossover Frequency
130Hz
Low-Frequency Transducer
LE14H-3    14" Aquaplas™-cone woofer
Dimensions (H x W x D)
19" x 20" x 15"  (483mm x 508mm x 381mm)
Plus grille and spike feet
Weight
80 lb (36kg)
JBL continually strives to update and improve existing products, as well as create new ones. The specifications and details in
this and related JBL publications are therefore subject to change without notice.
2
PS1400 SUB Amplifier Detailed Specs
LINE VOLTAGE
Yes/No
Hi/Lo Line
Nom.
Unit
Notes
US 120vac/60Hz
Yes
108-132
120
Vrms
Normal Operation
EU 230vac/50-60Hz
Yes
207-264
230
Vrms
Normal operation, MOMS required
Parameter
Specification
Unit
QA Test 
Limits
Conditions
Notes
Type (Class AB, D, other)
D
n/a
D
Bridge amplifier, None of the speaker outputs 
must be connected to GND at any time.
Load Impedance (speaker)
6
Ohms
6
Rated Output Power  (120VAC)
250
Watts
240
Nominal Input voltage , unit without limiter must 
be able to provide output power levels in the 
range of 350 Watts
THD @ Rated Power
0.3
%
1
THD @ 1 Watt
0.1
%
0.3
DC Offset
100
mV-DC
100
Damping factor
>40
DF
23
200 Watts into 6 Ohms, measured at speaker 
out
Input Sensitivity
Input Frequency
60
Hz
LFE input
1.50
Vrms
±2dB
250 Watts into rated impedance load Normal Mode
SYSTEM INPUT
1.10
Vrms
±2dB
1 Watt output  , LF level control FCW Normal Mode
SYSTEM INPUT
3.47
Vrms
±2dB
1 Watt output  , LF level control FCCWNormal Mode
Signal to Noise
SNR-No Filter
86
dBr
70
relative to rated power
No filter 500 KHz BW AP
SNR-A-Weighted
95
dBA
80
relative to rated power
A-Weighting filter
SNR-unweighted
95
dBr
80
relative to rated power
22k filter
SNR rel. 1W-unweighted
70
dBr
60
relative to 1W Output
22k filter
Residual Noise Floor
1
mVrms
2
Volume @max, using RMS reading 
DMM/VOM (or A/P) BW=20 Khz.
Residual Noise Floor
1.5 mVrms(max)
2
Volume @max, w/ A/P Swept 
Bandpass Measurement (Line freq.+ 
harmonics) (BW=20 Khz)
Input Impedance
Low Level input(LFE)
20K
Ohms
n/a
Nominal
Speaker/Hi Level Input
10K
Ohms
n/a
Nominal
Filters
Normal Mode LP 3rd Order        
-3dB Point
Fixed-selectable
Hz
100 ± 2
Front panel switch to Normal mode 
Reference level 0dB @ 60 Hz 
Normal mode
Separated mode LP 3rd 
Order   -3db Point
Fixed-selectable
Hz
280 ± 2
Front panel switch to Separated 
Reference level 0dB @ 60 Hz,  when 
EQ switch in Normal mode
Subsonic Filter -3dB point
Fixed
Hz
20.5 ± 2
Ref level 0dB ref at 60 Hz Normal 
mode
Limiter 
THD at Max. Output Power
n/a
n/a
functional  Maximum Output Power
Maximum THD as a result of limiting. Must be 
lower than 10%
Signal Sensing (ATO)
Auto-Turn-On (yes/no)
YES
functional 
ATO Input test frequency
60
Hz
functional 
"
ATO Level LFE Input
6
mV
functional 
"
Maximum acceptable level.
ATO Level Speaker in
184
mV
functional 
"
Maximum acceptable level.
ATO Turn-on time
1
sec.
functional  Amp connected and AC on, then 
input signal applied
Auto Mute/ Turn-OFF Time
15
Minutes
15
T before muting, after signal is 
removed
Auto turn of time (T)   must be  5 > T < 15 
Minutes
Power on Delay time
3
sec.
4
AC Power Applied
Transients/Pops
ATO Transient
5
mV-peak
n/a
@ Speaker Outputs
Turn-on Transient
50
mV-peak
2V-pp
@ Speaker Outputs
AC Line cycled from OFF to ON
Turn-off Transient
50
mV-peak
2V-pp
@ Speaker Outputs
AC Line cycled from ON to OFF
Efficiency
70
%
65
Nominal Line voltage 120 VAC
15
Watts
18
@ nom. line voltage
Power Cons. @ rated power
425
Watts
462
@ nom. line voltage
300 Watts @ 6 Ohms nominal line voltage
Protection
Short Circuit Protection 
YES
functional  Direct short at output
Amplifier should resume operation after short 
circuit condition removal 
Thermal Protection 
YES
functional @1/8 max unclipped Power at 1.06 
times the input voltage
DC Offset Protection
YES
-
DC present at Speaker Out leads
Line Fuse Rating
USA-Domestic  
4
Amps
Type-T or Slo Blo-250 V
EU
2
Amps
Type-T or Slo Blo-250 V
External fuse with UL/SEMKO rated holder
3
4
Subwoofer Controls PS1400
¡
¡ On/Auto Switch – When
left in the “Auto” position, the
PS1400 subwoofer will
automatically turn on or go into
standby mode, depending on
whether it detects an audio
signal. When no signal is being
sent, the PS1400 will remain in
standby mode. When it senses
an audio signal, it will
automatically turn itself on and
begin playing. If the PS1400
does not sense a signal for
about twenty minutes, it will
switch itself into standby
mode. When this switch is 
left in the “On” position, the
PS1400 will remain on, whether
or not program material is
playing.
™ LF Crossover Switch – This
switch is used to engage the
PS1400’s internal crossover
when it is stacked with the
PT800 tower module, and when
no external crossover is being
used. In the “Normal” position,
the internal crossover is
engaged, and provides an
electronic 130Hz crossover for
the subwoofer which precisely
matches the passive 130Hz
crossover point of the output
terminal to the PT800. The
crossover is precision-
designed to create a smooth,
integrated floorstanding
speaker system when the
PS1400 and PT800 are stacked.
In the “Separated” position,
the PS1400 provides an
electronic 300Hz rolloff for the
subwoofer, which should be
augmented by the low-pass
crossover in the external
audio/video receiver or
processor. In this mode, the
PT800, whether or not it is
stacked with the PS1400,
should be given only a high-
passed amplifier signal. That
signal should be crossed over
at 80Hz.
£
£ LF Level Control – This
control allows you to adjust the
level of the subwoofer within a
range of +/– 5dB. Start with the
control positioned at 0dB,
which is flat (neutral bass
level). If bass response is
unsatisfactory, due to either
your room acoustics or as a
matter of taste, experiment
with this control until the
desired bass level is achieved. 
This control only affects all
information being received by
the speaker-level input.
¢
¢ Polarity (Phase) Switch 
Use the “Normal” position
whenever the PS1400 and PT800
are stacked and the internal
crossover is used. It should
also be used when an external
crossover is used and all
amplifier channels are in phase.
The “Reverse” position may be
used when the PS1400 and
PT800 are separated, and due
to wave cancellation, bass
response is improved in this
position. “Reverse” may also
be selected when different
amplifiers are used that 
have different polarity
configurations.
PERFORMANCE
SERIES
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
“WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.”
“AVERTISSEMENT: POUR PRÉVENIR LES RISQUES D’INCENDIE OU
DE CHOC ELECTRIQUE, EVITER D’EXPOSER CET APPAREIL A LA
PLUIE OU A L’HUMIDITE.”
MANUAL
AUTO
ON/OFF
SEPARATED
NORMAL
-2             0
-5             5
LF CROSSOVER
REVERSE
NORMAL
MIN                         MAX
–              +
POLARITY
ON
OFF
POWER
LFE LEVEL
SYSTEM INPUT
LFE /SUBWOOFER
INPUT
LF LEVEL
®
NRTL/C
CSA 22-2
UL 1492
PN 336609-001
¡
£
¢
§
dB
Page of 18
Display

JBL PS 1400 Service Manual ▷ Download

  • DOWNLOAD JBL PS 1400 Service Manual ↓ Size: 2.24 MB | Pages: 18 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the JBL PS 1400 in PDF for free, which will help you to disassemble, recover, fix and repair JBL PS 1400 Audio. Information contained in JBL PS 1400 Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.