JBL CREATURE III (serv.man6) EMC - CB Certificate ▷ View online
Page 15 of 17 Report No. : W12-950-062
Appendix No. 1
IEC60950_1B - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
Korea Testing Certification
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause
Requirement + Test
Result - Remark
Verdict
3.2.1.1
In Ireland, apparatus which is fitted with a flexible
cable or cord and is designed to be connected to
a mains socket conforming to I.S. 411 by means
of that flexible cable or cord and plug, shall be
fitted with a 13 A plug in accordance with
Statutory Instrument 525:1997 - National
Standards Authority of Ireland (section 28) (13 A
Plugs and Conversion Adaptors for Domestic
Use) Regulations 1997.
cable or cord and is designed to be connected to
a mains socket conforming to I.S. 411 by means
of that flexible cable or cord and plug, shall be
fitted with a 13 A plug in accordance with
Statutory Instrument 525:1997 - National
Standards Authority of Ireland (section 28) (13 A
Plugs and Conversion Adaptors for Domestic
Use) Regulations 1997.
N/A
3.2.4
In Switzerland, for requirements see 3.2.1.1 of
this annex.
this annex.
N/A
3.2.5.1
In the United Kingdom, a power supply cord with
conductor of 1,25 mm2 is allowed for equipment
with a rated current over 10 A and up to and
including 13 A.
conductor of 1,25 mm2 is allowed for equipment
with a rated current over 10 A and up to and
including 13 A.
N/A
3.3.4
In the United Kingdom, the range of conductor
sizes of flexible cords to be accepted by terminals
for equipment with a RATED CURRENT of over
10 A up to and including 13 A is:
• 1,25 mm
sizes of flexible cords to be accepted by terminals
for equipment with a RATED CURRENT of over
10 A up to and including 13 A is:
• 1,25 mm
2
to 1,5 mm
2
nominal cross-sectional
area.
N/A
4.3.6
In the United Kingdom, the torque test is
performed using a socket outlet complying with
BS 1363 part 1:1995, including Amendment
1:1997 and Amendment 2:2003 and the plug part
of DIRECT PLUG-IN EQUIPMENT shall be
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3,
12.9, 12.11, 12.12, 12.13, 12.16 and 12.17,
except that the test of 12.17 is performed at not
less than 125 °C. Where the metal earth pin is
replaced by an Insulated Shutter Opening Device
(ISOD), the requirements of clauses 22.2 and 23
also apply.
performed using a socket outlet complying with
BS 1363 part 1:1995, including Amendment
1:1997 and Amendment 2:2003 and the plug part
of DIRECT PLUG-IN EQUIPMENT shall be
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3,
12.9, 12.11, 12.12, 12.13, 12.16 and 12.17,
except that the test of 12.17 is performed at not
less than 125 °C. Where the metal earth pin is
replaced by an Insulated Shutter Opening Device
(ISOD), the requirements of clauses 22.2 and 23
also apply.
Considered when assessed to
the national standard.
the national standard.
N/A
4.3.6
In Ireland, DIRECT PLUG-IN EQUIPMENT is
known as plug similar devices. Such devices shall
comply with Statutory Instrument 526:1997 -
National Standards Authority of Ireland (Section
28) (Electrical plugs, plug similar devices and
sockets for domestic use) Regulations, 1997.
known as plug similar devices. Such devices shall
comply with Statutory Instrument 526:1997 -
National Standards Authority of Ireland (Section
28) (Electrical plugs, plug similar devices and
sockets for domestic use) Regulations, 1997.
N/A
Page 16 of 17 Report No. : W12-950-062
Appendix No. 1
IEC60950_1B - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
Korea Testing Certification
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause
Requirement + Test
Result - Remark
Verdict
5.1.7.1
In Finland, Norway and Sweden TOUCH
CURRENT measurement results exceeding 3,5
mA r.m.s. are permitted only for the following
equipment:
• STATIONARY PLUGGABLE EQUIPMENT
TYPE A that
CURRENT measurement results exceeding 3,5
mA r.m.s. are permitted only for the following
equipment:
• STATIONARY PLUGGABLE EQUIPMENT
TYPE A that
is intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential
bonding has been applied, for example, in a
telecommunication centre; and
bonding has been applied, for example, in a
telecommunication centre; and
has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR; and
is provided with instructions for the
installation of that conductor by a SERVICE
PERSON;
• STATIONARY PLUGGABLE EQUIPMENT
TYPE B;
• STATIONARY PERMANENTLY CONNECTED
EQUIPMENT.
PERSON;
• STATIONARY PLUGGABLE EQUIPMENT
TYPE B;
• STATIONARY PERMANENTLY CONNECTED
EQUIPMENT.
N/A
6.1.2.1
(A1:2010)
In Finland, Norway and Sweden, add the
following text between the first and second
paragraph of the compliance clause:
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
-
following text between the first and second
paragraph of the compliance clause:
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
-
two layers of thin sheet material, each of
which shall pass the electric strength test below,
or
-
or
-
one layer having a distance through
insulation of at least 0,4 mm, which shall pass the
electric strength test below.
Alternatively for components, there is no distance
through insulation requirements for the insulation
consisting of an insulating compound completely
filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below
and in addition
-
electric strength test below.
Alternatively for components, there is no distance
through insulation requirements for the insulation
consisting of an insulating compound completely
filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below
and in addition
-
passes the tests and inspection criteria of
2.10.11 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.10 shall be performed using 1,5 kV), and
-
multiplied by 1,6 (the electric strength test of
2.10.10 shall be performed using 1,5 kV), and
-
is subject to ROUTINE TESTING for
electric strength during manufacturing, using a
test voltage of 1,5 kV.
test voltage of 1,5 kV.
N/A
Page 17 of 17 Report No. : W12-950-062
Appendix No. 1
IEC60950_1B - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
Korea Testing Certification
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause
Requirement + Test
Result - Remark
Verdict
It is permitted to bridge this insulation with an
optocoupler complying with 2.10.5.4 b).
It is permitted to bridge this insulation with a
capacitor complying with EN 60384-14:2005,
subclass Y2.
A capacitor classified Y3 according to
EN 60384-14:2005, may bridge this insulation
under the following conditions:
-
optocoupler complying with 2.10.5.4 b).
It is permitted to bridge this insulation with a
capacitor complying with EN 60384-14:2005,
subclass Y2.
A capacitor classified Y3 according to
EN 60384-14:2005, may bridge this insulation
under the following conditions:
-
the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
EN 60384-14, which in addition to the Y3 testing,
is tested with an impulse test of 2,5 kV defined in
EN 60950-1:2006, 6.2.2.1;
-
EN 60384-14, which in addition to the Y3 testing,
is tested with an impulse test of 2,5 kV defined in
EN 60950-1:2006, 6.2.2.1;
-
the additional testing shall be performed on
all the test specimens as described in
EN 60384-14:
-
EN 60384-14:
-
the impulse test of 2,5 kV is to be
performed before the endurance test in
EN 60384-14, in the sequence of tests as
described in EN 60384-14.
EN 60384-14, in the sequence of tests as
described in EN 60384-14.
N/A
6.1.2.2
In Finland, Norway and Sweden, the exclusions
are applicable for PERMANENTLY CONNECTED
EQUIPMENT, PLUGGABLE EQUIPMENT TYPE
B and equipment intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a
telecommunication centre, and which has
provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR and is
provided with instructions for the installation of
that conductor by a SERVICE PERSON.
are applicable for PERMANENTLY CONNECTED
EQUIPMENT, PLUGGABLE EQUIPMENT TYPE
B and equipment intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a
telecommunication centre, and which has
provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR and is
provided with instructions for the installation of
that conductor by a SERVICE PERSON.
N/A
7.2
In Finland, Norway and Sweden, for
requirements see 6.1.2.1 and 6.1.2.2 of this
annex.
The term TELECOMMUNICATION NETWORK in
6.1.2 being replaced by the term CABLE
DISTRIBUTION SYSTEM.
requirements see 6.1.2.1 and 6.1.2.2 of this
annex.
The term TELECOMMUNICATION NETWORK in
6.1.2 being replaced by the term CABLE
DISTRIBUTION SYSTEM.
N/A
7.3
In Norway and Sweden, for requirements see
1.2.13.14 and 1.7.2.1 of this annex.
1.2.13.14 and 1.7.2.1 of this annex.
N/A
7.3
In Norway, for installation conditions see EN
60728-11:2005.
60728-11:2005.
N/A
Page 1 of 63 Report No. : W12-950-062
Appendix No. 2
Test Report National and Group Differences for IEC 60950-1 2
nd
Ed.+ A1 Rev. 05 / 2011-11
Korea Testing Certification
National and Group Differences for IEC 60950-1 2
nd
Ed. +A1:2009 as per CB Bulletin
National Differences covered by this report
Country
CENELEC
Group differ.
(see separate
attachment)
Group differ.
(see separate
attachment)
National
differ.
differ.
Base standard
National standard
Tested
AT Austria
Yes
-
IEC 60950-1 ed2 + A1
EN 60950-1/A1:2010
Yes
AU Australia
-
Yes
IEC 60950-1 ed1
AS/NZS 60950.1:2003
+A1+A2+A3
+A1+A2+A3
Yes
Belarus
-
-
IEC 60950-1 ed2 + A1
-
Yes
BE Belgium
Yes
-
IEC 60950-1 ed2 + A1
EN 60950-1/A1:2010
Yes
Brazil
-
-
IEC 60950-1 ed2 + A1
-
Yes
CA Canada
-
Yes
IEC 60950-1 ed2
CAN/CSA-C22.2 No. 60950-1-
07
07
Yes
CH Switzerland
Yes
-
IEC 60950-1 ed2 + A1
SN EN 60950-1/A1:2010
Yes
CN China
-
Yes
IEC 60950 ed3
GB4943-2001
--
CZ Czech Republic
Yes
-
IEC 60950-1 ed2 + A1
EN 60950-1/A1:2010
Yes
DE Germany
Yes
Yes
IEC 60950-1 ed2 + A1
EN 60950-1/A1:2010
VDE 0805-1:2011-01
Yes
DK Denmark
Yes
Yes
IEC 60950-1 ed2 + A1
DS/EN 60950-1/A1:2010
Yes
ES Spain
Yes
-
IEC 60950-1 ed2 + A1
EN 60950-1/A1:2010
Yes
FI Finland
Yes
Yes
IEC 60950-1 ed2 + A1
EN 60950-1/A1:2010
Yes
FR France
Yes
-
IEC 60950-1 ed2 + A1
EN 60950-1/A1:2010
Yes
GB United Kingdom
Yes
Yes
IEC 60950-1 ed2 + A1
BS EN 60950-1/A1:2010
Yes
GR Greece
Yes
-
IEC 60950-1 ed2 + A1
EN 60950-1/A1:2010
Yes
HU Hungary
Yes
-
IEC 60950-1 ed2 + A1
EN 60950-1/A1:2010
Yes
IE Ireland
Yes
-
IEC 60950-1 ed2 + A1
EN 60950-1/A1:2010
Yes
IL Israel
-
Yes
IEC 60950-1 ed2 + A1
SI 60950-1:2009
-
IN India
-
-
IEC 60950-1 ed1
-
Yes
IT Italy
Yes
-
IEC 60950-1 ed2 + A1
EN 60950-1/A1:2010
Yes
JP Japan
-
Yes
IEC 60950-1 ed1
J60950 (H19)
Yes
KR Korea
-
Yes
IEC 60950-1 ed2 + A1
K 60950-1
Yes
MY Malaysia
-
-
IEC 60950-1 ed2 + A1
-
Yes
NO Norway
Yes
-
IEC 60950-1 ed2 + A1
EN 60950-1/A1:2010
-
NL Netherlands
Yes
-
IEC 60950-1 ed2 + A1
EN 60950-1/A1:2010
Yes
PL Poland
Yes
-
IEC 60950-1 ed2 + A1
EN 60950-1/A1:2010
Yes
Russian Republic
-
-
IEC 60950 ed3
-
Yes
Saudi Arabia
-
-
IEC 60950-1 ed1
-
Yes
SE Sweden
Yes
Yes
IEC 60950-1 ed2 + A1
SS-EN 60950-1
Yes
SG Singapore
-
-
IEC 60950-1 ed2 + A1
-
Yes
SI Slovenia
Yes
-
IEC 60950-1 ed2 + A1
SIST EN 60950/A1:2010
Yes
UA Ukraine
-
Yes
IEC 60950 ed3
DSTU 4113-2001
-
US United States of America
-
Yes
IEC 60950-1 ed2
UL 60950-1
Yes
Click on the first or last page to see other CREATURE III (serv.man6) service manuals if exist.