Reference No. : 54121104E                                                                                                                  Page 5/17
 
◀  Anam EMC Test Laboratory  ▶
 
 
5. MAINS TERMINAL DISTURBANCE VOLTAGE IN THE FREQUENCY 
RANGE 0.15MHz TO 30MHz
 
 
   5.1. Operating environment 
Temperature 
: 18℃ 
Relative humidity  : 45 % 
 
5.2. Test set-up and procedure 
 
 
 
The mains terminal disturbance voltage was measured with the EUT in a 
Screened room. The EUT was placed on a non-metallic table by 0.8m above   
the metallic grounded floor and 0.4m from the reference ground panel (RGP) 
wall. The distance to other metallic surfaces was at least 0.8m. 
The EUT was tested with the outer conductor of the antenna input connected 
as well as not connected to the ground terminal of the AMN. 
The level of the test signal was 500mV (1 KHz) at coaxial RF input connector. 
Amplitude measurements were performed with a quasi-peak detector and, 
If required, with an average detector. 
 
5.3. Measurement uncertainty 
 
Mains terminal disturbance voltage, quasi-peak detection:  ±2.0dB 
 
Mains terminal disturbance voltage, average detection      :  ±2.0dB 
 
The measurement uncertainty describes the overall uncertainty of the given 
 
measured value during the operation of the EUT in the above-mentioned way. 
 
 
 
 
 
 
Reference No. : 54121104E                                                                                                                  Page 6/17
 
◀  Anam EMC Test Laboratory  ▶
 
 
5.4. Test instrument 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Test site 
Shielded room 
Measurement 
                      Receiver 
R & S 
ESCI 
100348 
Artificial mains 
                      Network 
R & S 
ESH3-Z5 
844249/020 
EMCO 3825/2 90101718 
Test Compact Disc 
Abex 
TCD-782 
N/A 
R. C. Oscillator 
Kenwood 
AG-203A 
3090241 
iPod Apple 
iPod 
N/A 
Signal Generator 
Anritsu 
MG3632A 
MT79870 
 
* R & S: Rohde & Schwarz 
 
5.5. Test protocol 
 
 
Date: April 19, 2011 
 
 
Ungrounded at the Signal GND Terminal on the Rear Enclosure. 
 
An overview sweep performed with peak detector is included in the test 
report as Annex A 
Mode 
Freq. 
(㎒) 
Quasi-peak (㏈㎶) Average 
(㏈㎶) 
Limit 
Disturbance value 
Limit 
Disturbance value 
Line 1 
Line 2 
Line 1 
Line 2 
AUX .158 65.8 52.9 52.8 55.8 39.5 39.3 
  21.134 60.0 47.9 47.8 50.0 42.1 41.4 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The equipment does comply with the requirements. 
 
For the measurement data, see Annex A (2 Copies). 
 
 
 
 
 
 
 
 
 
Reference No. : 54121104E                                                                                                                  Page 7/17
 
◀  Anam EMC Test Laboratory  ▶
 
 
6. DISTURBANCE POWER 
6.1. Operating environment 
Temperature 
: 18℃ 
Relative humidity  : 45% 
 
      6.2. Test set-up and procedure 
 
The EUT was placed on a non-metallic table of 0.8m height. At the side of the 
 
EUT a non-metallic table of 6m length was placed to provide for movement of 
 
the absorbing clamp. The absorbing clamp was applied successively to all leads 
 
whose length was 25 ㎝  or longer, unscreened or screened. For the read, the 
 
maximum measured value at each frequency which was obtained when the 
 
absorbing clamp is moved along the lead was registered. No metallic object, 
 
including a possible other unit of the EUT or any person, was closer to the lead 
 
or unit than 0.8m. All screened and unscreened cables were measured with an 
absorbing clamp, according to EN55013, 5.6. 
 
   6.3. Measurement uncertainty 
 
Radio interference power:  ±2.0 ㏈ 
 
The Measurement uncertainty describes the overall uncertainty of the given   
measured value during operation of the EUT in the above-mentioned way. 
 
   6.4. Test instrumentation 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Measurement 
receiver 
R & S 
ESCI 
100348 
Test Compact Disc 
Abex 
TCD-782 
N/A 
Absorbing clamp 
R & S 
MDS 21 
860846/006 
iPod Apple 
iPod 
N/A 
R. C. Oscillator 
Kenwood 
AG-203A 
3090241 
 
* R & S: Rohde & Schwarz 
 
 
 
 
 
 
 
 
 
Reference No. : 54121104E                                                                                                                  Page 8/17
 
◀  Anam EMC Test Laboratory  ▶
 
 
6.5. Test protocols 
 
Date: April 29, 2011 
 
The equipment does comply with the requirements. Operating condition: The   
 
EUT continuously operated with audio frequency of 1,000 ㎐ color bar being 
 
supplied from the iPod. An absorbing clamp was placed around all leads.   
At each mode, the maximum value at each testing frequency and each output   
lead was registered and attached as follows. 
Test Lead 
Freq. 
(㎒) 
Limit(㏈㎺) Result(㏈㎺) 
QP AV QP  AV 
AUX 
50.73 
45.8 35.8 32.1  30.8 
USB 
84.56 
47.0 37.0 32.6  30.7 
VIDEO 
186.00 
50.8 40.8 33.7  30.8 
AC 
POWER 
CORD 150.00 
49.5 39.5 28.9  15.5 
*: less than 25 ㏈㎺ 
    
Limit 
according 
to 
EN55013:2001+A2(2006)
 
 
Note:1) The spectrum was checked from 30 to 300 ㎒. 
 
     2) The cable (6.0m length) loss is included in a correction factor. 
 
     3) Detector function of the measuring instrument:  
 
 
QP: Quasi-peak, AV: Average 
 
     4) QP line: Limit (㏈㎺) = Frequency (㎒)  ×0.037 + 43.9 
 
              AV line: Limit (㏈㎺) = Frequency (㎒)  ×0.037 + 33.9 
 
     5) *: Less than 25 ㏈㎺ 
 
For the measurement data, see Annex C (4 Copies)   
 
 
 
 
 
 
 
 
 
 
 
 
 
 