3.4 VOLTAGE FLUCTUATION AND FLICKERS
3.4.1 LIMITS OF VOLTAGE FLUCTUATION AND FLICKERS
3.4.1 LIMITS OF VOLTAGE FLUCTUATION AND FLICKERS
3.4.1.1TEST PROCEDURE
a. Harmonic Current Test:
Test was performed according to the procedures specified in Clause 5.0 of IEC555-2 and/or
Sub-clause 6.2 of IEC/EN 61000-3-2 depend on which standard adopted for compliance
measurement.
b. Fluctuation and Flickers Test:
Tests was performed according to the Test Conditions/Assessment of Voltage Fluctuations
specified in Clause 5.0/6.0 of IEC555-3 and/or Clause 6.0/4.0 of IEC/EN 61000-3-3 depend on
which standard adopted for compliance measurement.
c. All types of harmonic current and/or voltage fluctuation in this report are assessed by direct
measurement using flicker-meter.
a. Harmonic Current Test:
Test was performed according to the procedures specified in Clause 5.0 of IEC555-2 and/or
Sub-clause 6.2 of IEC/EN 61000-3-2 depend on which standard adopted for compliance
measurement.
b. Fluctuation and Flickers Test:
Tests was performed according to the Test Conditions/Assessment of Voltage Fluctuations
specified in Clause 5.0/6.0 of IEC555-3 and/or Clause 6.0/4.0 of IEC/EN 61000-3-3 depend on
which standard adopted for compliance measurement.
c. All types of harmonic current and/or voltage fluctuation in this report are assessed by direct
measurement using flicker-meter.
3.4.1.2 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 2.3 Unless otherwise a special
operating condition is specified in the follows during the testing.
The EUT tested system was configured as the statements of 2.3 Unless otherwise a special
operating condition is specified in the follows during the testing.
3.4.1.3 TEST SETUP
Page 54 of 106 Report No.: NTEK-2011NT1009314E
3.4.2 TEST RESULTS
EUT:
AM/FM radio & speaker dock
for ipod/iphone
for ipod/iphone
Model Name :
Jbl on time™ micro
Temperature:
25 ℃
Relative Humidity: 45%
Pressure:
1010 hPa
Test Date :
2011-10-17
Test Mode :
Audio in
Test Power :
DC 12V From Adapter AC 230V/50Hz
M
M
a
a
x
x
i
i
m
m
u
u
m
m
F
F
l
l
i
i
c
c
k
k
e
e
r
r
r
r
e
e
s
s
u
u
l
l
t
t
s
s
EUT values
Limit
Result
Pst 0.028
1.00
PASS
Plt 0.028
0.65
PASS
dc [%]
0.005
3.30
PASS
dmax [%]
0.251
4.00
PASS
dt [s]
0.000
0.50
PASS
Page 55 of 106 Report No.: NTEK-2011NT1009314E
4. EMC IMMUNITY TEST
4.1 GENERAL PERFORMANCE CRITERIA
According to EN 55020 standard, the general performance criteria as following:
Criterion A
The equipment shall continue to operate as intended without operator
intervention. No degradation of performance or loss of function is allowed below
a performance level specified by the manufacturer when the equipment is used
as intended.
The performance level may be replaced by a permissible loss of
performance. If the minimum performance level or the permissible performance
loss is not specified by the manufacturer, then either of these may be derived
from the product description and documentation, and by what the user may
reasonably expect from the equipment if used as intended.
intervention. No degradation of performance or loss of function is allowed below
a performance level specified by the manufacturer when the equipment is used
as intended.
The performance level may be replaced by a permissible loss of
performance. If the minimum performance level or the permissible performance
loss is not specified by the manufacturer, then either of these may be derived
from the product description and documentation, and by what the user may
reasonably expect from the equipment if used as intended.
Criterion B
After the test, the equipment shall continue to operate as intended without
operator intervention. No degradation of performance or loss of function is
allowed, after the application of the phenomena below a performance level
specified by the manufacturer, when the equipment is used as intended.
The
performance level may be replaced by a permissible loss of performance.
During the test, degradation of performance is allowed. However, no change of
operating state or stored data is allowed to persist after the test.
operator intervention. No degradation of performance or loss of function is
allowed, after the application of the phenomena below a performance level
specified by the manufacturer, when the equipment is used as intended.
The
performance level may be replaced by a permissible loss of performance.
During the test, degradation of performance is allowed. However, no change of
operating state or stored data is allowed to persist after the test.
Criterion C
Loss of function is allowed, provided the function is self-recoverable, or can be
restored by the operation of the controls by the user in accordance with the
manufacturer’s instructions.
Functions, and/or information stored in non-volatile memory, or protected by a
battery backup, shall not be lost.
restored by the operation of the controls by the user in accordance with the
manufacturer’s instructions.
Functions, and/or information stored in non-volatile memory, or protected by a
battery backup, shall not be lost.
4.2 GENERAL PERFORMANCE CRITERIA TEST SETUP
The EUT tested system was configured as the statements of 2.3 Unless otherwise a special
operating condition is specified in the follows during the testing.
operating condition is specified in the follows during the testing.
Page 56 of 106 Report No.: NTEK-2011NT1009314E
4.3 ESD TESTING
4.3.1 TEST SPECIFICATION
Basic Standard:
IEC/EN 61000-4-2
Discharge Impedance:
330 ohm / 150 pF
Required Performance
B
Discharge Voltage:
Air Discharge:2kV/4kV/8kV (Direct)
Contact Discharge:2kV/4kV (Direct/Indirect)
Contact Discharge:2kV/4kV (Direct/Indirect)
Polarity:
Positive & Negative
Number of Discharge:
Air Discharge: min. 20 times at each test point
Contact Discharge: min. 200 times in total
Contact Discharge: min. 200 times in total
Discharge Mode:
Single Discharge
Discharge Period:
1 second minimum
4.3.2 TEST PROCEDURE
The test generator necessary to perform direct and indirect application of discharges to the EUT in
the following manner:
a. Contact discharge was applied to conductive surfaces and coupling planes of the EUT.
During the test, it was performed with single discharges. For the single discharge time
between successive single discharges was at least 1 second. The EUT shall be exposed to at
least 200 discharges, 100 each at negative and positive polarity, at a minimum of four test
points. One of the test points shall be subjected to at least 50 indirect discharges to the center
of the front edge of the horizontal coupling plane. The remaining three test points shall each
receive at least 50 direct contact discharges.
If no direct contact test points are available, then at least 200 indirect discharges shall be
applied in the indirect mode. Test shall be performed at a maximum repetition rate of one
discharge per second.
Vertical Coupling Plane (VCP):
The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and positioned at a
distance 0.1m from, the EUT, with the Discharge Electrode touching the coupling plane.
The four faces of the EUT will be performed with electrostatic discharge.
Horizontal Coupling Plane (HCP):
The coupling plane is placed under to the EUT. The generator shall be positioned vertically at
a distance of 0.1m from the EUT, with the Discharge Electrode touching the coupling plane.
The four faces of the EUT will be performed with electrostatic discharge.
between successive single discharges was at least 1 second. The EUT shall be exposed to at
least 200 discharges, 100 each at negative and positive polarity, at a minimum of four test
points. One of the test points shall be subjected to at least 50 indirect discharges to the center
of the front edge of the horizontal coupling plane. The remaining three test points shall each
receive at least 50 direct contact discharges.
If no direct contact test points are available, then at least 200 indirect discharges shall be
applied in the indirect mode. Test shall be performed at a maximum repetition rate of one
discharge per second.
Vertical Coupling Plane (VCP):
The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and positioned at a
distance 0.1m from, the EUT, with the Discharge Electrode touching the coupling plane.
The four faces of the EUT will be performed with electrostatic discharge.
Horizontal Coupling Plane (HCP):
The coupling plane is placed under to the EUT. The generator shall be positioned vertically at
a distance of 0.1m from the EUT, with the Discharge Electrode touching the coupling plane.
The four faces of the EUT will be performed with electrostatic discharge.
b. Air discharges at insulation surfaces of the EUT.
It was at least ten single discharges with positive and negative at the same selected point.