JBL CINEMA SOUND 3 (serv.man2) EMC - CB Certificate ▷ View online

 
 
Report No. JSH006110139-001 
Page 8 of 94  
2.TEST SPECIFICATIONS 
 
2.1 Standards 
 
EN55013:2001/+A1: 2003:
 
Limits and methods of measurement of radio disturbance characteristics of 
broadcast receivers and associated equipment 
 
EN55020: 2002/+A1:2003:
 
Electromagnetic immunity of broadcast receivers and associated 
equipment. 
 
EN55022 +A1: 2000 +A2: 2003:
 information technology equipment – Radio disturbance 
characteristics Limits and methods of measurement. 
 
EN 55024 +A1: 2000 +A2: 2003: Information Technology Equipment – Immunity Characteristics – 
Limits and methods of measurement. 
 
EN 61000-3-2:2000 /+A2: 2005: 
Limits for harmonic current emissions(equipment input current 
<=16A per phase)  
 
EN61000-3-3:1995/+A1:2001/+A2:2005: 
Limitation of voltage fluctuations and flicker in low-voltage 
supply systems for equipment with rated current <=16A 
 
2.2 Mode of operation during the test / Test peripherals used 
 
The EUT was set to normal operation and all the operation modes were observed. 
 
2.3 Instrument list 
 
Equipment 
Type 
Manu. 
Cal. Date 
Due date 
Test Receiver 
ESCS 30 
R&S 
EC 2107 
2006-2-9 2007-2-8 
Test Receiver 
ESIB 26 
R&S 
EC 3045 
2006-7-1 2007-6-30 
Voltage Probe 
ESH2-Z3 
R&S 
EC 2107-1 
2006-2-9 
2007-2-8 
A.M.N. ESH2-Z5 
R&S 
EC 
3119 
2006-2-9 
2007-2-8 
A.M.N. ESH3-Z5 
R&S 
EC 
2109 
2006-2-9 
2007-2-8 
A.M.N. 
ENV 216 
R&S 
EC 3394 
2006-10-18 
2007-10-17 
I.S.N. 
ENY 22 
R&S 
EC 3218 
2006-2-9 
2007-2-8 
I.S.N. 
ENY 41 
R&S 
EC 3220 
2006-2-9 
2007-2-8 
Current probe 
EZ-17 
R&S 
EC 3221 
2006-2-9 
2007-2-8 
Absorbing clamp 
MDS 21 
R&S 
EC 2108 
2006-2-9 
2007-2-8 
Tri-loop HXYZ 
9170 
Schwarzbeck 
EC 
3384 
2006-7-1 
2007-6-3 
Harmonic-flicker 
system 
5001ix-PACS-
CI EC 
2110 
2006-2-9 
2007-2-8 
Conduct immunity 
system 
UCS 500M6B 
EM TEST 
EC 2958 
2006-2-9 
2007-2-8 
Automatic 
transformer 
MV2616 
EM TEST  
EC 2957 
Not required 
Not required 
Capacity clamp 
HFK 
EM TEST 
EC 2959 
Not required 
Not required 
ESD generator 
ditto 
EM TEST 
EC 2956 
2006-2-10 
2007-2-9 
Surge generator 
TSS 500M4 
EM TEST 
EC 2961 
2006-2-9 
2007-2-8 
Surge generator 
TSS 500M2F 
EM TEST 
EC 2960 
2006-2-9 
2007-2-8 
Surge Coupling 
network 
CNV 504M 
EM TEST 
EC 2958-2 
2006-2-9 
2007-2-8 
Surge Coupling 
network 
CNV 504S1 
EM TEST 
EC 2958-1 
2006-2-9 
2007-2-8 
Signal generator 
SML 01 
R&S 
EC 2338 
2006-2-9 
2007-2-8 
 
 
Report No. JSH006110139-001 
Page 9 of 94  
Power amplifier 
75A250 
AR 
EC 3043-1 
2006-8-22 
2007-8-21 
CDN 
CDN M216 
Schaffner 
EC 2113-2 
2005-3-24 
2007-3-23 
CDN 
CDN M316 
Schaffner 
EC 2113-1 
2005-3-24 
2007-3-23 
CDN 
CDN T2 
EM TEST 
EC 3043-2 2006-2-9  2007-2-8 
CDN 
CDN T4 
EM TEST 
EC 3043-4 2006-2-9  2007-2-8 
EM clamp 
EM 101 
EM TEST 
EC 3043-6 
2006-8-22 
2007-8-21 
Power meter 
PM2002 
AR 
EC3043-7 
2006-2-9 
2007-2-8 
Power sensor 
PH2000 
AR 
EC3043-8 
2006-2-9 
2007-2-8 
Attenuator 
ATT6/75 
EM TEST 
EC 3043-3 
2006-2-9 
2007-2-8 
Attenuator 68-6-44 
Weinschel 
EC 
3043-9 
2006-3-3 
2007-3-2 
DDC 
DC 2600 
AR 
EC 3043-5 
2006-2-13 
2007-2-12 
DDC  DC 
6180A AR EC 
3044-5 
2006-2-13 
2007-2-12 
DDC  DC 
7144A AR EC 
3044-6 
2006-2-13 
2007-2-12 
Calibration 
Impedance 
50 AR 
EC 
3043-12 
2006-2-9 
2007-2-8 
Calibration 
Impedance 
R100 AR 
EC 
3043-10 
2006-2-9 
2007-2-8 
Calibration 
Impedance 
R100 AR 
EC 
3043-11 
2006-2-9 
2007-2-8 
Calibration 
Impedance 
CAL U100A 
Schaffner 
EC 2113-3 
2005-3-24 
2007-3-23 
Calibration 
Impedance 
TRA U150 
Schaffner 
EC 2113-4 
2005-3-24 
2007-3-23 
Ultra-broadband 
antenna 
HL 562 
R&S 
EC 3046-1 
2006-7-1 
2007-6-30 
Horn antenna 
HF 906 
R&S 
EC 3049 
2006-7-1 
2007-6-30 
Pre-amplifier 
Pre-amp 18 
R&S 
EC 3222 
2006-7-1 
2007-6-30 
Log-period antenna 
AT 1080 
AR 
EC 3044-7 
2006-8-22 
2007-8-21 
Horn antenna 
AT 4002 
AR 
EC 3044-8 
2006-8-22 
2007-8-21 
Signal generator 
SMR 20 
R&S 
EC 3044-1 
2006-8-22 
2007-8-21 
Power amplifier 
150W1000 
AR 
EC 3044-2 
2006-8-22 
2007-8-21 
Power amplifier 
25S1G4 
AR 
EC 3044-4 
2006-8-22 
2007-8-21 
Field meter 
FM 5004 
AR 
EC 3044-3 
2006-8-22 
2007-8-21 
Field sensor 
FP 6001 
AR 
EC 3044-9 
2006-8-22 
2007-8-21 
Semi-anechoic 
chamber 
- Albatross 
project 
EC 3048 
2006-6-17 
2007-6-16 
Fully-anechoic 
chamber 
- Albatross 
project 
EC 3047 
2006-6-17 
2007-6-16 
Digital illuminance 
meter 
TES 1332 
TES 
EC 2451 
2006-6-7 
2007-6-6 
Therom-Hygrograph ZJ1-2A 
S.M.I.F. 
EC 
3323  2005-12-28 2006-12-27 
Therom-Hygrograph ZJ1-2A 
S.M.I.F. 
EC 
3324  2006-2-14  2007-2-13 
Therom-Hygrograph ZJ1-2A 
S.M.I.F. 
EC 
3325  2005-12-28 2006-12-27 
Therom-Hygrograph ZJ1-2A 
S.M.I.F. 
EC 
3326  2005-12-28 2006-12-27 
Pressure meter 
YM3 
Shanghai 
Mengde 
EC 3320 
2006-3-7 
2007-3-6 
Isolation transformer 
Intertek 
EC 2100 
Not required 
Not required 
Stable power source 
APS 11020 
APC 
EC 3209 
Not required 
Not required 
Freq. Variable power 
source 
AFC 11010 
APC 
EC 3210 
Not required 
Not required 
Freq. Variable power 
source 
AFC 33020 
APC 
EC 3211 
Not required 
Not required 
Multi-meter 179 FLUKE 
EC 
3326 
2006-9-11 
2007-9-10 
Shielded room 
Zhongyu 
EC 2838 
2004-2-3 
2009-2-2 
Shielded room 
Zhongyu 
EC 2839 
2004-2-3 
2009-2-2 
 
 
 
 
Report No. JSH006110139-001 
Page 10 of 94  
Instrument list for Subcontractor2: SubJiangsu electronic products supervision and inspection institute 
No. Test 
Equipment 
Model 
Serial No. 
Manufacturer 
Last Cal. 
Cal. Due 
Date 
1 EMI 
receiver  ESCS30  1102.4500.30 R/S 2006.02.26 2007.02.25 
2 Artificial 
Mains 
ESH3-Z5 831.5518.52 
R/S 
2006.02.26 
2007.02.25 
3 Bilog 
antenna  CBL6112  117.0800.20 
CHASE 
2006.02.17 
2007.02.16 
4 Absorbing 
clamp 
MDS-21 194.0100.50 
R/S 
2006.02.26 
2007.02.25 
5 Surge 
tester  PSURGE4 083973-09  HAEFELY 2006.04.08 
2007.04.07 
6 Power 
frequency test 
system 
PHF555 081457-04 HAEFELY 
2006.04.08 
2007.04.07 
7 Magnetic 
field 
test system 
MAG100.1 080938-04  HAEFELY 2006.04.08 
2007.04.07 
8 EFT/Burst 
test 
system EFT 
PEFT4010 081203-17  HAEFELY 2006.04.08 
2007.04.07 
9 Static 
discharge tester 
PESD1600 H804247  HAEFELY 2006.04.08 
2007.04.07 
10 Power 
line 
drop-out 
simulator 
PLINE1610 081450-01  HAEFELY 2006.04.08 
2007.04.07 
11 GTEM 
Cell  DN6313 
3.1.1.08 
P.R.China  2006.04.02 
2007.04.01 
12 RF 
amplifier 
75A250 
27314 
Amplifier 
research 
2006.02.17 2007.02.16 
13 RF 
amplifier MODEL5W-
1000 
9957 Amplifier 
research 
2006.02.26 2007.02.25 
14 TS9980 
TS9980 
1014.4074.02  R/S  2006.05.13 
2007.05.12 
15 Semi-anechoic 
chamber 
FACT-3 601 
ETS 
2006.01.10 
2007.01.09 
16 Synthesized 
RF signal 
generator 
QF1481 017 
SMG 
2006.04.15 
2007.04.15 
 
 
Report No. JSH006110139-001 
Page 11 of 94  
 
2.4.Test Summary 
 
This report applies to tested sample only.  This report shall not be reproduced in part without  
written approval of Intertek Testing Service Shanghai Limited. 
 
 
                 TEST ITEM 
RESULT 
NOTE 
Mains terminal continuous disturbance voltage  
Pass 
 
Terminal continuous disturbance voltage at 
antenna terminal 
NA  
Continuous disturbance power 
Pass 
 
Radiated emission 
Pass 
 
Harmonics Pass 
 
Voltage fluctuation-Flicker 
Pass 
 
Electrostatic Discharge (ESD) 
Pass 
 
Electric Fast Transient /Burst (EFT/B) 
Pass 
 
Surge Pass 
 
Injected Current 
Pass 
 
Radiated susceptibility 
Pass 
 
Voltage dips and interruption 
Pass 
 
S1 Pass 
 
S2 Pass 
 
S3 Pass 
 
S4 Pass 
 
  
Notes: 1: NA =Not Applicable 