17.2 Block Diagram of Test Setup
17.3 Test Setup and Test Procedure
The surge is to be applied to the EUT power supply terminals via the capacitive coupling network.
Decoupling networks are required in order to avoid possible adverse effects on equipment not under
test that may be powered by the same lines and to provide sufficient decoupling impedance to the surge
wave so that the specified wave may be developed on the lines under test.
The EUT was arranged and connected according to its functional requirements
The EUT was placed on a 0.8m high wooden table, standing on a ground reference plane 2.6m by 1.8m
in size, supplied by the coupling-decoupling network (Best EMC). arranged and connected to satisfy its
functional requirement and the power code between the EUT and the
coupling/decoupling network was less than 2 meters.
The surge is applied to the EUT power supply terminals .
Decoupling networks are required in order to avoid possible adverse effects on equipment not under
test that may be powered by the same lines and to provide sufficient decoupling impedance to the surge
wave so that the specified wave may be developed on the lines under test.
The EUT was arranged and connected according to its functional requirements
The EUT was placed on a 0.8m high wooden table, standing on a ground reference plane 2.6m by 1.8m
in size, supplied by the coupling-decoupling network (Best EMC). arranged and connected to satisfy its
functional requirement and the power code between the EUT and the
coupling/decoupling network was less than 2 meters.
The surge is applied to the EUT power supply terminals .
17.3.1 Photo for test set-up
none
17.4 Test Protocol
Temperature :
23
°C
Relative Humidity:
34%
Test No.
Test
levelkV
Phase
°
Polarity
Diff. /
Com.
Result Comment
1 1
0
°,90°,
180
°,270°
+/-, L-N
Diff.
Pass
2 2
0
°,90°,
180
°,270°
+/-, L-PE
Com.
NA
3 2
0
°,90°,
180
°,270°
+/-, N-PE
Com.
NA
4 0.5
DC
port
DC
Diff.
NA
Notes: “NA” means not applicable.
17.5 Additions, Deviations and Exclusions from Standards
None
Best EMC
EUT
GRP
Report No. JSH006110138-001
Page 69 of 94
18. Immunity to Conducted Disturbances, Induced by Radio-
frequency Fields
frequency Fields
Test result
PASS
18.1 Severity Level and Performance Criterion
18.1.1 Test level
Frequency range 150kHz – 230MHz
Level
Level
Voltage level (e.m.f.)U0 [dB(uV)] U0 (V)
1 120
1
2
130
3
3 140
10
X Special
Special
Notes: 1. “X” is an open level
2. The gray row is the selected test level.
2. The gray row is the selected test level.
18.1.2 Performance Criterion
Performance criterion A
Report No. JSH006110138-001
Page 70 of 94
18.2 Diagram of Test Setup
power lead :
signal cable :
18.3 Test Setup and Test Procedure
The EUT was placed on an insulating support of 0.1m height above a ground reference Plane,
arranged and connected to satisfy its functional requirement.
arranged and connected to satisfy its functional requirement.
All relevant cables were provided with the appropriate coupling and decoupling
devices at a distance between 0.1m and 0.3m from the projected geometry of the EUT on an
insulating support of 0.03m height above the ground reference plane.
The frequency from 0.15MHz to 230MHz was checked.
18.3.1 Photo for test set-up
none
18.4 Test Protocol
Temperature :
23
°C
Relative Humidity:
34%
Test No.
Frequency
(MHz)
Level
V (e.m.f.)
Amplitude
modulation
Injected
point
Result Comment
1 0.15~80 3 1kHz
80%
L-N Pass
2 0.15~80 3 1kHz
80%
L-N-PE NA
18.5 Additions, Deviations and Exclusions from Standards
None
RF Generator
with amplifier
with amplifier
4dB
CDN
EUT
GRP 10cm high
wooden plane
to support The
to support The
3 cm high
wooden plane
to support EUT
wooden plane
to support EUT
AC
power
power
Report No. JSH006110138-001
Page 71 of 94
19. Voltage Dips, Short Interruptions and Voltage Variations
Immunity Test
Immunity Test
Test result
PASS
19.1 Severity Level and Performance Criterion
19.1.1 Test level
Test level
% UT
Voltage dip and short interruptions
% UT
Duration
(in period)
0
100
40
60
70
30
0.5 *
1
5
5
10
25
50
25
50
X **
Notes:
1.“*” for 0.5 period, the test shall be made in positive and negative polarity, i.e.
starting at 0
° and 180°, respectively
2. “**” means “x” is an open duration. This duration can be given in the product
duration between ½ a period and 3000 periods, but duration less than 50 periods
are most common.
3. if the EUT is tested for voltage dips of 100%, it is generally unnecessary to test for
other levels for the same durations. However, for some cases(safeguard systems or
electro-mechanical devices) it is not true. The product specification or product
committee shall give an indication of the applicability of this note.
4. The gray rows are selected test level.
19.1.2 Performance Criterion
Performance criterion C at the test level 30%, 60%
Performance criterion B at the test level 0%.
Performance criterion B at the test level 0%.