JBL ON TOUR XT (serv.man3) EMC - CB Certificate ▷ View online
EMC Report for Harman Model JBL On Tour XT
File: 3109671LAX-009 Revision 1
File: 3109671LAX-009 Revision 1
Page 21 of 27
Disturbance Power Prescan – Power Line (with AC 100 VAC 50 Hz)
Disturbance Power Prescan – Power Line (with AC 100 VAC 60 Hz)
Intertek Testing Serv ices
Disturbance Power Emissions 30 MHz - 300 MHz
CISPR 13, Power Main 100 VAC 50 Hz
10.0M
100.0M
1.0G
Frequency (Hz)
0
10.0
20.0
30.0
40.0
50.0
60.0
A
m
pl
it
ude
(
d
B
p
W
)
Company: Harman
Description: Loudspeaker
Model Number: JBL OnTourII
09:40:47 AM, Tuesday, November 21, 2006
Operator: ML
Test Mode: Audio In
Temperature: 23 C
Humidity: 48 %
Peak Scan
Average Limit
Quasi Peak Limit
Average Limit
Quasi Peak Limit
Intertek Testing Serv ices
Disturbance Power Emissions 30 MHz - 300 MHz
CISPR 13, Power Main 100 VAC 60 Hz
10.0M
100.0M
1.0G
Frequency (Hz)
0
10.0
20.0
30.0
40.0
50.0
60.0
A
m
pl
it
ude
(
d
B
p
W
)
Company: Harman
Description: Loudspeaker
Model Number: JBL OnTourII
09:45:36 AM, Tuesday, November 21, 2006
Operator: ML
Test Mode: Audio In
Temperature: 23 C
Humidity: 48 %
Peak Scan
Average Limit
Quasi Peak Limit
Average Limit
Quasi Peak Limit
EMC Report for Harman Model JBL On Tour XT
File: 3109671LAX-009 Revision 1
File: 3109671LAX-009 Revision 1
Page 22 of 27
Disturbance Power Prescan – USB Line
Disturbance Power Prescan – Audio In Line
Intertek Testing Serv ices
Disturbance Power Emissions 30 MHz - 300 MHz
CISPR 13, USB cable
10.0M
100.0M
1.0G
Frequency (Hz)
0
10.0
20.0
30.0
40.0
50.0
60.0
A
m
pl
it
ude
(
d
B
p
W
)
Company: Harman
Description: Loudspeaker
Model Number: JBL OnTourII
10:19:35 AM, Tuesday, November 21, 2006
Operator: ML
Test Mode: Audio In
Temperature: 23 C
Humidity: 48 %
Peak Scan
Average Limit
Quasi Peak Limit
Average Limit
Quasi Peak Limit
Intertek Testing Serv ices
Disturbance Power Emissions 30 MHz - 300 MHz
CISPR 13, Audio In cable
10.0M
100.0M
1.0G
Frequency (Hz)
0
10.0
20.0
30.0
40.0
50.0
60.0
A
m
pl
it
ude
(
d
B
p
W
)
Company: Harman
Description: Loudspeaker
Model Number: JBL OnTourII
10:46:23 AM, Tuesday, November 21, 2006
Operator: ML
Test Mode: Audio In
Temperature: 23 C
Humidity: 48 %
Peak Scan
Average Limit
Quasi Peak Limit
Average Limit
Quasi Peak Limit
EMC Report for Harman Model JBL On Tour XT
File: 3109671LAX-009 Revision 1
File: 3109671LAX-009 Revision 1
Page 23 of 27
4.3.4 Disturbance Power Test Configuration Photograph.
EMC Report for Harman Model JBL On Tour XT
File: 3109671LAX-009 Revision 1
File: 3109671LAX-009 Revision 1
Page 24 of 27
4.4 Disturbance Voltage at Antenna Terminal.
4.4.1 Site and Test Description
Testing was performed in accordance with CISPR 13.
When measurements are made at the antenna terminals of the EUT, a signal generator shell be used to feed
the EUT with a standard test signal.
The Antenna Terminals of the EUT and the Signal Generator are connected to the measuring receiver by
means of coaxial cables and the resistive combining network having a minimum attenuation of 6 dB.
The Impedance seen from the EUT shall be equal to the nominal Antenna input impedance for which the
EUT has been designed. If the output impedance of the signal generator and the input impedance of the
measuring receiver differ from the value, additional matching network and/or attenuators of minimum
value of 6 dB shall be inserted.
4.4.2 Test Block Diagram:
4.4.1 Site and Test Description
Testing was performed in accordance with CISPR 13.
When measurements are made at the antenna terminals of the EUT, a signal generator shell be used to feed
the EUT with a standard test signal.
The Antenna Terminals of the EUT and the Signal Generator are connected to the measuring receiver by
means of coaxial cables and the resistive combining network having a minimum attenuation of 6 dB.
The Impedance seen from the EUT shall be equal to the nominal Antenna input impedance for which the
EUT has been designed. If the output impedance of the signal generator and the input impedance of the
measuring receiver differ from the value, additional matching network and/or attenuators of minimum
value of 6 dB shall be inserted.
4.4.2 Test Block Diagram:
EUT
Combining
Network
Signal Generator
EMI Receiver
Click on the first or last page to see other ON TOUR XT (serv.man3) service manuals if exist.