Harman Kardon HS 2X0 (serv.man2) EMC - CB Certificate ▷ View online
Page 5 of 69
Report No.: SH10011244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: TTRF_IECEN 60065I
TRF originator Intertek ETL SEMKO shanghai
For a PORTABLE SOUND SYSTEM, a warning
that excessive sound pressure from earphones
and headphones can cause hearing loss.
(EN 60065 A11:2008)
that excessive sound pressure from earphones
and headphones can cause hearing loss.
(EN 60065 A11:2008)
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
The statement was provided
in manual.
in manual.
Pass
Instructions for permanently connected equipment Not permanently connected
equipment.
N/A
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 1µSv/h (0,1mR/h)
(EN60065 A11:2008)
(EN60065 A11:2008)
The EUT does not generate
ionizing radiation
ionizing radiation
N/A
A picture is considered to be intelligible if the
specified conditions are met (EN60065 A11:2008)
specified conditions are met (EN60065 A11:2008)
See above
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... : Class 1
Pass
Emission limits under fault conditions .................... : Laser Optical Pickup: Class 1M
or Class 1
Pass
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table)
Pass
7.1.1
Temperature rise of accessible parts
(see appended table)
Pass
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
Pass
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table)
Pass
7.1.4
Temperature rise of windings
(see appended table)
Pass
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
Pass
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No such supporting parts
N/A
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
No such components.
Pass
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools required.
Pass
Page 6 of 69
Report No.: SH10011244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: TTRF_IECEN 60065I
TRF originator Intertek ETL SEMKO shanghai
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used
Pass
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
The EUT is complied with the
requirements
requirements
Pass
8.5
Class I equipment
Class II
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
Pass
Class II: Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
Pass
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
T502, T503, R558 Pass
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
N/A
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
CY501, CY502, CY503,
CY504
CY504
Pass
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
8.7 Void
(A1)
N/A
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N/A
Reinforced insulation > 0,4 mm (mm) .................... : T502 bobbin: 0.8mm min.
T503 bobbin: 0.8mm min.
Optocoupler U502, U504,
U505, U515: 0.40mm min.
U505, U515: 0.40mm min.
Enclosure (front panel): 1.5mm
min.
min.
Separation sheet on internal
enclosure around power board:
0.41mm min.
enclosure around power board:
0.41mm min.
Pass
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
Inside T502, T503.
Pass
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Page 7 of 69
Report No.: SH10011244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: TTRF_IECEN 60065I
TRF originator Intertek ETL SEMKO shanghai
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Withstand 4240Vp test.
Pass
For test specification of non-separable thin sheet
insulation, see 8.22 (A1)
insulation, see 8.22 (A1)
N/A
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
N/A
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
N/A
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
Live wires are double
insulated, no secondary wire
can come closer to live parts
insulated, no secondary wire
can come closer to live parts
Pass
8.11
Detaching of wires
N/A
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Mating lock connector used for
mains. No risk of detached.
mains. No risk of detached.
N/A
Vibration
test carried out ........................................ : No, see above
N/A
8.12 Void
(A1)
N/A
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
Pass
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
Pass
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
Internal wires secured and
keep enough distance from
sharp or hot parts.
keep enough distance from
sharp or hot parts.
Pass
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
Pass
8.19.1 Disconnect
device
The appliance coupler is used
as the disconnect device
as the disconnect device
Pass
All-pole switch or circuit breaker with >3mm
contact separation
contact separation
Mains plug or appliance
coupler.
coupler.
Pass
8.19.2
Mains switch ON indication
Disconnect device is
appliance coupler
appliance coupler
N/A
8.20
Switch not fitted in the mains cord
No such device
N/A
8.21
Bridging components comply with clause 14
No such device within the EUT
N/A
8.22
Non-separable thin sheet material (A1)
No such device within the EUT
N/A
Page 8 of 69
Report No.: SH10011244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: TTRF_IECEN 60065I
TRF originator Intertek ETL SEMKO shanghai
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltages exceeding
1000Vac or 1500Vdc
1000Vac or 1500Vdc
N/A
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
U1=10.3Vp
U2=0.30Vp
U2=0.30Vp
Pass
Discharge not exceeding 45 μC
Less than 45
μC
Pass
Energy of discharge not exceeding 350 mJ
No voltage exceeding 15kV
N/A
9.1.1.2
Test with test finger and test probe
Pass
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
Pass
9.1.3
Ventilation holes and other holes tested by means
of 4 mm x 100 mm test pin
of 4 mm x 100 mm test pin
No enter.
Pass
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
Test probe did not become
hazardous live parts after test.
hazardous live parts after test.
Pass
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Test probe did not become
hazardous live parts after test.
hazardous live parts after test.
Pass
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No such pre-set control used.
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
Less than the limit.
Discharging resistor
R501=R502=560 kΩ max
Discharging resistor
R501=R502=560 kΩ max
Pass
If C is not greater than 0,1 μF no test needed
N/A
9.1.7
Enclosure sufficiently resistant to external force
Pass
Test probe 11 of IEC 61032 for 10 s (50 N)
No damage of enclosure and
no hazardous live parts are
accessible.
no hazardous live parts are
accessible.
Pass
Test hook of fig. 4 for 10 s (20 N)
No hazardous live parts are
accessible.
accessible.
Pass
30 mm diameter test tool for 5 s (100 or 250 N) .... : 100N
Pass
9.2
No hazard after removing a cover by hand
Tools required.
N/A
10 INSULATION
REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
Pass
10.2 Humidity
treatment 48 h or 120 h ........................... : 48h, 30℃, 95%R.H.
Pass