Harman Kardon HS 350 (serv.man3) EMC - CB Certificate ▷ View online
Page 2 of 60 Report No. JSH007120244-002
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Model and/or type reference.............. : HS 350
Manufacturer ...................................... : WANLIDA GROUP CO., LTD.
WANLIDA INDUSTRY ZONE, NANJING, FUJIAN, CHINA. 363601
Rating(s)............................................. : 100-240V~ 50/60Hz, 230W, Class II
Copy of marking plate
On DVD loader:
Summary of Testing and Conclusions:
From the result of our examination and tests in the submitted samples, conclude they comply with the
requirements of the standard EN 60065_2002+A1_2006.
From the result of our examination and tests in the submitted samples, conclude they comply with the
requirements of the standard EN 60065_2002+A1_2006.
Page 3 of 60 Report No. JSH007120244-002
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Test case verdicts
Test case does not apply to the test object..................:
N/A
Test item does meet the requirement...........................:
P(ass)
Test item does not meet the requirement.....................:
F(ail)
Testing
Date of receipt of test item ...........................................:
December 06, 2007
Date(s) of performance of test......................................:
December 06, 2007 – January 09, 2008
General remarks
This report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item(s) tested.
Determination of the test result includes consideration of measurement uncertainty from the test equipment
and methods.
"(see appended table)" refers to a table appended to the report.
“(see remark #)” refers to a remark appended to the report.
“(see Annex #) refers to an annex appended to the report.
Throughout this report a point is used as the decimal separator.
General product information:
N.A.
N.A.
Page 4 of 60 Report No. JSH007120244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................. : Class II Pass
4
GENERAL CONDITIONS OF TESTS
4.1.4 Ventilation
instructions
require the use of the test
box
Yes Pass
5 MARKING
Comprehensible and easily discernible
Printed on the rear enclosure
Pass
Permanent durability against water and petroleum
spirit
spirit
Pass
5.1 Identification,
maker,
model ................................... : harman/kardon Pass
Class II symbol if applicable
Pass
Rated supply voltage and symbol .......................... : 100-240V~ Pass
Frequency if safety dependant
50/60Hz
Pass
Rated current or power consumption .................... : 230W Pass
5.2
Earth terminal
Class II
N/A
Hazardous live terminals
N/A
Supply output terminals (other than mains)
N/A
5.3
Use of triangle with exclamation mark
On PCB
Pass
5.4
Instructions for use
Pass
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled
with liquid, etc.
or splashing. Warning concerning objects filled
with liquid, etc.
Pass
Hazardous live terminals, instructions for wiring
No such terminals
N/A
Instructions for replacing lithium battery
No lithium battery
N/A
Instructions for modem if fitted
No modem fitted
N/A
Class I earth connection warning
N/A
Instructions for multimedia system connection
Pass
Special stability warning for fixed installation
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Pass
Instructions for permanently connected equipment
N/A
Page 5 of 60 Report No. JSH007120244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation
N/A
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
No ionizing radiation
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... : Class 1
Pass
Emission limits under fault conditions .................... : Laser Optical Pickup: Class 1
Pass
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table)
Pass
7.1.1
Temperature rise of accessible parts
(see appended table)
Pass
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
Pass
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table)
Pass
7.1.4
Temperature rise of windings
(see appended table)
Pass
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
Pass
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No such supporting parts
N/A
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
PCB, windings
Pass
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools are required
Pass
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used
Pass
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
Tools are required
Pass
8.5
Class I equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A