DOWNLOAD JBL ON TOUR XT (serv.man6) Service Manual ↓ Size: 453.95 KB | Pages: 27 in PDF or view online for FREE

Model
ON TOUR XT (serv.man6)
Pages
27
Size
453.95 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-tour-xt-sm6.pdf
Date

JBL ON TOUR XT (serv.man6) EMC - CB Certificate ▷ View online

12/05/2006
Report Number: 3109671ATL-005
Issued:
Intertek
Measurement of immunity to electrical transients (EN 55020 - Sec. 5.6)
5.0
Test
Point
pos
neg
pos
neg
pos
neg
pos
neg
pos
neg
Power  L
A
A
A
A
B(1)
B(1)
--
--
--
--
Power  N
A
A
A
A
B(1)
B(1)
--
--
--
--
Input Voltage: 230VAC, 50Hz
Ambient Temperature:
21
o
C
Ground Strap used: Yes
Relative Humidity: 50%
EFT observed on oscilloscope: Yes
Atmospheric Pressure: 972mbar
0.5kV
Test level, polarity, and result classification
1kHz Tone
1 kV
2 kV
4 kV
Mode of operation
0.25kV
Notes:
EUT has a 2 line only Wall Wort, no protected earth.
Note 1: + or -1kV causes a disruption in sound and volume of EUT. Sound disruption ceases at 
termination of interference.
Data:
Page 9 of 27
EMC Report for  Harman Consumer Group on the JBL On Tour II
12/05/2006
Report Number: 3109671ATL-005
Issued:
Intertek
Measurement of immunity to induced voltages (EN 55020 - Sec. 5.7)
6.0
Method:
Figure 8 of EN 55020 shows the measuring circuit and set-up for receivers, video tape and audio equipment.
The wanted test signal is supplied via the respective connections A or V or S or T (see table 21 of EN 55020 ) by generators G1, G2, G3 and G4 (see table 
22 of EN 55020). The unwanted signal is supplied by generator G5. Network RCi matches the RF disturbance source to the input impedance of the relevant 
audio terminal and a similar network RCo is used to match the output terminals. A mains stopfilter MSF is used to inject the unwanted signal at the mains 
terminal and acts as a stopfilter for unwanted signals from the mains network.
The equipment under test is placed 0.1 m above the centre of a metal ground plane of dimensions 2 m by 1 m. The mains lead shall be bundled to a length 
less than 0.3 m and connected in the shortest possible way to the mains stop filter MSF.
The cable supplying the RF voltage to the audio input and output terminals of the equipment under test shall be of a coaxial type with a transfer impedance of 
50 m /m at a maximum at 30 MHz.
In case the terminals of the equipment under test are non-shielded (e.g. loudspeaker terminals) the connection from the coaxial cable to the terminals shall 
be kept as short as possible. The shield of the coaxial cable shall be connected to the metal plate, as close as possible to the terminals of the coupling unit 
and by a connection as short as possible.
To avoid ground loop problems (e.g. hum, RF coupling) it is recommended that measuring instruments such as audio power meter and signal generators are 
of the ungrounded type.
Alternatively the instruments may each be powered via individual mains isolation transformers.
For connection to the phono or tape input, care shall be taken to ensure an efficient shielding against mains pick-up. The earth conductors of the cable at the 
signal generator output and of the networks RCo, RCi and MSF are connected to the metal plate.
As a rule the connecting cables shall be of the 50   coaxial type, up to the terminal under test (e.g. also for loudspeaker and headphone ports).
The unused input terminals and the loudspeaker and/or headphone or any other audio output terminals are terminated with appropriate load resistors as 
specified by the manufacturer or in the relevant standard.
For stereo or two channel sound television equipment respectively the unwanted signal is simultaneously fed to the two audio input channels. The output 
terminals of the channels are fed as well as measured separately.
Prior to measurements a check shall be carried out to see that no interference signal penetrates directly into the measuring equipment.
The audio output power levels are measured according to 5.2.2 of EN 55020.
In table 22 of EN 55020 the conditions for the measurement are given for receivers, video tape and audio equipment. The wanted signals are specified 
according to the operating mode of the equipment under test and provided by generators G3 and G1, or G4 and G2 and G1 or G1 or G2.
The unwanted signal shall be amplitude modulated with 1 kHz at 80 % depth, supplied by generator G5.
Measurement procedure
For adjusting, the wanted signals are set, dependent on the type of equipment under test and its operating mode, by making the connections of figure 8 as 
follows:
A for audio terminals,
V for video terminals (simultaneously audio signal at audio terminals),
S for antenna terminals (sound broadcast signal) and
T for antenna terminals (television broadcast signal).
The audio controls of the equipment under test, other than the volume control, are set at normal position. The volume control is adjusted to obtain an audio 
output power of 50 mW (or 500 mW) (see 5.2.2 for audio power measuring arrangements).
For stereo equipment the balance control shall be adjusted to obtain 50 mW (or 500 mW) from both channels. The video controls of the equipment under 
test are set to obtain a picture as described in 5.2.3.
For the measurement the unwanted signal is applied to the terminal under test by making the connections of figure 8 as follows:
Ai for audio input terminals,
M for the mains lead and
Ao for audio output terminals.
The connections L, R, respectively Lo, Ro, are for adjusting and/or measurement of the adequate output channels.
For television receivers and video tape equipment in the RF recording mode, measurements are carried out with the wanted signal at the frequency of the 
middle channel of the lowest band available in the equipment under test (or the lowest of the available channels 04, 08, 25 or 55 for system L).
Description:
Manufacturer:
Model:
Asset Number:
Cal Date:
Cal Due:
Test Equipment Used:
AC Millivoltmeter / Measuring Amplifier
B&K
2610
213203
10/26/2006
10/26/2007
Amplifier, Wideband RF Power
Kalmus
747LC-CE
213031
11/03/2003
VBU
Page 10 of 27
EMC Report for  Harman Consumer Group on the JBL On Tour II
12/05/2006
Report Number: 3109671ATL-005
Issued:
Intertek
Measurement of immunity to induced voltages (EN 55020 - Sec. 5.7)
6.0
Description:
Manufacturer:
Model:
Asset Number:
Cal Date:
Cal Due:
Test Equipment Used:
Ditizing Oscilloscope
Tektronix
TDS-540
213179
03/02/2006
03/02/2007
EN 55020 Mains Filter (230V/50Hz/16A)
Erika Feidler
"MSF"
200052
VBU
VBU
EN 55020 Matching Network
Intertek
"RCi"
200051
VBU
VBU
Signal Generator
Fluke
6082A
213020
08/29/2006
08/29/2007
Results:  The sample tested was found to Comply.
Test set up
Photo:
Page 11 of 27
EMC Report for  Harman Consumer Group on the JBL On Tour II
12/05/2006
Report Number: 3109671ATL-005
Issued:
Intertek
Measurement of immunity to induced voltages (EN 55020 - Sec. 5.7)
6.0
Signal to Noise Ratio
150.0K
15.1M
30.1M
45.1M
60.1M
75.1M
90.1M
105.0M
120.0M
135.0M
150.0M
Frequency
-70.0
-60.0
-50.0
-40.0
-30.0
-20.0
-10.0
0
10.0
N
o
is
e
 rel
a
ti
v
e
 t
o
 wa
n
ted
 s
ig
n
a
l,
 d
B
Job Number: 3109671
Company: Harmon
Mode: Audio
Test Port: Mains In
Monitor Port: Speaker
EUT: - Portable Speaker System
M/N: - JBL On-Tour II
S/N: - Prototype
SNR Limit (EN55020)
Noise from EUT
Scan plot mains in
Plot:
Page 12 of 27
EMC Report for  Harman Consumer Group on the JBL On Tour II
Page of 27
Display

Click on the first or last page to see other ON TOUR XT (serv.man6) service manuals if exist.