Report Reference No.: CPSA0106916
Clause
Requirement – Test
Result - Remark
Verdict
Test Report EN 60065E Rev. 00 / 2004-09
ZB
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
⎯
2.6.1
DK: certain types of Class I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
N
13.3.1
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
N
15.1.1
DK: mains cord for single-phase equipment having
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
N
DK: Class I equipment with socket-outlets with
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
N
DK: socket-outlets for providing power to Class II
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
N
DK: mains socket-outlets with earthing contact
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
N
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
P
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
N
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
following amendments:
⎯
- dimensions 2,5 A, 250 V socket-outlets shall
comply with Standard Sheet 1 page 132 of
EN 60 065:98
comply with Standard Sheet 1 page 132 of
EN 60 065:98
N
- mechanical strength 2,5 A, 250 V socket-outlets
tested as specified in EN 60 065, 12.1.3
tested as specified in EN 60 065, 12.1.3
N
- protecting rim also tested
N
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
N
Page 20 of 24
Report Reference No.: CPSA0106916
Clause
Requirement – Test
Result - Remark
Verdict
Test Report EN 60065E Rev. 00 / 2004-09
J.2
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
N
ZC
ANNEX ZC TO EN 60 065, A-DEVIATIONS
⎯
5
DE: additional markings required in German language:
⎯
- cathode ray tubes with an accelerating voltage
between 20 kV and 30 kV (marking on the tube)
between 20 kV and 30 kV (marking on the tube)
No CRT
N
- TV receivers whose picture tube has an
accelerating voltage between 20 kV and 30 kV
accelerating voltage between 20 kV and 30 kV
N
- TV receivers whose picture tube has an
accelerating voltage greater than 30 kV
accelerating voltage greater than 30 kV
N
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
accelerating voltage less than 20 kV
N
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
No TV receiver
N
IT: user instructions in Italian language including a
conformity declaration
conformity declaration
N
IT: certification number on the back cover
N
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
N
Page 21 of 24
Report Reference No.: CPSA0106916
Clause
Requirement – Test
Result - Remark
Verdict
Test Report EN 60065E Rev. 00 / 2004-09
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by(W)
3,8 W
—
Position of the functional switch .............................. :
On front
—
- Continuous operation.
Un (V)
In (A)
Pn (W)
Pout (W)
Operation mode
207 V / 50 Hz
0,06
10,0
—
230 V / 50 Hz
0,06
11,4
—
253 V / 50 Hz
0,07
13,0
—
Stand-by mode
207 V / 50 Hz
0,02
2,5
—
230 V / 50 Hz
0,03
3,0
—
253 V / 50 Hz
0,05
3,8
—
Loudspeaker impedance (Ω) .................................. :
—
Several loudspeaker systems
Marking of loudspeaker terminals
Monitored point:
Measured dT(K)
207 V/50 Hz
Measured dT(K)
253 V/50 Hz
Limit dT (K)
Main transformer (T901) core
19,9
25,2
75
Primary connector (CN91)
10,8
12,5
-
Secondary wire (BN92)
14,0
16,7
50
PCB near T901
13,9
16,9
85
PCB near D901
39,0
43,7
85
PCB near IC92
25,3
38,2
85
Bushing body
6,4
6,6
45
Standby switch knob
4,4
4,8
40
Top enclosure above T901
5,1
5,6
30
ANTENNA DAB
8,7
8,4
20
Room ambient
23,8 °C 25,4
°
C
-
Winding temperature rise measurements
P
Ambient temperature t1 (
o
C) .................................. : 25,5
—
Ambient temperature t2 (
o
C) .................................. : 1) 23,8 / 2) 25,4
—
Temperature rise dT of winding:
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit dT (K) Insulation
class
Page 22 of 24
Report Reference No.: CPSA0106916
Clause
Requirement – Test
Result - Remark
Verdict
Test Report EN 60065E Rev. 00 / 2004-09
1) T901 (207 V, 50 Hz)
107,74
116,12
18,5
75
-
2) T901 (253 V, 50 Hz)
107,74
119,30
26,1
75
-
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
> 100
2
Between parts separated by basic or supplementary insulation
-
-
Between parts separated by double or reinforced insulation
> 100
4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120 Vpeak
No
Between parts separated by basic or supplementary insulation
-
-
Between parts separated by double or reinforced insulation
4240 Vpeak
No
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage .............. : 253 V
—
Ambient temperature (
o
C) ...................................... : 24,4 °C–26,7 °C
—
No. Component
No.
Fault
Test
voltage
(V)
Test
Time
Fuse
No.
Short
current
(A)
Result
1
D906
S/C
253
199 min
F901
0,04
D907 damaged.
After 150 min immediately unit shutdown.
No hazard.
After 150 min immediately unit shutdown.
No hazard.
2 D903 S/C
253 30
min
F901
0
Transformer Pri. Winding heated up to
106,3 K and thermal fuse opened.
No hazard.
106,3 K and thermal fuse opened.
No hazard.
3 D908 S/C
253
140 min
F901
0,10
Temperature stabilized at T901 winding:
99,3 K, PCB (T901): 50,5 K,
Ambient: 24,4 °C. No hazard.
99,3 K, PCB (T901): 50,5 K,
Ambient: 24,4 °C. No hazard.
4 D909 S/C
253 18
min
F901
0
Transformer Pri. Winding heated up to
110,4 K and thermal fuse opened.
No hazard.
110,4 K and thermal fuse opened.
No hazard.
5 D912 S/C
253 14
min
F901
0
Transformer Pri. Winding heated up to
106,1 K and thermal fuse opened.
No hazard.
106,1 K and thermal fuse opened.
No hazard.
6 D904 S/C
253 23
min
F901
0
Transformer Pri. Winding heated up to
109,9 K and thermal fuse opened.
No hazard.
109,9 K and thermal fuse opened.
No hazard.
7 C930 S/C
253 27
min
F901
0
Transformer Pri. Winding heated up to
124,5 K and thermal fuse opened.
No hazard.
124,5 K and thermal fuse opened.
No hazard.