Harman Kardon HS 2X0 (serv.man4) EMC - CB Certificate ▷ View online
Test report no. SH09100839-001
Page 40 of 106
TRF55013a/effective date: September 15
th
, 2009
5.5 Measurement Uncertainty
The measurement uncertainty describes the overall uncertainty of the given measured
value during the operation of the EUT.
Measurement uncertainty of mains lead and auxiliary lead:
value during the operation of the EUT.
Measurement uncertainty of mains lead and auxiliary lead:
± 3.69dB
The measurement uncertainty is given with a confidence of 95%, k=2
The measurement uncertainty is traceable to internal procedure TI-036.
The measurement uncertainty is traceable to internal procedure TI-036.
Test report no. SH09100839-001
Page 41 of 106
TRF55013a/effective date: September 15
th
, 2009
6. Radiated emission
Test result: PASS
6.1 Radiated emission limit from frequency range 30MHz – 1000MHz
Equipment type
Source
Frequency (MHz)
Limit value dB(
μV/m)
Quasi-peak
Television receiver,
video recorder and PC
tuner cards
video recorder and PC
tuner cards
Local Oscillator
Other
Other
<=1000
30 to 300
300 to 1000
30 to 230
230 to 1000
30 to 300
300 to 1000
30 to 230
230 to 1000
Fundamental 57*
Harmonic 52
Harmonic 56
40
47
Harmonic 52
Harmonic 56
40
47
Television receiver, and
receivers for broadcast
satellite transmission,
(except outdoor unit)
Infrared remote control
units and infrared
headphone system
receivers for broadcast
satellite transmission,
(except outdoor unit)
Infrared remote control
units and infrared
headphone system
Other
30 to 230
230 to 1000
230 to 1000
40
47
47
Frequency modulation
sound receivers and PC
tuner cards
sound receivers and PC
tuner cards
Local oscillator
Other
Other
<=1000
30 to 300
300 to 1000
.30 to 230
230 to 1000
30 to 300
300 to 1000
.30 to 230
230 to 1000
Fundamental 60
Harmonic 52
Harmonic 56
40
47
Harmonic 52
Harmonic 56
40
47
* in Japan, the limit 57dB
μV/m is relax to 66dBμV/m for operation channel <300MHz and to 70dBμV/m
for operation channel >300MHz.
6.2 Block diagram and test set up
Standard signal
generator
generator
Antenna
mast
mast
Turn Table
Test receiver
EUT
Test report no. SH09100839-001
Page 42 of 106
TRF55013a/effective date: September 15
th
, 2009
6.3 Test Setup and Test Procedure
The measurement was performed in a semi-anechoic chamber.
The distance form EUT to receiving antenna is 3 meter.
Test Instruments used were following CISPR 16-1.
Measurement methods and operation conditions of EUT was according to clause 5.2
and 5.7of EN55013
The frequency range from 30MHz to 1000MHz was checked.
The distance form EUT to receiving antenna is 3 meter.
Test Instruments used were following CISPR 16-1.
Measurement methods and operation conditions of EUT was according to clause 5.2
and 5.7of EN55013
The frequency range from 30MHz to 1000MHz was checked.
Test report no. SH09100839-001
Page 43 of 106
TRF55013a/effective date: September 15
th
, 2009
6.4 Test Protocol
Temperature :
20
°C
Relative humidity:
40%
Horizontal
Vertical
Click on the first or last page to see other HS 2X0 (serv.man4) service manuals if exist.