Harman Kardon NOVA (serv.man3) EMC - CB Certificate ▷ View online

Report No.:  EM201300303-2                Application No.:  ZJ00029905                       Page 49 of 83 
 
 
Project No.: 
ZJ00029905 
Probe: 
Standard: 
(CE)EN55022 class B_QP 
Power Source:  AC 230V/50Hz 
Test item: 
Conduction Test 
Date: 
2013-6-07 
Temp./Hum.(%RH): 21/56%RH 
Time: 
16:58:45 
EUT: 
Wireless speaker with Bluetooth 
 
 
Model: 
HARMAN KARDON NOVA 
Test Result: 
Pass 
Note:  
Mode6:optical(earphone) 
 
 
 
 
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV) 
Factor(dB) 
(dBuV) 
(dBuV) 
(dB) 
 
1 0.3180 
35.68 
0.12  35.80 
59.76 
-23.96 
QP 
2 0.3180 
30.78 
0.12  30.90 
49.76 
-18.86 
AVG 
3 0.4020 
35.28 
0.12  35.40 
57.81 
-22.41 
QP 
4 0.4020 
30.38 
0.12  30.50 
47.81 
-17.31 
AVG 
5 0.6020 
30.38 
0.12  30.50 
56.00 
-25.50 
QP 
6 0.6020 
22.38 
0.12  22.50 
46.00 
-23.50 
AVG 
7 1.0020 
27.37 
0.13  27.50 
56.00 
-28.50 
QP 
8 1.0020 
22.97 
0.13  23.10 
46.00 
-22.90 
AVG 
9 1.4060 
26.64 
0.16  26.80 
56.00 
-29.20 
QP 
10 1.4060 22.64 0.16  22.80 46.00 -23.20 
AVG 
11 9.2540 32.49 0.61  33.10 60.00 -26.90 
QP 
12 9.2540 27.79 0.61  28.40 50.00 -21.60 
AVG 
 
 
Report No.:  EM201300303-2                Application No.:  ZJ00029905                       Page 50 of 83 
 
 
4.3 VOLTAGE FLUCTUATION AND FLICKS MEASUREMENT 
4.3.1 LIMITS 
Test standard: EN 61000-3-3:2008 
Test Item 
Limit 
Remark 
P
st
 1.0 
P
st 
means short-term flicker indicator. 
P
lt
 0.65 
P
lt
 means long-term flicker indicator. 
T
dt
 (ms) 
500 
T
dt 
means maximum time that dt exceeds 3 %. 
d
max
 (%) 
4% 
d
max
 means maximum relative voltage change. 
dc (%) 
3.3% 
dc means relative steady-state voltage change 
4.3.2 TEST PROCEDURES 
The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated 
to produce the most unfavorable sequence of voltage changes under normal operating 
conditions. 
During the flick measurement, the measure time shall include that part of whole operation 
cycle in which the EUT produce the most unfavorable sequence of voltage changes. The 
observation period for short-term flicker indicator is 10 minutes and the observation period 
for long-term flicker indicator is 2 hours. 
4.3.3 TEST SETUP 
 
 
Harmonics & 
Flicker 
Analyzer 
Power Source 
 
EUT 
 
Support  
Power 
Cord
 
0.8
Report No.:  EM201300303-2                Application No.:  ZJ00029905                       Page 51 of 83 
 
4.3.4 TEST RESULTS 
Flicker Test Summary per EN/IEC61000-3-3  (Run time) 
 
EUT: NOVA  Tested by: ZHOU 
Test category: All parameters (European limits) 
Test Margin: 100 
Test date: 2013-6-10  Start time: 20:10:49  End time: 20:21:10 
Test duration (min): 10 
Data file name: F-000395.cts_data 
Comment: HARMAN KARDON NOVA 
Customer: Customer 
 
Test Result: Pass 
Status: Test Completed 
 
 
Pst
i
 and limit line 
  European 
Limits 
0.25
0.50
0.75
1.00
  
Pst
20:21:09
 
Plt and limit line  
0.00
0.25
0.50
  
Plt
20:21:09
 
Parameter values recorded during the test: 
Vrms at the end of test (Volt): 
229.75 
Highest dt (%): 
-0.28  Test limit (%): 3.30  Pass 
Time(mS) > dt:   
0.0 
Test limit (mS): 
500.0  Pass 
Highest dc (%): 
0.00  Test limit (%): 3.30  Pass 
Highest dmax (%): 
0.16  Test limit (%): 4.00  Pass 
Highest Pst (10 min. period):         0.064 
Test limit:                1.000 
Pass    
Highest Plt (2 hr. period):               0.028 
Test limit:                0.650 
Pass 
 
Report No.:  EM201300303-2                Application No.:  ZJ00029905                       Page 52 of 83 
 
5. IMMUNITY TEST 
5.1 GENERAL DESCRIPTION 
Product Standard 
ETSI EN 301 489-17 V2.2.1 & EN 301 489-3& EN 301 489-1 V1.9.2
 
Test set-up 
Test specification 
ETSI EN 301 489-17 
V2.1.1& EN 301 
489-3 & EN 301 
489-1 V1.9.2 
 
 
EN 61000-4-2 
Electrostatic Discharge – ESD: 
8kV air discharge, 4kV Contact discharge 
Performance Criterion B 
EN 61000-4-3 
Radio-Frequency Electromagnetic Field 
Susceptibility Test – RS: 
80 ~1000 MHz, 1400~2700 MHz 3V/m, 80% 
AM(1kHz),  
Performance Criterion A 
EN 61000-4-4 
Electrical Fast Transient/Burst - EFT, 
AC power Port: 1kV,  
DC power Port: 0.5kV 
Signal and control line: 0.5kV, 
Performance Criterion B 
EN 61000-4-5 
Surge Immunity Test: 
1.2/50 us Open Circuit Voltage, 
8 /20 us Short Circuit Current, 
AC Power Port: line to earth: ±1kV, line to line: 
±0.5kV 
Performance Criterion B 
EN 61000-4-6 
Conducted Radio Frequency Disturbances Test 
–CS: 
0.15 ~ 80 MHz, 3Vrms, 80% AM, 1kHz, 
Performance Criterion A 
EN 61000-4-11 
Voltage dips: 
30 during 25 periods, 
Meets the requirements of  Performance Criterion 
100% during 0.5 cycles, 
100% during 1 cycles, 
Meets the requirements of Performance Criterion B
Voltage interruption: 
100% during 250 cycles, 
Meets the requirements of Performance Criterion C
 