Document
EMC - CB Certificate
Brand
Device
Audio
File
on-call-sm2.pdf
Date

JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online

 
 
 
 
Page 16 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
3)  Tested model: MU15-C060250-C5 
Transformer (T1) 
Vrms  Vpeak Vrms Vpeak Vrms Vpeak Vrms Vpeak
Pri. pins 
Sec. Pins 
1  2 3 4 
196  364 237 436 208 324 208 332 
194  336 242 440 209 324 208 332 
4)  Tested model: MU15-C240010-C5 
Transformer (T1) 
Vrms  Vpeak Vrms Vpeak Vrms Vpeak Vrms Vpeak
Pri. pins 
Sec. Pins 
1  2 3 4 
197  376 211 464 210 328 210 324 
193  332 218 480 209 328 209 328 
 
5)  The max. working voltages measured between CY1 pin 1 and CY1 pin 2:   324  V peak /  209  V rms. 
 
6)  The max. working voltages: 
Measured between U2 primary pin 3 and U2 secondary pin 1:   352 V peak /  211 V rms. 
Measured between U2 primary pin 4 and U2 secondary pin 1:   352 V peak /  209 V rms. 
Measured between U2 primary pin 3 and U2 secondary pin 2:   352 V peak / 209 V rms. 
Measured between U2 primary pin 4 and U2 secondary pin 2:   352 V peak /  209 V rms. 
 
 
 
 
Page 17 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
WIRING, CONNECTIONS AND SUPPLY 
 
 
3.1 General 
 
3.1.1 
Current rating and overcurrent protection 
(see appended table 1.5.1) 
3.1.2 
Protection against mechanical damage 
Smooth wireways 
3.1.3 
Securing of internal wiring 
All internal wirings are suitable 
fixed 
3.1.4 
Insulation of conductors 
 
3.1.5 
Beads and ceramic insulators 
 
N/A 
3.1.6 
Screws for electrical contact pressure 
No screws are used as 
electrical connections 
N/A 
3.1.7 
Insulating materials in electrical connections 
 
N/A 
3.1.8 
Self-tapping and spaced thread screws 
No such screws are used 
N/A 
3.1.9 
Termination of conductors 
The termination of conductors 
are hooked and soldered with 
the plug pins, others are 
soldered to PCB 
 
10 N pull test 
 
3.1.10 
Sleeving on wiring 
No sleeving used as 
supplementary insulation 
N/A 
 
3.2 
Connection to an a.c. mains supply or a d.c. mains supply  
 
3.2.1 
Means of connection .......................................... : Integral plug forming as part of 
the equipment 
3.2.1.1 
Connection to an a.c. mains supply 
A mains plug that is part of 
direct plug-in equipment 
3.2.1.2 
Connection to a d.c. mains supply 
 
N/A 
3.2.2 
Multiple supply connections  
There is only one supply 
connection for the EUT 
N/A 
3.2.3 
Permanently connected equipment 
The EUT is not such types 
N/A 
 
Number of conductors, diameter (mm) of cable 
and conduits ....................................................... :
 
 
3.2.4 Appliance 
inlets 
 
N/A 
 
 
 
 
Page 18 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
3.2.5 
Power supply cords  
 
N/A 
3.2.5.1 
AC power supply cords 
 
N/A 
 Type .................................................................... :  
 
 
Rated current (A), cross-sectional area (mm
2
),  
AWG....................................................................:
 
 
3.2.5.2 
DC power supply cords 
 
N/A 
3.2.6 
Cord anchorages and strain relief 
 
N/A 
 
Mass of equipment (kg), pull (N)  .......................:
 
 
 Longitudinal 
displacement (mm)  ........................:
 
 
3.2.7 
Protection against mechanical damage 
 
N/A 
3.2.8 Cord 
guards 
 
N/A 
 
D (mm); test mass (g)  ........................................:
 
 
 
Radius of curvature of cord (mm) .......................:
 
 
3.2.9 
Supply wiring space 
 
N/A 
 
3.3 
Wiring terminals for connection of external conductors 
 
3.3.1 
Wiring terminals 
No wiring terminal 
N/A 
3.3.2 
Connection of non-detachable power supply 
cords 
 
N/A 
3.3.3 Screw 
terminals 
 
N/A 
3.3.4 
Conductor sizes to be connected 
 
N/A 
 
Rated current (A), cord/cable type, cross-
sectional area (mm
2
) ........................................... :
 
 
3.3.5 
Wiring terminal sizes 
 
N/A 
 
Rated current (A), type and nominal thread 
diameter (mm) .................................................... :
 
 
3.3.6 
Wiring terminals design 
 
N/A 
3.3.7 
Grouping of wiring terminals 
 
N/A 
3.3.8 Stranded 
wire 
 
N/A 
 
 
 
 
 
Page 19 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
3.4 
Disconnection from the mains supply 
 
3.4.1 General 
requirement 
 
3.4.2 
Disconnect devices 
Integral plug forming as part of 
the equipment is considered as 
the disconnect device 
3.4.3 
Permanently connected equipment 
The EUT is not such equipment 
N/A 
3.4.4 
Parts which remain energized 
 
N/A 
3.4.5 
Switches in flexible cords 
 
N/A 
3.4.6 
Single-phase equipment and d.c. equipment 
The integral plug of equipment 
is provided  
3.4.7 Three-phase 
equipment 
 
N/A 
3.4.8 
Switches as disconnect devices 
 
N/A 
3.4.9 
Plugs as disconnect devices 
The EUT is direct plug-in 
equipment 
N/A 
3.4.10 Interconnected 
equipment 
 
N/A 
3.4.11 
Multiple power sources 
Only one supply source 
N/A 
 
3.5 
Interconnection of equipment 
 
3.5.1 General 
requirements 
 
3.5.2 
Types of interconnection circuits.......................... : SELV circuits 
3.5.3 
ELV circuits as interconnection circuits  
No ELV circuits 
N/A 
 
Page of 127