EMC - CB Certificate
Brand
Device
Audio
File
balboa-sub-sm11.pdf
Date

JBL BALBOA SUB (serv.man11) EMC - CB Certificate ▷ View online

 
MIKES BABT PRODUCT SERVICE GmbH 
‹ Ohmstrasse 2-4 ‹ D-94342 Strasskirchen ‹ Tel:+9424-9407-0 ‹ Fax:+9424-9407-60 ‹ Rev. No 5.0 
Page 1
 
 
Address: 
MIKES BABT PRODUCT SERVICE GmbH 
Ohmstrasse 2-4 
94342 Strasskirchen / 
Germany 
 
 Tel. 
+49-9424-9407-0 
Telefax +49-9424-9407-60 
E - mail  
 
 
TEST – Results 
Order No.: 
 F21345-09-00HM
 
 
Applicant Harman 
Consumer 
Group 
Manufacturer 
Meiloon Acoustic Equipments Co., Ltd. 
Type / Model Name  Balboa Sub/230 
Product Description  Powered Subwoofer 
Date received
 
22.11.2004 
Date returned 
-- 
Serial - No.:  PP001 
Retest 
 
Tests are made according to 
EN 55013:2001 
EN 61000-3-2:2000, EN 61000-3-3:1995+A1:2001 
 
 
Type of test 
Limits Test 
Results 
 
Emission / Immunity 
 
margin [dB]  exceeded by [dB] 
 ok 
n.ok 
meet 
criterion 
 
A 4 
Conducted disturbance 
 
 
 
„ 
‰ 
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 
A 5 
Radiated disturbance (electric field) 
 
 
 
‰ 
‰ 
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 
A 6 
Conducted emission at the antenna input 
 
 
 
‰ 
‰ 
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 
A 7 
Disturbance power 
 
 
 
 
„ 
‰ 
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 
A 9 
Radiated disturbance (ERP) 
 
 
 
‰ 
‰ 
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 
H&F  Harmonic current / Voltage fluctuations and flicker 
 
„ 
‰ 
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 
 
S 1 
Immunity requirements - S1 
 
 
‰ 
‰ 
 
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 
S 2 
Immunity requirements - S2 
 
 
‰ 
‰ 
 
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 
S 2c  Immunity requirements - S2c 
 
 
‰ 
‰ 
 
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 
S 3 
Immunity requirements - S3 
 
 
‰ 
‰ 
 
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 
S 4 
Immunity requirements - S4 
 
 
‰ 
‰ 
 
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 
 
I 2 
Electrostatic discharge 
 
 
‰ 
‰ 
 
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 
I 3 
Radiated, radio-frequency, electromagnetic field 
 
‰ 
‰ 
 
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 
I 4 
Electrical fast transients / Burst 
 
 
‰ 
‰ 
 
 
 
Remarks 
Balboa Sub/230 based on SUB 100, test report No.: F21345. 
 
 
 
   
This test result consists of 6 page(s). The test result only corresponds to the tested sample. It is not permitted to copy extracts of 
these test results without the written permission of the test laboratory. 
 
Date 
Tested by 
Checked by 
Test - Result 
„  passed 
01.12.2004
 
 
 
‰  not passed 
Michael Hackl
Ich bin der Verfasser 
dieses Dokuments
2004.12.01 14:14:35 
+01'00'
Eduard Stangl
Ich bestätige die Richtigkeit 
und Integrität dieses 
Dokuments
2004.12.01 16:06:57 +01'00'
 
MIKES BABT PRODUCT SERVICE GmbH 
‹ Ohmstrasse 2-4 ‹ D-94342 Strasskirchen ‹ Tel:+9424-9407-0 ‹ Fax:+9424-9407-60 ‹ Rev. No 5.0 
Page 2
 
 
Conducted disturbance 
 
 
Test point: 
L1 
Operation mode: 
60 Hz 1/8 power 
Remarks: n/a 
Date: 24.11.2004 
Tested by: 
Michael Hackl 
Result: passed 
 
Freq
QP- L
D -Limit 
Freq
AV-L
D -Limit 
Freq
QP- L
D -Limit 
Freq
AV-L
D -Limit 
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
165
31,6
33,6 no Result
220
24,5
38,3
dB [µV]
PK: 
AV:
QP:
 
AV: 
×
 0.15
1
10
20
30  [MHz]
 Detector:
Legend 
QP  LIMIT
AV   LIMIT
0
10
20
30
40
50
60
70
80
 
 
MIKES BABT PRODUCT SERVICE GmbH 
‹ Ohmstrasse 2-4 ‹ D-94342 Strasskirchen ‹ Tel:+9424-9407-0 ‹ Fax:+9424-9407-60 ‹ Rev. No 5.0 
Page 3
 
 
Conducted disturbance 
 
 
Test point: 
Operation mode: 
60 Hz 1/8 power 
Remarks: n/a 
Date: 24.11.2004 
Tested by: 
Michael Hackl 
Result: passed 
 
Freq
QP- L
D -Limit 
Freq
AV-L
D -Limit 
Freq
QP- L
D -Limit 
Freq
AV-L
D -Limit 
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
165
31,6
33,6 no Result
220
24,5
38,3
dB [µV]
PK: 
AV:
QP:
 
AV: 
×
 0.15
1
10
20
30  [MHz]
 Detector:
Legend 
QP  LIMIT
AV   LIMIT
0
10
20
30
40
50
60
70
80
 
 
MIKES BABT PRODUCT SERVICE GmbH 
‹ Ohmstrasse 2-4 ‹ D-94342 Strasskirchen ‹ Tel:+9424-9407-0 ‹ Fax:+9424-9407-60 ‹ Rev. No 5.0 
Page 4
 
 
Disturbance power 
 
 
Test point: 
mains, high level in/out, LFE and line in 
Operation mode: 
60 Hz 1/8 power 
Remarks: n/a 
Date: 24.11.2004 
Tested by: 
Michael Hackl 
Result: passed 
 
30-300
<25
<25
Frequency
[MHz]
Reading 
QP
[dBpW]
Correct.
[dB]
Limit AV
[dBpW]
Reading 
AV
[dBpW]
Limit QP
[dBpW]
Dlimit AV
[dB]
Power
QP
[dBpW]
Dlimit QP
[dB]
Power
AV
[dBpW]
 
 
0
10
20
30
40
50
60
70
80
0
50
100
150
200
250
300
f [MHz]
dBpW
Limit QP (Frequency range: 30 - 300 MHz)
Limit AV (Frequency range: 30 - 300 MHz)
Power QP  dBpW
Power AV  dBpW
QP
AV
<25dB(pW)
 
Page of 7
Display

JBL BALBOA SUB (serv.man11) EMC - CB Certificate ▷ Download

  • DOWNLOAD JBL BALBOA SUB (serv.man11) Service Manual ↓ Size: 410.28 KB | Pages: 7 in PDF or view online for FREE
  • Here you can View online or download the EMC - CB Certificate for the JBL BALBOA SUB (serv.man11) in PDF for free, which will help you to disassemble, recover, fix and repair JBL BALBOA SUB (serv.man11) Audio. Information contained in JBL BALBOA SUB (serv.man11) EMC - CB Certificate (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.