Harman Kardon HS 350 (serv.man3) EMC - CB Certificate ▷ View online
Page 9 of 60 Report No. JSH007120244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
10.3
Insulation resistance and dielectric strength
(See appended table)
Pass
11 FAULT
CONDITIONS
11.1
No shock hazard under fault condition
Pass
11.2
Heating under fault condition
(See appended table)
Pass
No hazard from softening solder
Pass
11.2.1
Measurement of temperature rises
Pass
11.2.2
Temperature rise of accessible parts
Pass
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(See appended table)
Pass
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
Pass
11.2.5
Temperature rise of windings
(see appended table)
Pass
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
(see appended table)
Pass
12 MECHANICAL
STRENGTH
12.1.1
Bump test where mass >7 kg
4.92kg
N/A
12.1.2 Vibration
test
Not carried out, no connection
which might impair safety can
become loosen
which might impair safety can
become loosen
Pass
12.1.3
Impact hammer test
0.5J Pass
Steel ball test
2J Pass
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
Pass
Page 10 of 60 Report No. JSH007120244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
12.1.5
Thermoplastic enclosures stress relief test
70
o
C, 7h
Pass
12.2
Fixing of knobs, push buttons, keys and levers
Pass
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
Pass
Creepage distances in accordance with 13.4
Pass
13.2
Determination of operating voltage
T701: 230Vrms, 550Vp
T702: 380Vrms, 530Vp
T702: 380Vrms, 530Vp
CY701: 350Vrms, 408Vp
Pass
13.3
Clearances
(see appended table)
Pass
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
Pass
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Such circuits are secondary
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
N/A
13.4
Creepage distances
(see appended table)
Pass
Creepage distances greater than table 11 minima
Pass
13.5 Printed
boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Page 11 of 60 Report No. JSH007120244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
14 COMPONENTS
14.1 Resistors
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
R701, R702
Pass
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors separately approved .............................. : R701, R702 approved by VDE
Pass
14.2
Capacitors and RC units
Pass
Capacitors separately approved
Yes
Pass
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. : Y1: CY701, CY702, CY703,
CY705
Pass
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. : X2: CX701, CX702, CX703
Pass
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
No such component
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
Such capacitors with metal
cased
cased
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
Such capacitors with metal
cased
cased
N/A
Shielded by a barrier to V-0 or metal ..................... : N/A
14.3
Inductors and windings
Pass
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type .............................. :
manufacturer's name and type .............................. :
Power transformer T701, T702
Line filter LF704, LF705
(See appended table14)
Pass
Transformers and inductors separately approved . : No
N/A
14.3.2 General
Pass
14.3.3 Constructional
requirements
Pass
Page 12 of 60 Report No. JSH007120244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
(see appended table)
Pass
14.3.3.2
Transformers meet the constructional
requirements
requirements
Pass
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T701 basic insulation
minimum 4.0 mm between
T701 core and primary,
Supplementary insulation
minimum 4.0mm between
T701 core and secondary.
minimum 4.0 mm between
T701 core and primary,
Supplementary insulation
minimum 4.0mm between
T701 core and secondary.
T702 basic insulation
minimum 4.0 mm between
T702 core and primary,
Supplementary insulation
minimum 4.0mm between
T702 core and secondary.
minimum 4.0 mm between
T702 core and primary,
Supplementary insulation
minimum 4.0mm between
T702 core and secondary.
Pass
Coil formers and partition walls > 0,4 mm
T701 bobbin: 0.75mm min.
T702 bobbin: 0.75mm min.
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II construction
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T701 basic insulation
minimum 4.0 mm between
T701 core and primary,
Supplementary insulation
minimum 4.0mm between
T701 core and secondary.
minimum 4.0 mm between
T701 core and primary,
Supplementary insulation
minimum 4.0mm between
T701 core and secondary.
T702 basic insulation
minimum 4.0 mm between
T702 core and primary,
Supplementary insulation
minimum 4.0mm between
T702 core and secondary.
minimum 4.0 mm between
T702 core and primary,
Supplementary insulation
minimum 4.0mm between
T702 core and secondary.
Pass
Coil formers and partition walls > 0,4 mm
T701 bobbin: 0.75mm min.
T702 bobbin: 0.75mm min.
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II construction
N/A
Click on the first or last page to see other HS 350 (serv.man3) service manuals if exist.