JBL CINEMA 610 EMC - CB Certificate ▷ View online
Page 6 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
3
General requirements
P
Safety class of the apparatus ................................: Class II
P
4
General test conditions
P
4.1.4
Ventilation instructions require the use of the test
box
box
Yes
P
5
Marking and instructions
P
Comprehensible and easily discernible
Located on rear enclosure.
P
Permanent durability against water and petroleum
spirit
spirit
The marking is legible and
label show not any curling after
test
label show not any curling after
test
P
5.1
a) Identification, maker ........................................ : See copy of marking plate on
page 4.
P
b) Model number or type reference ....................... : See copy of marking plate on
page 4.
P
c) Class II symbol if applicable ............................. : See copy of marking plate on
page 4.
P
d) Nature of supply ............................................... : ~
P
e) Rated supply voltage ....................................... : 100-240V
P
f) Mains frequency if safety dependant ................. : 50/60Hz
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ..................................................................... :
apparatus supplied by supply apparatus for general
use ..................................................................... :
N/A
Measured current or power consumption ............. :
N/A
Deviation % (max 10%) ....................................... :
N/A
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply :
us intended for connection to an a.c. mains supply :
See copy of marking plate on
page 4.
page 4.
P
Measured current or power consumption ............. : (see appended table 7.1)
P
Measured current or power consumption for
Television set ...................................................... :
Television set ...................................................... :
N/A
Deviation % (max 10%) ....................................... : (see appended table 7.1)
P
5.2
a) Earth terminal
Class II apparatus
N/A
b) Hazardous live terminals
N/A
c) Markings on supply output terminals
N/A
5.3
a) Use of triangle with exclamation mark
Marked on the circuit diagram
P
b) marking on loudspeaker grille, IEC 60417-5036
N/A
5.4
Instructions for use
In English
P
Page 7 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
dripping or splashing. Warning concerning objects
filled with liquid, etc.
Stated in the instruction
P
b) Hazardous live terminals, instructions for wiring
No such terminals.
N/A
c) Instructions for replacing lithium battery
No battery used.
N/A
d) Class I earth connection warning
Class II apparatus
N/A
e) Instructions for multimedia system connection
P
f) Special stability warning for attachment of the
apparatus to the floor/wall
apparatus to the floor/wall
No such installation.
N/A
g) Warning: battery exposure to heat
No battery used.
N/A
h) Warning: protective film on CRT face
No CRT used.
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
Stated in the instruction
regarding the power plug shall
be readily operable.
regarding the power plug shall
be readily operable.
P
c) Instructions for permanently connected equipment Not permanently connected
equipment.
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
disconnection from the mains
N/A
6
Hazardous radiation
N/A
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No such device
N/A
Ionizing radiation under fault condition
N/A
6.2
Laser radiation, emission limits to IEC 60825-1:2007
............................................................................:
............................................................................:
No laser produced.
N/A
Emission limits under fault conditions ....................:
N/A
7
Heating under normal operating conditions
P
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
fuse links and other protective devices defeated
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table 7.1)
P
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
(see appended table 7.2)
P
Page 8 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
8
Constructional requirements with regard to the protection against electric
shock
shock
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
No such material
N/A
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
No voltage setting device,
replaceable fuse-links or
drawers.
replaceable fuse-links or
drawers.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
P
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
P
8.5
Class I equipment
Class II apparatus
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
P
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
P
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
Transformers T1
P
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
Y Capacitors (CY1, CY2 and
CY4) used between primary
and secondary circuit.
CY4) used between primary
and secondary circuit.
P
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
Thickness of transformer
bobbin: 0.5mm
bobbin: 0.5mm
P
Reinforced insulation > 0,4 mm (mm) .................. :
See appended table 14 for
below information:
below information:
-
thickness of enclosure
-
optocoupler
P
Page 9 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
3 layers insulation tape
between primary winding and
secondary winding, also see
table 10.3.
between primary winding and
secondary winding, also see
table 10.3.
P
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
Double/reinforced insulation
between primary live parts and
accessible parts
between primary live parts and
accessible parts
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
Basic insulated secondary
wires can not touch hazardous
live parts
wires can not touch hazardous
live parts
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
P
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Primary wires connected to
power board by connector.
power board by connector.
Wires connected to power
board by connector and
amplifier board by soldering
after inserting into holes of
PCB with adhesive
additionally.
board by connector and
amplifier board by soldering
after inserting into holes of
PCB with adhesive
additionally.
P
Vibration test carried out ..................................... :
Yes
P
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
P
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
No such covers.
N/A
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
No such wires used.
N/A
8.18
Endurance test as required by 8.17
N/A
Click on the first or last page to see other CINEMA 610 service manuals if exist.