JBL CINEMA SOUND 5 (serv.man2) EMC - CB Certificate ▷ View online

 
 
Report No. JSH006110138-001 
Page 68 of 94  
17.2 Block Diagram of Test Setup 
 
 
 
 
17.3 Test Setup and Test Procedure 
The surge is to be applied to the EUT power supply terminals via the capacitive coupling network. 
Decoupling networks are required in order to avoid possible adverse effects on equipment not under  
test that may be powered by the same lines and to provide sufficient decoupling impedance to the surge 
wave so that the specified wave may be developed on the lines under test. 
The EUT was arranged and connected according to its functional requirements 
The EUT was placed on a 0.8m high wooden table, standing on a ground reference plane 2.6m by 1.8m 
in size, supplied by the coupling-decoupling network (Best EMC). arranged and connected to satisfy its 
functional requirement and the power code between the EUT and the  
coupling/decoupling network was less than 2 meters. 
The surge is applied to the EUT power supply terminals .
 
17.3.1 Photo for test set-up 
          
none 
 
17.4 Test Protocol 
Temperature : 
23
°C  
Relative Humidity: 
34% 
 
Test No. 
Test 
levelkV 
Phase
° 
Polarity 
 
Diff. / 
Com. 
Result Comment 
1 1 
0
°,90°, 
180
°,270° 
+/-, L-N 
Diff. 
Pass 
 
2 2 
0
°,90°, 
180
°,270° 
+/-, L-PE 
Com. 
NA 
 
3 2 
0
°,90°, 
180
°,270° 
+/-, N-PE 
Com. 
NA 
 
4 0.5 
DC 
port 
DC 
Diff. 
NA   
 
Notes: “NA” means not applicable.
 
 
 
17.5 Additions, Deviations and Exclusions from Standards 
 
             None
 
 
Best EMC 
 
     EUT 
GRP 
 
 
Report No. JSH006110138-001 
Page 69 of 94  
18. Immunity to Conducted Disturbances, Induced by Radio-
frequency Fields 
 
Test result 
PASS 
 
18.1 Severity Level and Performance Criterion 
18.1.1 Test level 
 
Frequency range 150kHz – 230MHz 
Level 
Voltage level (e.m.f.)U0 [dB(uV)]                                   U0 (V) 
1 120 
130 
3 140 
10 
X Special 
Special 
Notes: 1. “X” is an open level 
2. The gray row is the selected test level. 
18.1.2 Performance Criterion 
 
 
Performance criterion A
 
 
 
 
 
 
Report No. JSH006110138-001 
Page 70 of 94  
18.2 Diagram of Test Setup 
 
 
  
 
power lead : 
 
signal cable :   
 
 
18.3 Test Setup and Test Procedure 
The EUT  was placed on an insulating support of 0.1m height above a ground reference   Plane, 
arranged and connected to satisfy its functional requirement. 
 
All relevant cables were provided with the appropriate coupling and decoupling  
 
devices at a distance between 0.1m and 0.3m from the projected geometry of the EUT on an 
insulating support of  0.03m height above the ground reference plane. 
 
The frequency from 0.15MHz to 230MHz was checked. 
 
18.3.1 Photo for test set-up 
 none 
18.4 Test Protocol 
 
Temperature : 
23
°C  
Relative Humidity: 
34%
 
 
Test No. 
Frequency 
(MHz) 
Level 
V (e.m.f.) 
Amplitude 
modulation 
Injected 
point 
Result Comment 
1 0.15~80 3  1kHz 
80% 
L-N Pass   
2 0.15~80 3  1kHz 
80% 
L-N-PE NA 
 
 
 
 
18.5 Additions, Deviations and Exclusions from Standards 
 
None 
 
  RF Generator 
with amplifier
4dB 
 
    CDN 
   EUT
GRP  10cm high 
wooden plane 
to support The
3 cm high 
wooden plane 
to support EUT
AC 
power
 
 
Report No. JSH006110138-001 
Page 71 of 94  
19. Voltage Dips, Short Interruptions and Voltage Variations 
Immunity Test 
 
Test result 
PASS 
 
19.1 Severity Level and Performance Criterion 
19.1.1 Test level 
 
Test level 
% UT 
Voltage dip and short interruptions 
% UT 
Duration 
(in period) 
100 
40 
60 
70 
30 
0.5 * 

10 
25 
50 
X ** 
 
Notes:   
1.“*” for 0.5 period, the test shall be made in positive and negative polarity, i.e. 
  starting at 0
° and 180°, respectively 
2. “**” means “x” is an open duration. This duration can be given in the product 
                duration between ½ a period and 3000 periods, but duration less than 50 periods 
are most common. 
        3. if the EUT is tested for voltage dips of 100%, it is generally unnecessary to test for 
                other levels for the same durations. However, for some cases(safeguard systems or 
                electro-mechanical devices) it is not true. The product specification or product 
                committee shall give an indication of the applicability of this note. 
                     4. The gray rows are selected test level. 
 
19.1.2 Performance Criterion
 
 
Performance criterion C at the test level 30%, 60% 
Performance criterion B at the test level 0%. 
 