JBL ON STAGE (serv.man5) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
57 of 80
7.7. Electrical Fast Transient Burst Immunity Test Results
Client
Harman Multimedia
Temperature
75
deg F
PAN #
24-310-HAR
Relative Humidity
46
%
EUT Name
Speaker System
Barometric Pressure
30.32
Hg
EUT Model
JBL OnStage
Test Location
Enclosure 1
Governing Doc
EN 55024
Test Engineer
Rodel Resolme
Basic Standard
EN 61000-4-4
Date
05/21/04
Test Level:
AC / DC Mains / Control Ports
0.5kV
X
1.0kV
2.0kV
4.0kV
______
Signal Ports
0.25kV
0.5kV
1.0kV
2.0kV
______
Test Duration:
X
61 sec
_______
Test Equipment
Asset #
Used
Calibration Done
Calibration Due
Haefely P90.1 Generator
416
X
07/23/03
07/23/04
Haefely 093 506.1 Clamp
417
NCR
NCR
Haefely FP-EFT Generator 32.1
689
Noiseken FNS-100L
547
Noiseken 15-00001A Clamp
802
NCR
NCR
Performance Criteria:
A
X
B
C
Direct Injection Output Path
Test Level
Polarity
(+/-)
L1
L2
PE
Comments
1.0kV
+/-
X
1.0kV
+/-
X
1.0kV
+/-
X
1.0kV
+/-
X
X
1.0kV
+/-
X
X
1.0kV
+/-
X
X
1.0kV
+/-
X
X
X
+/-
Coupling Clamp: SCSI Cable
+/-
Coupling Clamp: CAT5 Cable
+/-
Coupling Clamp: Serial Cable
+/-
Coupling Clamp: USB Cable
Cable Description (Clamp Injection)
Polarity
Compliant X
Non-Compliant
Photo
X
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
58 of 80
7.8. Power Line Surge Immunity Test Results
Client
Harman Multimedia
Temperature
75
deg F
PAN #
24-310-HAR
Relative Humidity
46
%
EUT Name
Speaker System
Barometric Pressure
30.32
Hg
EUT Model
JBL OnStage
Test Location
Enclosure 1
Governing Doc
EN 55024
Test Engineer
Rodel Resolme
Basic Standard
EN 61000-4-5
Date
May 21, 2004
EUT Power:
Number of Strikes per Polarity/Voltage:
Repetition #
Angle
X 230VAC @ 50Hz
X
Five (5)
1
0º
230/400VAC @ 50 Hz
Twenty (20)
2
90º
120VAC @ 60 Hz
3
180º
4
270º
5
360º
Waveform Generator Type:
Ring Wave
Combination
Test Equipment:
Asset #
Used
Calibration Done
Calibration Due
Haefely PSurge 4010
687
X
11/18/03
11/18/04
Haefely FP Surge 32.1
688
X
NCR
NCR
Haefely PC6 288.1
413
Haefely FP Surge 16.1
412
NCR
NCR
Performance Criteria:
X
A
B
C
L - Gnd
0.5kV (Level 1)
1.0kV (Level 2)
X 2.0kV (Level 3)
4.0kV (Level 4)
??kV (Special)
L - L
0.25kV (Level 1)
0.5kV (Level 2)
X 1.0kV (Level 3)
2.0kV (Level 4)
??kV (Special)
Level 1
Level 2
Level 3
Level 4
Special
CM
DM
CM
DM
CM
DM
CM
DM
CM
DM
0.5kV
0.25kV
1.0kV
0.5kV
2.0kV
1.0kV
4.0kV
2.0kV
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
N–Gnd
X
X
L1–Gnd
X
X
N-L1
X
X
Compliant
X
Non-Compliant
Photo
X
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
59 of 80
7.9. RF Conducted Common Mode Disturbance Immunity Test Results
Client
Harman Multimedia
Temperature
74
deg C
PAN #
24-310-HAR
Relative Humidity
43
%
EUT Name
Speaker System
Barometric Pressure
30.23
Hg
EUT Model
JBL OnStage
Test Location
West Ground Plane
Governing Doc
EN 55024
Test Engineer
Rodel Resolme
Basic Standard
EN 61000-4-6
Date
May 25, 2004
Test Level:
X
3Vrms
10Vrms
Modulation:
None (CW)
X
80%AM @ 1kHz
Frequency Range:
X
0.15 – 80 MHz
0.15-230MHz
Step:
X
1%
10%
1.5 x 10¯³ /decade
Performance Criteria:
X
A
B
1
Injection Point (Cable)
AC Mains
Injection Method:
Clamp
X
CDN
Comments:
2
Injection Point (Cable)
Injection Method:
Clamp
CDN
Comments:
3
Injection Point (Cable)
Injection Method:
Clamp
CDN
Comments:
4
Injection Point (Cable)
Injection Method:
Comments:
5
Injection Point (Cable)
Injection Method:
Comments:
Test Equipment Used
Asset #
X if Used
Calibration Done
Calibration Due
HP 8462B (Signal Generator)
751
Fluke 6060B (Signal Generator)
212
HP 8648B (Signal Generator)
746
X
08/25/03
08/25/04
FCC-801-M1-25 (CDN)
473
FCC-801-M2-25 (CDN)
472
FCC-801-M3-25 (CDN)
466
X
01/13/04
01/13/05
FCC-801-M4-25 (CDN)
628
FCC-801-M5-25 (CDN)
629
FCC-801-T2 (CDN)
626
FCC-801-T4 (CDN)
627
AR 10A250 (Amplifier)
402
X
NCR
NCR
IFI 1500 (Amplifier)
571
NCR
NCR
RF Power Labs (Amplifier)
397
NCR
NCR
Solar 9144-1N (Clamp)
436
Solar 9121-1N (Clamp)
435
Solar 6741-1N (Clamp)
144
Compliant X
Non-Compliant
Photo X
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
60 of 80
7.10. Voltage Dips and Interruptions Immunity Test Results
Client
Harman Multimedia
Temperature
74
deg F
PAN #
24-310-HAR
Relative Humidity
44
%
EUT Name
Speaker System
Barometric Pressure
30.21
Hg
EUT Model
JBL OnStage
Test Location
West Ground Plane
Governing Doc
EN 55024
Test Engineer
Rodel Resolme
Basic Standard
EN 61000-4-11
Date
05/24/04
EUT Voltage:
X
230VAC @ 50Hz
120VAC @ 60Hz
Equipment Used
Used
Asset #
Cal Done
Cal Due
California Instruments AC Power
X
604
NCR
NCR
Xitron 2520 Standard Impedance
581
Xitron 2503AH Power Analysis System
582
Changes Occur At:
Zero Crossing
Voltage Dips
Criteria
Compliance
% Reduction
Duration sec/period
A
B
C
Yes
No
X >95%
10msec / 0.5
X
X
30%
10msec / 0.5
X
X
X 30%
500msec / 25
60%
100 msec / 5
Not Required
Voltage Interruptions
Criteria
Compliance
% Reduction
Duration sec/period
A
B
C
Yes
No
X >95%
5000msec / 250
X
X
100%
20msec / 1.0
Not Required
Photo
X
Click on the first or last page to see other ON STAGE (serv.man5) service manuals if exist.