JBL DUET II (serv.man6) EMC - CB Certificate ▷ View online
IEC 60950-1 (ed.2)
- Page 5 of 6 -
Photos
www.nemko.com
Report No. 114383
IEC 60950-1 (ed.2)
- Page 6 of 6 -
Photos
www.nemko.com
Report No. 114383
IEC 60950-1 (ed.1)
- Page 1 of 8 -
www.nemko.com
Report No. 114383
ATTACHMENT: AUSTRALIAN / NEW ZEALAND DIFFERENCES
Test results according to CB BULLETIN No. 112A, December 2006
Clause
Requirements – Test
Result – Remark
Verdict
ZZ.1 Introduction
This Annex sets out variations between this Standard and IEC 60950-1:2001. These variations indicate
national variations for purposes of the IECEE CB Scheme and will be published in the IECEE CB Bulletin.
These variations are indicated within the body of the Standard.
national variations for purposes of the IECEE CB Scheme and will be published in the IECEE CB Bulletin.
These variations are indicated within the body of the Standard.
ZZ.2 Variations
The variations are as follows:
1.2
Between the definitions for ‘Person, service’ and
‘Range, rated frequency’ insert the following:
‘Range, rated frequency’ insert the following:
POTENTIAL IGNITION SOURCE
1.2.12.201
Class III equipment, powered
from a LPS
from a LPS
N
1.2.12.15 After the definition 1.2.12.15, add the following:
1.2.12.201
POTENTIAL IGNITION SOURCE:
Possible fault which can start a fire if the open-
circuit voltage measured across an interruption or
faulty contact exceeds a value of 50 V (peak) a.c.
or d.c. and the product of the peak value of this
voltage and the measured r.m.s. current under
normal operating conditions exceeds 15 VA.
circuit voltage measured across an interruption or
faulty contact exceeds a value of 50 V (peak) a.c.
or d.c. and the product of the peak value of this
voltage and the measured r.m.s. current under
normal operating conditions exceeds 15 VA.
Such a faulty contact or interruption in an
electrical connection includes those which may
occur in CONDUCTIVE PATTERNS on PRINTED
BOARDS.
electrical connection includes those which may
occur in CONDUCTIVE PATTERNS on PRINTED
BOARDS.
NOTE 201: An electronic protection circuit may be used
to prevent such a fault from becoming a POTENTIAL
IGNITION SOURCE.
to prevent such a fault from becoming a POTENTIAL
IGNITION SOURCE.
NOTE 202: This definition is from AS/NZS 60065:2003.
Class III equipment.
N
1.5.1
Add the following to the end of first paragraph:
‘or the relevant Australian/New Zealand
Standard’.
Standard’.
All critical components are IEC,
UL or CSA certified.
UL or CSA certified.
P
1.5.2
Add the following to the end of first and third dash
items:
items:
‘or the relevant Australian/New Zealand
Standard’.
Standard’.
All critical components are IEC,
UL or CSA certified.
UL or CSA certified.
P
2.1
Delete the Note
Considered.
—
3.2.3
Delete Note 2
Considered.
—
IEC 60950-1 (ed.1)
- Page 2 of 8 -
www.nemko.com
Report No. 114383
3.2.5.1
Modify Table 3B as follows:
Delete the first four rows and replace with
Delete Note 1.
Class III equipment.
N
4.3.6
Replace paragraph three with:
Equipment with a plug portion, suitable for
insertion into a 10 A 3-pin flat-pin socket-outlet
complying with AS/NZS 3112, shall comply with
the requirements in AS/NZS 3112 for equipment
with integral pins for insertion into socket-outlets.
insertion into a 10 A 3-pin flat-pin socket-outlet
complying with AS/NZS 3112, shall comply with
the requirements in AS/NZS 3112 for equipment
with integral pins for insertion into socket-outlets.
Not a direct plug-in equipment.
N
4.3.13.5
Add the following to the end of first paragraph:
‘or AS/NZS 2211.1’.
No Laser product used.
N
4.7
Add the following paragraph:
For alternative tests refer to Clause 4.7.201.
Refer to below.
P