JBL ON TOUR XTB (serv.man6) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 - Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Error! Reference
source not
found.
Harman Multimedia - On Tour XTB - RTTE Test Report
2009 11138368 EMC
51 of 73
Template 7-09aal
5.7. Electrical Fast Transient Burst Immunity Test Results
Client Harman
Multimedia
Temperature
21
°C
Quote #
12076-3
Relative Humidity
44
%
EUT Name
Bluetooth Portable Loudspeaker
Barometric Pressure 101.4
kPa
EUT Model
On Tour XTB
Test Location
West Ground Plane 1
Governing Doc
EN 301 489-1
Test Engineer
Alan Laudani
Basic Standard
EN 61000-4-4
Date
8-12-08
Test Level:
Test
Voltage: 230VAC 50Hz
AC / DC Mains / Control Ports
X 0.5kV
X 1.0kV
2.0kV
4.0kV
______
Signal
Ports
0.25kV 0.5kV 1.0kV
2.0kV ______
Test Duration:
X 61
sec
_______
Test Equipment
Asset # Used Calibration
Done Calibration
Due
Haefely P90.1 Generator
416
Haefely 093 506.1 Clamp
417
NCR
NCR
Haefely FP-EFT Generator 32.1
689
Multi-Generator EMC Partner TRA2000 845
X
11-Jun-08
10-Jun-09
Performance Criteria:
X A
B
C
Direct Injection Output Path
Test Level
Polarity
(+/-)
L1 L2 PE
Comments
1.0 kV
+/-
X
No susceptibility noted.
1.0 kV
+/-
X
1.0 kV
+/-
X
X
Cable Description (Clamp Injection)
0.5kV +/-
0.5kV +/-
0.5kV +/-
0.5kV +/-
0.5kV +/-
Comments:
Compliant X
Non-Compliant
Photo
X
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 - Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Error! Reference
source not
found.
Harman Multimedia - On Tour XTB - RTTE Test Report
2009 11138368 EMC
52 of 73
Template 7-09aal
5.8.
Power Line Surge Immunity Test Results
Client Harman
Multimedia
Temperature
21
°C
PAN #
12076-3
Relative Humidity
44
%
EUT Name
Bluetooth Portable Loudspeaker
Barometric Pressure
101.4 kPa
EUT Model
On Tour XTB
Test Location
Enclosure 2
Governing Doc
EN 301 489-1
Test Engineer
Alan Laudani
Basic Standard
EN 61000-4-5
Date
8-12-08
Test Equipment: Asset
# Used Calibration
Done Calibration
Due
Haefely PSurge 4010
687
X
13-Aug-08
13-Aug-09
Haefely FP Surge 32.1
688
NCR
NCR
Haefely PC6 288.1
413
Haefely FP Surge 16.1
412
NCR
NCR
Multi-Generator EMC Partner
TRA2000
TRA2000
845
EUT Power:
X 230VAC @ 50Hz
X 230VAC @ 50Hz
400VAC @ 50 Hz
120VAC @ 60 Hz
208VAC @ 60 Hz
Number of Strikes per Polarity/Voltage/Angle:
5
5 5 5
Waveform Generator Type:
X Combination
Ring
X Combination
Ring
Wave
Performance Criteria:
B EUT functions as intended.
L - Gnd
0.5kV (Level 1)
1.0kV (Level 2)
2.0kV (Level 3)
4.0kV (Level 4)
??kV (Special)
L - L
0.25kV (Level 1)
0.5kV (Level 2)
1.0kV (Level 3)
2.0kV (Level 4)
??kV (Special)
Level 1
Level 2
Level 3
Level 4
Special
CM
DM
CM
DM
CM
DM CM
DM
CM
DM
0.5kV
0.25kV
1.0kV
0.5kV
2.0kV
1.0kV
4.0kV
2.0kV
+ - + - + - + - + - + - + - + - + - + -
N–Gnd
L1–Gnd
N-L1
X X
X X
X X
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 - Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Error! Reference
source not
found.
Harman Multimedia - On Tour XTB - RTTE Test Report
2009 11138368 EMC
53 of 73
Template 7-09aal
Compliant X
Non-Compliant
Photo
X
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 - Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Error! Reference
source not
found.
Harman Multimedia - On Tour XTB - RTTE Test Report
2009 11138368 EMC
54 of 73
Template 7-09aal
5.9.
RF Conducted Common Mode Disturbance Immunity Test Results
Client Harman
Multimedia
Temperature
22
°C
Quote #:
12076-3
Relative Humidity
36
%
EUT Name
Bluetooth Portable Loudspeaker
Barometric Pressure
101.6
kPa
EUT Model
On Tour XTB
Test Location
West Ground Plane 2
Governing Doc
EN 301 489-1
Test Engineer
Alan Laudani
Basic Standard
EN 61000-4-6
Date
November 30, 2009
EUT Voltage
230 VAC 50Hz
Test Level:
X 3Vrms
10Vrms
Modulation:
None (CW)
X 80%AM @ 1kHz
Frequency Range:
X 0.15 – 80 MHz
0.15-230MHz
Step:
X 1%
10%
1.5 x 10¯³ /decade
Performance Criteria:
X A
B
1 Injection Point
AC MAINS
Injection Method:
Clamp
X CDN
Comments:
2 Injection Point
Injection Method:
Clamp
CDN
Comments:
3 Injection Point
Injection Method:
Clamp
CDN
Comments:
4 Injection Point
Injection Method:
Clamp
CDN
Comments:
5 Injection Point
Injection Method:
Comments:
Test Equipment Used
Asset #
X if Used Calibration
Done Calibration
Due
HP 8462B (Signal Generator)
751
HP 8648B (Signal Generator)
746
HP 8657A (Signal Generator)
948
X
11/11/2009
11/11/2010
Boonton 4232A (RF Power Meter)
718
X
11/17/2009
11/17/2010
Boonton 51013A (RF Power Sensor)
719
X
11/17/2009
11/17/2010
Werlatone, Directional Coupler
878
X
3/4/2009
3/4/2010
FCC-801-M1-25 (CDN)
473
FCC-801-M2-25 (CDN)
472
FCC-801-M3-25 (CDN)
466
X
8/10/2009
8/10/2010
FCC-801-M3-25 (CDN)
846
FCC-801-M4-25 (CDN)
628
FCC-801-M5-25 (CDN)
629
FCC-801-T2 (CDN)
626
FCC-801-T4 (CDN)
627
AR 2500L (Amplifier)
739
NCR
NCR
EIN 3100L (Amplifier)
913
X
NCR
NCR
Solar 9144-1N (Clamp)
436
NCR
NCR
Solar 9121-1N (Clamp)
435
NCR
NCR
Solar 6741-1N (Clamp)
144
NCR
NCR
Compliant X
Non-Compliant
Photo X
Click on the first or last page to see other ON TOUR XTB (serv.man6) service manuals if exist.