JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online
Page 6 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
1.7
Marking and instructions
1.7.1 Power
rating
P
Rated voltage(s) or voltage range(s) (V) ............ : 100
− 240 Vac
P
Symbol for nature of supply, for d.c. only............ : The EUT is supplied by AC
mains
N/A
Rated frequency or rated frequency range (Hz) : 50 / 60 Hz
P
Rated
current
(mA
or A) ..................................... : 0.5 A
P
Manufacturer’s name or trademark or
identification mark .............................................. :
identification mark .............................................. :
LEI P
Type/model or type reference ............................. : MU15-C******-**
P
Symbol of for Class II equipment only ............... :
P
Other
symbols
....................................................: Symbols are used according to
IEC 60417-1
P
Certification
marks ............................................. :
N/A
1.7.2
Safety instructions
The English “I.T.E. POWER
SUPPLY” will be provided with
the unit
SUPPLY” will be provided with
the unit
P
1.7.3
Short duty cycles
The EUT is continuous
operating type
operating type
N/A
1.7.4
Supply voltage adjustment ................................. : Only one power supply voltage
range
N/A
1.7.5
Power outlets on the equipment ........................ : No such components within the
EUT
N/A
1.7.6 Fuse
identification .............................................. : The “F1” and “T1AL250V” are
marked adjacent to the main
fuse
fuse
P
1.7.7
Wiring terminals
Class II equipment
N/A
1.7.7.1 Protective
earthing
and bonding terminals ........ :
N/A
1.7.7.2
Terminal for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8 Controls
and
indicators
No
controls or indicators within
the EUT
N/A
1.7.8.1 Identification,
location and marking .................... :
N/A
Page 7 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
1.7.8.2 Colours .............................................................. :
N/A
1.7.8.3 Symbols
according to IEC 60417........................ :
N/A
1.7.8.4
Markings using figures ...................................... : No figures used as marking
N/A
1.7.9
Isolation of multiple power sources .................... : Only one power supply
N/A
1.7.10
IT power distribution systems
Only for Norway
P
1.7.11
Thermostats and other regulating devices
No such devices within the EUT
N/A
1.7.12 Language
........................................................... : English and local language to
each country that would be
marketed
marketed
1.7.13 Durability
P
1.7.14
Removable parts
No such parts
N/A
1.7.15
Replaceable batteries
No battery within the EUT
N/A
Language ............................................................ :
1.7.16
Operator access with a tool ................................ : No such areas
N/A
1.7.17
Equipment for restricted access locations .......... : The EUT is not such types
N/A
Page 8 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
2
PROTECTION FROM HAZARDS
2.1
Protection from electric shock and energy hazards
2.1.1
Protection in operator access areas
P
2.1.1.1
Access to energized parts
See comment below
P
Test by inspection .............................................. : The concerned hazardous parts
are not accessible
P
Test with test finger ............................................ : The concerned hazardous parts
are not accessible
P
Test with test pin ................................................ : Hazardous live parts are not
accessible
P
Test with test probe ............................................ : No TNV circuit within the EUT
N/A
2.1.1.2 Battery
compartments ........................................ : No battery compartment within
the EUT
N/A
2.1.1.3
Access to ELV wiring
No ELV circuit within the EUT
N/A
Working voltage (V); minimum distance (mm)
through insulation
through insulation
2.1.1.4
Access to hazardous voltage circuit wiring
N/A
2.1.1.5 Energy
hazards
.................................................. : (see appended table 2.1.1.5)
P
2.1.1.6
Manual controls
No such devices
N/A
2.1.1.7
Discharge of capacitors in equipment
P
Time-constant (s); measured voltage (V)............ : 1 s, 0 Vpeak (limit: measured
max. voltage 370 Vpeak x 37 %
= 137 Vpeak, 0.33 ms)
= 137 Vpeak, 0.33 ms)
2.1.2
Protection in service access areas
No such areas
N/A
2.1.3
Protection in restricted access locations
No such areas
N/A
2.2 SELV
circuits
2.2.1 General
requirements
P
2.2.2
Voltages under normal conditions (V)................. : Measured max. 24.1 Vdc
(See also the Note on next
page)
page)
P
2.2.3
Voltages under fault conditions (V) ..................... : Measured max. 23.5 Vdc (see
also appended table 5.3)
P
2.2.3.1
Separation by double insulation or reinforced
insulation (method 1)
insulation (method 1)
P
Page 9 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
2.2.3.2
Separation by earthed screen (method 2)
N/A
2.2.3.3
Protection by earthing of the SELV circuit
(method 3)
(method 3)
N/A
2.2.4
Connection of SELV circuits to other circuits....... : SELV circuits only connected to
SELV circuits
P
Note:
Model MU15-C240010-C5:
The voltage measured between T1, pin A-B is 66.8 Vpeak
The voltage measured between T1 after D7 is 24.1 Vdc
2.3 TNV
circuits
2.3.1
Limits
No TNV circuit within the EUT
N/A
Type of TNV circuits............................................ :
2.3.2
Separation from other circuits and from
accessible parts
accessible parts
N/A
Insulation
employed ............................................ :
2.3.3 Separation
from hazardous voltages
N/A
Insulation
employed ............................................ :
2.3.4
Connection of TNV circuits to other circuits
N/A
Insulation
employed ............................................ :
2.3.5
Test for operating voltages generated externally
N/A
2.4
Limited current circuits
2.4.1 General
requirements
P
2.4.2 Limit
values
P
Frequency
(Hz) ................................................... : See the Note on next page
Measured
current (mA) ....................................... : See the Note on next page
Measured
voltage
(V).......................................... : See the Note on next page
Measured capacitance (
µF) ................................: Measured max. 2200 pF
2.4.3
Connection of limited current circuits to other
circuits
circuits
N/A