JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online
Page 46 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
4.5
TABLE: temperature rise measurements
P
test
voltage (V) ....................................
90 254 264
t1 (
°C) ..................................................
40 40 40
t2 (
°C) ..................................................
40 40 40
maximum temperature T of part/at::
T (
°C)
allowed
T
max
(
°C)
Primary lead wire
40
62.2
61.5
105
L1 coil
80
71.2
70.6
120
CX1 / C1
69.6
67.7
66.8
100
D2
81.8 80.1 80.5 130
Q1
83.7 97.3 98.4 130
D7 / CY1
96.4
96.6
96.5
125
T1
coil
87.8 91.4 92.4
110,
B
T1
core
82.6 85.6 85.8
110,
B
U2
74.4 79.5 77.9 100
L2
coil
71.1 73.2 73.0 120
Output
cord
63.3 65.1 65.6 80
C5 / C9
76.1
76.4
76.7
105
Enclosure inside near T1
72.7
75.3
75.5
For stress
relief test
Enclosure outside near T1
59.7
55.5
55.1
95
temperature T of winding:
R
1
(
Ω)
R
2
(
Ω)
T (
°C)
allow
ed
T
max
(
°C)
insulation
class
— —
—
—
—
—
Note:
1. Tested on model: MU15-C033280-C5 (Horizontal)
2. Max. operation ambient is considered as 40
2. Max. operation ambient is considered as 40
°C which declared by the manufacturer.
Page 47 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
4.5
TABLE: temperature rise measurements
P
test
voltage (V) ....................................
90 254 264
t1 (
°C) ..................................................
40 40 40
t2 (
°C) ..................................................
40 40 40
maximum temperature T of part/at::
T (
°C)
allowed
T
max
(
°C)
Primary lead wire
69.9
63.0
62.3
105
L1 coil
103.7
82.0
81.6
120
CX1 / C1
81.4
75.2
74.8
100
D2
94.8 87.8 88.1 130
Q1 96.1
105.6
106.7
130
D7 / CY1
94.9
95.1
95.6
125
T1 coil
94.1
99.0
101.2
110, B
T1
core
84.7 89.4 90.4
110,
B
U2
79.6 83.9 84.5 100
L2
coil
72.1 74.0 73.8 120
Output
cord
58.4 59.3 60.1 80
C5 / C9
79.7
81.3
80.7
105
Enclosure inside near T1
73.1
75.6
75.4
For stress
relief test
Enclosure outside near T1
59.7
58.2
57.7
95
temperature T of winding:
R
1
(
Ω)
R
2
(
Ω)
T (
°C)
allow
ed
T
max
(
°C)
insulation
class
— —
—
—
—
—
Note:
1. Tested on model: MU15-C060250-C5 (Vertical)
2. Max. operation ambient is considered as 40
2. Max. operation ambient is considered as 40
°C which declared by the manufacturer.
Page 48 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
4.5
TABLE: temperature rise measurements
P
test
voltage (V) ....................................
90 254 264
t1 (
°C) ..................................................
40 40 40
t2 (
°C) ..................................................
40 40 40
maximum temperature T of part/at::
T (
°C)
allowed
T
max
(
°C)
Primary lead wire
69.1
62.0
62.4
105
L1 coil
101.6
79.1
79.5
120
CX1 / C1
79.2
72.5
71.7
100
D2
94.5 87.3 88.6 130
Q1 100.1
109.1
110.0
130
D7 / CY1
95.4
97.4
97.2
125
T1 coil
96.2
102.4
102.3
110, B
T1
core
88.2 93.8 94.5
110,
B
U2
83.6 88.7 88.1 100
L2
coil
74.4 77.8 74.0 120
Output
cord
60.7 63.4 61.3 80
C5 / C9
80.2
83.2
81.0
105
Enclosure inside near T1
76.5
79.7
77.8
For stress
relief test
Enclosure outside near T1
66.7
65.2
60.1
95
temperature T of winding:
R
1
(
Ω)
R
2
(
Ω)
T (
°C)
allow
ed
T
max
(
°C)
insulation
class
— —
—
—
—
—
Note:
1. Tested on model: MU15-C060250-C5 (Horizontal)
2. Max. operation ambient is considered as 40
2. Max. operation ambient is considered as 40
°C which declared by the manufacturer.
Page 49 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
4.5
TABLE: temperature rise measurements
P
test
voltage (V) ....................................
90 254 264
t1 (
°C) ..................................................
40 40 40
t2 (
°C) ..................................................
40 40 40
maximum temperature T of part/at::
T (
°C)
allowed
T
max
(
°C)
Primary lead wire
47.9
49.2
49.5
105
L1
coil
54.9 55.1 54.8 120
CX1 / C1
53.2
53.9
53.7
100
D2
59.2 60.1 60.3 130
Q1
62.8 64.8 65.0 130
D7 / CY1
57.6
59.0
59.1
125
T1
coil
59.9 61.4 61.6
110,
B
T1
core
64.2 68.5 67.8
110,
B
U2
62.7 67.1 67.3 100
L2
coil
60.6 61.8 61.5 120
Output
cord
53.2 54.2 53.8 80
C5 / C9
49.7
50.5
50.6
105
Enclosure inside near T1
54.6
55.7
56.0
For stress
relief test
Enclosure outside near T1
54.3
55.6
53.8
95
temperature T of winding:
R
1
(
Ω)
R
2
(
Ω)
T (
°C)
allow
ed
T
max
(
°C)
insulation
class
— —
—
—
—
—
Note:
1. Tested on model: MU15-C240010-C5 (Vertical)
2. Max. operation ambient is considered as 40
2. Max. operation ambient is considered as 40
°C which declared by the manufacturer.