DOWNLOAD Harman Kardon HS 350 (serv.man3) Service Manual ↓ Size: 4.39 MB | Pages: 61 in PDF or view online for FREE

Model
HS 350 (serv.man3)
Pages
61
Size
4.39 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hs-350-sm3.pdf
Date

Harman Kardon HS 350 (serv.man3) EMC - CB Certificate ▷ View online

 
                                                                   Page 9 of 60                        Report No. JSH007120244-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
10.3 
Insulation resistance and dielectric strength 
(See appended table) 
Pass 
 
11 FAULT 
CONDITIONS 
 
11.1 
No shock hazard under fault condition 
         
 
Pass 
11.2 
Heating under fault condition 
(See appended table) 
Pass 
 
No hazard from softening solder 
 
Pass 
11.2.1 
Measurement of temperature rises 
 
Pass 
11.2.2 
Temperature rise of accessible parts 
 
Pass 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
(See appended table) 
Pass 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not 
more than 100 K for an area not greater than 2 cm²
 N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
 N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
         
 
N/A 
 
Class I protective earthing maintained 
 
N/A 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
         
 Pass 
11.2.5 
Temperature rise of windings 
(see appended table) 
Pass 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
(see appended table) 
Pass 
 
 
12 MECHANICAL 
STRENGTH 
 
12.1.1 
Bump test where mass >7 kg 
4.92kg 
N/A 
12.1.2 Vibration 
test 
Not carried out, no connection 
which might impair safety can 
become loosen 
Pass 
12.1.3 
Impact hammer test 
0.5J Pass 
 
Steel ball test 
2J Pass 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
 Pass 
 
                                                                   Page 10 of 60                        Report No. JSH007120244-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
12.1.5 
Thermoplastic enclosures stress relief test 
70
o
C, 7h 
Pass 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
Pass 
12.3 
Remote controls with hazardous live parts 
         
 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
         
 
N/A 
12.5 
Antenna coaxial sockets providing isolation 
         
 
N/A 
12.6 
Telescoping or rod antennas construction 
 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
 
13.1 
Clearances in accordance with 13.3 
 
Pass 
 
Creepage distances in accordance with 13.4 
 
Pass 
13.2 
Determination of operating voltage 
T701: 230Vrms, 550Vp 
T702: 380Vrms, 530Vp 
CY701: 350Vrms, 408Vp 
Pass 
13.3 
Clearances 
(see appended table) 
Pass 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9
 
Pass 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
Such circuits are secondary 
circuit and do not include 
hazardous voltage, no basic, 
supplementary or reinforced 
insulation required. 
N/A 
13.4 
Creepage distances 
(see appended table) 
Pass 
 
Creepage distances greater than table 11 minima 
         
 Pass 
13.5 Printed 
boards 
         
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 
N/A 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 
N/A 
 
                                                                   Page 11 of 60                        Report No. JSH007120244-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12
         
 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
         
 
N/A 
 
14 COMPONENTS 
 
14.1 Resistors 
 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
R701, R702 
Pass 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 
Resistors separately approved  .............................. : R701, R702 approved by VDE
 
Pass 
14.2 
Capacitors and RC units 
 
Pass 
 
Capacitors separately approved 
Yes  
Pass 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  .. : Y1: CY701, CY702, CY703, 
CY705 
Pass 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  .. : X2: CX701, CX702, CX703 
Pass 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ..................... :
No such component 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better ....................................................................... :
Such capacitors with metal 
cased 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better ........................................ :
Such capacitors with metal 
cased 
N/A 
 
Shielded by a barrier to V-0 or metal  ..................... :  N/A 
14.3 
Inductors and windings 
 
Pass 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 N/A 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type .............................. :
Power transformer T701, T702 
Line filter LF704, LF705  
(See appended table14) 
Pass 
 
Transformers and inductors separately approved . : No 
N/A 
14.3.2 General 
 
Pass 
14.3.3 Constructional 
requirements 
 
Pass 
 
                                                                   Page 12 of 60                        Report No. JSH007120244-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
(see appended table) 
Pass 
14.3.3.2 
Transformers meet the constructional 
requirements 
 Pass 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T701 basic insulation 
minimum 4.0 mm between 
T701 core and primary, 
Supplementary insulation 
minimum 4.0mm between 
T701 core and secondary. 
T702 basic insulation 
minimum 4.0 mm between 
T702 core and primary, 
Supplementary insulation 
minimum 4.0mm between 
T702 core and secondary. 
Pass 
 
Coil formers and partition walls > 0,4 mm 
T701 bobbin: 0.75mm min. 
T702 bobbin: 0.75mm min. 
Pass 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Class II construction 
N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 
N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T701 basic insulation 
minimum 4.0 mm between 
T701 core and primary, 
Supplementary insulation 
minimum 4.0mm between 
T701 core and secondary. 
T702 basic insulation 
minimum 4.0 mm between 
T702 core and primary, 
Supplementary insulation 
minimum 4.0mm between 
T702 core and secondary.
 
Pass 
 
Coil formers and partition walls > 0,4 mm 
T701 bobbin: 0.75mm min. 
T702 bobbin: 0.75mm min.
 
Pass 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Class II construction 
N/A 
Page of 61
Display

Click on the first or last page to see other HS 350 (serv.man3) service manuals if exist.