JBL ON BEAT XTREME (serv.man6) EMC - CB Certificate ▷ View online
Reference No. : 54121104E Page 5/17
◀ Anam EMC Test Laboratory ▶
5. MAINS TERMINAL DISTURBANCE VOLTAGE IN THE FREQUENCY
RANGE 0.15MHz TO 30MHz
5.1. Operating environment
Temperature
: 18℃
Relative humidity : 45 %
5.2. Test set-up and procedure
The mains terminal disturbance voltage was measured with the EUT in a
Screened room. The EUT was placed on a non-metallic table by 0.8m above
the metallic grounded floor and 0.4m from the reference ground panel (RGP)
wall. The distance to other metallic surfaces was at least 0.8m.
The EUT was tested with the outer conductor of the antenna input connected
as well as not connected to the ground terminal of the AMN.
The level of the test signal was 500mV (1 KHz) at coaxial RF input connector.
Amplitude measurements were performed with a quasi-peak detector and,
If required, with an average detector.
Screened room. The EUT was placed on a non-metallic table by 0.8m above
the metallic grounded floor and 0.4m from the reference ground panel (RGP)
wall. The distance to other metallic surfaces was at least 0.8m.
The EUT was tested with the outer conductor of the antenna input connected
as well as not connected to the ground terminal of the AMN.
The level of the test signal was 500mV (1 KHz) at coaxial RF input connector.
Amplitude measurements were performed with a quasi-peak detector and,
If required, with an average detector.
5.3. Measurement uncertainty
Mains terminal disturbance voltage, quasi-peak detection: ±2.0dB
Mains terminal disturbance voltage, average detection : ±2.0dB
The measurement uncertainty describes the overall uncertainty of the given
measured value during the operation of the EUT in the above-mentioned way.
Reference No. : 54121104E Page 6/17
◀ Anam EMC Test Laboratory ▶
5.4. Test instrument
Equipment
Manufacturer
Type No.
Serial No.
Test site
Shielded room
-
-
Measurement
Receiver
Receiver
R & S
ESCI
100348
Artificial mains
Network
Network
R & S
ESH3-Z5
844249/020
EMCO 3825/2 90101718
Test Compact Disc
Abex
TCD-782
N/A
R. C. Oscillator
Kenwood
AG-203A
3090241
iPod Apple
iPod
N/A
Signal Generator
Anritsu
MG3632A
MT79870
* R & S: Rohde & Schwarz
5.5. Test protocol
Date: April 19, 2011
Ungrounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A
report as Annex A
Mode
Freq.
(㎒)
Quasi-peak (㏈㎶) Average
(㏈㎶)
Limit
Disturbance value
Limit
Disturbance value
Line 1
Line 2
Line 1
Line 2
AUX .158 65.8 52.9 52.8 55.8 39.5 39.3
21.134 60.0 47.9 47.8 50.0 42.1 41.4
The equipment does comply with the requirements.
For the measurement data, see Annex A (2 Copies).
Reference No. : 54121104E Page 7/17
◀ Anam EMC Test Laboratory ▶
6. DISTURBANCE POWER
6.1. Operating environment
Temperature
: 18℃
Relative humidity : 45%
6.2. Test set-up and procedure
The EUT was placed on a non-metallic table of 0.8m height. At the side of the
EUT a non-metallic table of 6m length was placed to provide for movement of
the absorbing clamp. The absorbing clamp was applied successively to all leads
whose length was 25 ㎝ or longer, unscreened or screened. For the read, the
maximum measured value at each frequency which was obtained when the
absorbing clamp is moved along the lead was registered. No metallic object,
including a possible other unit of the EUT or any person, was closer to the lead
or unit than 0.8m. All screened and unscreened cables were measured with an
absorbing clamp, according to EN55013, 5.6.
absorbing clamp, according to EN55013, 5.6.
6.3. Measurement uncertainty
Radio interference power: ±2.0 ㏈
The Measurement uncertainty describes the overall uncertainty of the given
measured value during operation of the EUT in the above-mentioned way.
measured value during operation of the EUT in the above-mentioned way.
6.4. Test instrumentation
Equipment
Manufacturer
Type No.
Serial No.
Measurement
receiver
receiver
R & S
ESCI
100348
Test Compact Disc
Abex
TCD-782
N/A
Absorbing clamp
R & S
MDS 21
860846/006
iPod Apple
iPod
N/A
R. C. Oscillator
Kenwood
AG-203A
3090241
* R & S: Rohde & Schwarz
Reference No. : 54121104E Page 8/17
◀ Anam EMC Test Laboratory ▶
6.5. Test protocols
Date: April 29, 2011
The equipment does comply with the requirements. Operating condition: The
EUT continuously operated with audio frequency of 1,000 ㎐ color bar being
supplied from the iPod. An absorbing clamp was placed around all leads.
At each mode, the maximum value at each testing frequency and each output
lead was registered and attached as follows.
lead was registered and attached as follows.
Test Lead
Freq.
(㎒)
Limit(㏈㎺) Result(㏈㎺)
QP AV QP AV
AUX
50.73
45.8 35.8 32.1 30.8
USB
84.56
47.0 37.0 32.6 30.7
VIDEO
186.00
50.8 40.8 33.7 30.8
AC
POWER
CORD 150.00
49.5 39.5 28.9 15.5
*: less than 25 ㏈㎺
Limit
according
to
EN55013:2001+A2(2006)
Note:1) The spectrum was checked from 30 to 300 ㎒.
2) The cable (6.0m length) loss is included in a correction factor.
3) Detector function of the measuring instrument:
QP: Quasi-peak, AV: Average
4) QP line: Limit (㏈㎺) = Frequency (㎒) ×0.037 + 43.9
AV line: Limit (㏈㎺) = Frequency (㎒) ×0.037 + 33.9
5) *: Less than 25 ㏈㎺
For the measurement data, see Annex C (4 Copies)