Harman Kardon HS 2X0 (serv.man4) EMC - CB Certificate ▷ View online

 
Test report no. SH09100839-001 
 
 
Page 12 of 106 
TRF55013a/effective date: September 15
th
, 2009 
Emission Test 
 
3. Disturbance voltage at the mains terminals 
 
Test   result: 
PASS
 
 
3.1 Limits of disturbance voltage at the mains terminals 
 
Frequency range 
(MHz) 
Limits dB(
μv) 
               Quasi-peak                            Average 
 
0.15 ~ 0.5 
66 ~ 56 * 
59 ~ 46 * 
0.5 ~ 5 
56 
46 
5 ~ 30 
60 
50 
 
Note: 1. * means the limit decreasing linearly with the logarithm of the frequency. 
          2. If the limits for the average detector are met when using the quasi-peak 
detector, then the limits for the measurements with the average detector 
are considered to e met. 
 
 
3.2 Test setup 
 
 
 
 
 
 
 
 
 
Test report no. SH09100839-001 
 
 
Page 13 of 106 
TRF55013a/effective date: September 15
th
, 2009 
 
 
3.3 Test Setup and Test Procedure 
 
Measurement was performed in shielded room. 
Instruments used were following CISPR 16-1. 
Measurement methods and operation conditions of EUT was according to clause 5.2 
and 5.3 of EN55013 
Frequency range 150kHz – 30MHz was checked and EMI receiver measurement’s 
bandwidth was set to 9 kHz. 
 
 
3.4 Test Protocol 
Temperature   :   
22
°C  
Relative Humidity  
 40% 
Test Curve: 
DVD MODE:
 
L line 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Test report no. SH09100839-001 
 
 
Page 14 of 106 
TRF55013a/effective date: September 15
th
, 2009 
 
 
 
 
N line 
 
 
Test report no. SH09100839-001 
 
 
Page 15 of 106 
TRF55013a/effective date: September 15
th
, 2009 
 
 
 
FM MODE: 
L line ungrounding 
Page of 107