Page 6 of 99 
 
 
 
Report No.: 17032770 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
General requirements 
 
Safety class of the apparatus  ................................:  Class II 
 
4 
General test conditions 
4.1.4 
Ventilation instructions require the use of the test 
box  
Yes 
 
5 
Marking and instructions 
 
Comprehensible and easily discernible 
Located on rear enclosure. 
 
Permanent durability against water and petroleum 
spirit  
The marking is legible and 
label show not any curling after 
test 
5.1 
a) Identification, maker  ........................................ :  See copy of marking plate on 
page 4. 
 
b) Model number or type reference ....................... :  See copy of marking plate on 
page 4. 
 
c) Class II symbol if applicable  ............................. :  See copy of marking plate on 
page 4. 
 
d) Nature of supply ............................................... :  ~ 
 
e) Rated supply voltage  ....................................... :  100-240V 
 
f) Mains frequency if safety dependant  ................. :  50/60Hz 
 
g) Rated current or power consumption for 
apparatus supplied by supply apparatus for general 
use  ..................................................................... : 
 
N/A 
 
Measured current or power consumption  ............. :   
N/A 
 
Deviation % (max 10%)  ....................................... :   
N/A 
 
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply  : 
See copy of marking plate on 
page 4. 
 
Measured current or power consumption  ............. :  (see appended table 7.1) 
 
Measured current or power consumption for 
Television set  ...................................................... : 
 
N/A 
 
Deviation % (max 10%)  ....................................... :  (see appended table 7.1) 
5.2 
a) Earth terminal  
Class II apparatus 
N/A 
 
b) Hazardous live terminals  
 
N/A 
 
c) Markings on supply output terminals 
 
N/A 
5.3 
a) Use of triangle with exclamation mark  
Marked on the circuit diagram  
 
b) marking on loudspeaker grille, IEC 60417-5036 
 
N/A 
5.4 
Instructions for use 
In English 
 
 
 
 
Page 7 of 99 
 
 
 
Report No.: 17032770 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
5.4.1 
 
a) Mains powered equipment not exposed to 
dripping or splashing. Warning concerning objects 
filled with liquid, etc.  
Stated in the instruction 
 
b) Hazardous live terminals, instructions for wiring   
No such terminals. 
N/A 
 
c) Instructions for replacing lithium battery  
No battery used. 
N/A 
 
d) Class I earth connection warning  
Class II apparatus 
N/A 
 
e) Instructions for multimedia system connection  
 
 
f) Special stability warning for attachment of the 
apparatus to the floor/wall  
No such installation. 
N/A 
 
g) Warning: battery exposure to heat  
No battery used. 
N/A 
 
h) Warning: protective film on CRT face  
No CRT used. 
N/A 
5.4.2 
a-b) Disconnect device: plug/coupler or all-pole 
mains switch location, accessibility and markings  
Stated in the instruction 
regarding the power plug shall 
be readily operable. 
 
c) Instructions for permanently connected equipment   Not permanently connected 
equipment. 
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
 
N/A 
 
Hazardous radiation 
N/A 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h)  
No such device 
N/A 
 
Ionizing radiation under fault condition  
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1:2007
 ............................................................................: 
No laser produced. 
N/A 
 
Emission limits under fault conditions  ....................:   
N/A 
 
7 
Heating under normal operating conditions 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
(see appended table 7.1) 
7.1.1 
Temperature rise of accessible parts  
(see appended table 7.1) 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table 7.1) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier  
(see appended table 7.1) 
7.1.4 
Temperature rise of windings  
(see appended table 7.1) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table 7.1) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
(see appended table 7.2) 
 
 
 
 
 
Page 8 of 99 
 
 
 
Report No.: 17032770 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
Constructional requirements with regard to the protection against electric 
shock 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
No such material 
N/A 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
No voltage setting device, 
replaceable fuse-links or 
drawers. 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the 
removal of a cover which can be removed by hand  
 
8.5 
Class I equipment  
Class II apparatus 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 
N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 
N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
Transformers T1 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)  
Y Capacitors (CY1, CY2 and 
CY4) used between primary 
and secondary circuit. 
8.7 
This clause is void  
 
 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) : 
Thickness of transformer 
bobbin: 0.5mm 
 
Reinforced insulation > 0,4 mm (mm)  .................. : 
See appended table 14 for 
below information: 
thickness of enclosure  
optocoupler 
 
 
 
 
Page 9 of 99 
 
 
 
Report No.: 17032770 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 
N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 
N/A 
 
Reinforced insulation, two layers each of which meet 
10.3  
 
N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3  
3 layers insulation tape 
between primary winding and 
secondary winding, also see 
table 10.3. 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
Double/reinforced insulation 
between primary live parts and 
accessible parts 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts  
Basic insulated secondary 
wires can not touch hazardous 
live parts 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. 
 
 
Double insulation between internal hazardous live 
parts and conductors connected to accessible parts. 
 
8.11 
Detaching of wires  
 
 
No undue reduction of creepages or clearance 
distances if wires become detached  
Primary wires connected to 
power board by connector. 
Wires connected to power 
board by connector and 
amplifier board by soldering 
after inserting into holes of 
PCB with adhesive 
additionally. 
 
Vibration test carried out  ..................................... : 
Yes 
8.12 
This clause is void  
 
 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s)  
 
8.14 
Adequate fastening of covers (push/pull test 50 N for 
10 s)  
No such covers.  
N/A 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
8.16 
Only special supply equipment can be used  
 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
No such wires used. 
N/A 
8.18 
Endurance test as required by 8.17  
 
N/A 
Page of 108