REPORT  # 56050AF 
 1 3   
3.   OCCUPIED BANDWIDTH – PER ANSI C63.4 ANNEX I.6 
3.1  Test Setup and Procedure 
The Test Site and EUT were set up as described in section 2.1 of this document. 
The EUT is put into the operational test mode as stated in Section 1.4 and then 
started. The spectrum analyzer had its self-calibration performed, and then set to 
the frequency to be tested, with a bandwidth of 10kHz as per ANSI C63.4 Annex 
I.6 paragraph b. The Max Peak of the Fundamental Frequency was noted, and the 
points 20 dB dB below the Fundamental Max Peak, for both sides of the signal 
was noted, and the frequency difference between these points was recorded as 
the occupied bandwidth. See below for example.  
 
Example Of Occupied Bandwidth Measurement 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3.2  Occupied Bandwidth Test Data.  
Frequency 
(MHz) 
Measured 
Bandwidth 
Bellow 
Fundamental 
Polarity 
Instrument 
Bandwidth 
Required 
Occupied 
Bandwidth 
Result 
Comments 
433.9  
68.4 kHz 
20dB 
Vertical 
10kHz 
1.085 MHz 
Pass 
 
433.9  
62.7 kHz 
20dB 
Horizontal 
10kHz 
1.085 MHz 
Pass 
 
 
Refer to section 3.3 for Test Data 
20dB 
Occupied 
20dB Points 
20dB Points 
Max Peak of Fundamental 
Instrumentation Bandwidth set as described in ANSI C63.4 Annex I.6 
REPORT  # 56050AF 
 1 4   
3.3  Occupied Bandwidth  
 
Vertical 
 
 
Horizontal 
 
REPORT  # 56050AF 
 1 5   
4.  APPENDIX SECTION 
 
4.1  APPENDIX A:  UNCERTAINTY TOLERANCE 
 
DNB Engineering’s Utah Facility is within acceptable uncertainty tolerances per ANSI C63.4 
sections 5.4.6.1 and 5.4.6.2 as well as CISPR 16-1 Annex M, section M.2. 
 
ANSI C63.4  
 
5.4.6.1 Site Attenuation. A measurement site shall be considered acceptable for radiated 
electromagnetic field measurements if the horizontal and vertical NSA derived from 
measurements, i.e., the “measured NSA,” are within +4 dB of the theoretical NSA 
(5.4.6.3) for an ideal site. 
 
5.4.6.1 NSA Tolerance. The +4 dB tolerance in 5.4.6.1 includes instrumentation 
calibration errors, measurement technique errors, and errors due to site anomalies.  
These errors are analyzed in ANSI C63.6-[3], wherein it is shown that the performance 
of a well-built site contributes only 1 dB of the total allowable tolerance. 
 
CISPR 16-1  
 
M.2  Error analysis 
 
. . . The total estimated errors are the basis for the + 4 dB site acceptability criterion 
consisting of approximately 3 dB measurement uncertainties and an additional allowable 
1 dB for site imperfections. 
4.2  APPENDIX B:  SITE CHARACTERISTICS,  
CHALK CREEK EMI TEST SITE
 
The DNB Engineering test facility is located in Chalk Creek Canyon near Coalville, Utah.  
Site characteristics were measured according to the procedures outlined in ANSI C63.4 
“Characteristics of Open Field Test Site”.  The results of these characterizations indicate 
that the Chalk Creek site is an outstanding facility to perform accurate and repeatable 
EMI tests. 
 
4.2.1  Ambient Emissions 
 
Ambient Emission measurements were made to determine the level of the ambient 
emanations at the DNB test facility.  The results indicate that all ambient signals are 
below the FCC Radiated Emission limits or that each can easily be identified as an 
ambient signal. 
 
REPORT  # 56050AF 
 1 6   
 
4.2.2  FCC Certification 
 
Page of 19