Harman Kardon HS 2X0 (serv.man4) EMC - CB Certificate ▷ View online
Test report no. SH09100839-001
Page 12 of 106
TRF55013a/effective date: September 15
th
, 2009
Emission Test
3. Disturbance voltage at the mains terminals
Test result:
PASS
3.1 Limits of disturbance voltage at the mains terminals
Frequency range
(MHz)
Limits dB(
μv)
Quasi-peak Average
0.15 ~ 0.5
66 ~ 56 *
59 ~ 46 *
0.5 ~ 5
56
46
5 ~ 30
60
50
Note: 1. * means the limit decreasing linearly with the logarithm of the frequency.
2. If the limits for the average detector are met when using the quasi-peak
detector, then the limits for the measurements with the average detector
are considered to e met.
are considered to e met.
3.2 Test setup
Test report no. SH09100839-001
Page 13 of 106
TRF55013a/effective date: September 15
th
, 2009
3.3 Test Setup and Test Procedure
Measurement was performed in shielded room.
Instruments used were following CISPR 16-1.
Measurement methods and operation conditions of EUT was according to clause 5.2
Instruments used were following CISPR 16-1.
Measurement methods and operation conditions of EUT was according to clause 5.2
and 5.3 of EN55013
Frequency range 150kHz – 30MHz was checked and EMI receiver measurement’s
bandwidth was set to 9 kHz.
3.4 Test Protocol
Temperature :
22
°C
Relative Humidity
:
40%
Test Curve:
DVD MODE:
L line
Test report no. SH09100839-001
Page 14 of 106
TRF55013a/effective date: September 15
th
, 2009
N line
Test report no. SH09100839-001
Page 15 of 106
TRF55013a/effective date: September 15
th
, 2009
FM MODE:
L line ungrounding