JBL ON BEAT XTREME (serv.man5) EMC - CB Certificate ▷ View online

Reference No.: 54121104F
Page 5/13
5. Immunity to RF voltages(S2a)
5.1 Test criteria and test procedure
Operating environment;
Temperature         
: 17 ℃
Relative Humidity  
: 35 %
The EUT was placed 0.1m above a metallic ground plane of dimensions 2 x1m.
The wanted signal was fed to all input terminals respectively and the 
unwanted signal was fed to mains input, audio output and input terminals 
respectively.
The criterion concerning acceptable sound interference is a wanted to 
unwanted audio signal ratio of ≥40dB at a wanted signal level of 50mW.
The audio output power was measured with a 0.5 - 3kHz band-pass filter.
The audio analyzer was applied without a weighting filter.
The ground connection of the input matching network(Rci), output matching 
network(Rco), and mains filter(MSF) were directly connected to the metal table.
The mains filter(MSF) was connected to ground while the other matching 
networks are only connected to ground when they are being used as injection 
ports.
The measurement are performed with TS9980 Ver.2.9.
5.2 Measurement uncertainty
Immunity to conducted voltage : ± 2dB.
5.3 Test result immunity to conducted voltage.
The equipment does comply with the requirements.
For the measurement data, see annex A.
 Anam EMC Test Laboratory ▶
Reference No.: 54121104F
Page 6/13
6. Immunity to ambient electromagnetic fields (S3)
6.1 Test criteria  and test procedure
Operating environment;
Temperature         
: 17 ℃
Relative Humidity  
: 35 %
The EUT was placed on a non-metallic support by 0.1m above the lower 
conductor in the center of the stripline.
The wanted signal was fed to all input terminals respectively .The unwanted 
signal is fed to a matching network of the stripline.
The ground connection of the mains filter(M) was directly connected to the
jacky.
All unused input/output connections on the EUT were terminated and 
shielded with the proper resistance.
The power supply to the mains of the EUT was attached to the mains filter(M).
Ferrite rings for this test was required on all test cables inside the shielded 
room.
The measurement are performed with TS9980 Version 2.9.
6.2 Measurement uncertainty
Radiated fields  : ± 2dB
6.3 Test result immunity from radiated fields.
The equipment does comply with the requirements.
For the measurement data, see annex B.
 Anam EMC Test Laboratory ▶
Reference No.: 54121104F
Page7/13
7. Test instrumentation
 
Signal Generator(SMG)
R & S
835793/023
Signal Generator(SMG)
R & S
835793/024
Signal Generator(SMX)
R & S
837283/004
TV Patter Generator(SGPF)
R & S
835773/001
Sound Tone(41.25MHz)(SBUF-E2)
R & S
837859/001
TV Test Transmitter(SBUF)
R & S
861456/025
RF Step attenuator(139dB)(DPSP)
R & S
836731/003
Millivolt Meter(URV5)
R & S
837256/001
Harmonic filter(ATS-OW)
R & S
316977/003
Bandpass filter(0.5-3kHz)(BP)
Erika Fiedler
6229
Isolation Transformer(TS-TT.3)
Volrio Star
94/109738
Millivolt Meter(URV-3)
R & S
836364/007
AC Millivolt meter(LMV-189AR)
Leader Electronicx
1427669
RF Power AMP(1347F/325LA)
ENI
Audio Analyzer(UPA)
R & S
836798/010
RC Net Work(8,300ohm/RCo)
Erika Fiedler
Mains Filter(MSF)
Erika Fiedler
Coupling Unit(A,M,L,SR)
Erika Fiedler
Matching Net Work(MN)
Erika Fiedler
Mains Filter(M)
Erika Fiedler
Loudspeaker Filter(BS)
Erika Fiedler
RC Net Work(RCi,RCo)
Erika Fiedler
Signal Generator(MG3632A)
Anritsu Corp.
MT39628
 Anam EMC Test Laboratory ▶
Equipment and Type
Manufacturer
Serial NO.
Page of 13
Display

Click on the first or last page to see other ON BEAT XTREME (serv.man5) service manuals if exist.