JBL BALBOA SUB10 (serv.man3) EMC - CB Certificate ▷ View online
mikes-testingpartners gmbh
Rev. No 1.0
Page 3
Radiated, radio-frequency, electromagnetic field
Description of the test location
Test location:
Anechoic Chamber A2
Test specification:
Frequency range:
900 MHz Pulse modulation
Field strength: 3
V/m
EuT - antenna distance: 3
m
Modulation:
PM / square wave: 217 Hz / duty cycle: 12.5 %
Antenna polarisation: vertical
The requirements are FULFILLED.
Performance Criterion:
A
Remarks:
mikes-testingpartners gmbh
Rev. No 1.0
Page 4
Electrical fast transients / Burst
Description of the test location
Test location:
Shielded Room S3
Test specification:
Coupling network: 1
kV
Burst frequency: 5.0
kHz
Coupling duration:
≥ 60 sec.
Polarity:
- positive
- negative
Coupling points
Cable description:
AC power line
Screening:
Status:
Signal transmission:
unscreened
active
analogue
active
analogue
Length: 1.0
m
Test result
The requirements are FULFILLED.
Performance Criterion:
B
Remarks:
During fast transients the sine wave disappears and then reappears by itself.
Immunity to Conducted Voltages (S2)
Manufa./Impo. : Harman Consumer
Model : TSS-Sub800/230
E.U.T : Subwoofer
Model : TSS-Sub800/230
E.U.T : Subwoofer
Serial-No. : 001
________________________________________________________________________________________
Report No. : F30272
Attachment Page 1 of 6
Measurement Protocol
Mode
Terminal
Channel Monitoring
Check
S/N
Result
LFE
LFE
left
Speaker
Sound
55
> 6 dB o.L.
LINE
LINE
left
Speaker
Sound
53
> 6 dB o.L.
LINE
MAINS
left
Speaker
Sound
56
DATA!
Test Engineer : Rüdiger Gramsch
Date : 05.10.2005
The above mentioned list shows all measurements performend on the EUT for immunity from
Immunity to Conducted Voltages.
If Result -- DATA! -- then more details on next pages.
If Result -- >x dB o.L. -- then all Results more x dB over Limit
Immunity to Conducted Voltages.
If Result -- DATA! -- then more details on next pages.
If Result -- >x dB o.L. -- then all Results more x dB over Limit
Immunity from Radiated Fields (S3)
Manufa./Impo. : Harman Consumer
Model : TSS-Sub800/230
E.U.T : Subwoofer
Model : TSS-Sub800/230
E.U.T : Subwoofer
Serial-No. : 001
________________________________________________________________________________________
Report No. : F30272
Attachment Page 2 of 6
Measurement Protocol
Mode
Channel
Monitoring
Check
S/N
Result
LINE
left
Speaker
Sound
55
DATA!
Test Engineer : Rüdiger Gramsch
Date : 06.10.2005
The above mentioned list shows all measurements performend on the EUT for immunity from
Immunity from Radiated Fields.
If Result -- DATA! -- then more details on next pages.
If Result -- >x dB o.L. -- then all Results more x dB over Limit
Immunity from Radiated Fields.
If Result -- DATA! -- then more details on next pages.
If Result -- >x dB o.L. -- then all Results more x dB over Limit
Click on the first or last page to see other BALBOA SUB10 (serv.man3) service manuals if exist.