DOWNLOAD Harman Kardon HS 2X0 (serv.man2) Service Manual ↓ Size: 6.3 MB | Pages: 70 in PDF or view online for FREE

Model
HS 2X0 (serv.man2)
Pages
70
Size
6.3 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hs-2x0-sm2.pdf
Date

Harman Kardon HS 2X0 (serv.man2) EMC - CB Certificate ▷ View online

 
          Page 10 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
12.1.3 
Impact hammer test 
0.5J, no hazards after the test 
Pass 
 
Steel ball test 
2J, no hazards after the test 
Pass 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
 N/A 
12.1.5 
Thermoplastic enclosures strain relief test 
70°C / 7 hours 
Pass 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
Pass 
12.3 
Remote controls with hazardous live parts 
No remote control device with 
hazardous live parts 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
No drawer is provided 
N/A 
12.5 
Antenna coaxial sockets providing isolation 
No antenna coaxial socket is 
provided as isolation 
N/A 
12.6 
Telescoping or rod antennas construction 
No such device 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
 
13.1 
Clearances in accordance with 13.3 
 Pass 
 
Creepage distances in accordance with 13.4 
 
Pass 
13.2 
Determination of operating voltage 
T502: 254Vrms, 536Vp 
T503: 275Vrms, 560Vp 
Pass 
13.3 Clearances 
 
Pass 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9
(see appended table) 
Pass 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
Such circuits are secondary 
circuit and do not include 
hazardous voltage, no basic, 
supplementary or reinforced 
insulation required. 
N/A 
13.4 Creepage 
distances 
 
Pass 
 
Creepage distances greater than table 11 minima  (see appended table) 
Pass  
13.5 Printed 
boards 
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 
N/A 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 N/A 
 
          Page 11 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12
 N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
Optocoupler are approved 
components.                      
Pass 
 
 
 
14 COMPONENTS 
 
14.1 Resistors 
 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
R558 Pass 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 
b) Resistors separately approved  .......................... : R558 approved by VDE
 
Pass 
14.2 
Capacitors and RC units 
 
Pass 
 
Capacitors separately approved 
Yes  
Pass 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  .. : Y1: CY501, CY502, CY503, 
CY504 
Pass 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  .. : X2: CX501, CX502, CX503 
Pass 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ..................... :
No such component 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better ....................................................................... :
Such capacitors with metal 
cased 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better ........................................ :
Such capacitors with metal 
cased 
N/A 
 
Shielded by a barrier to V-0 or metal  ..................... :  N/A 
14.3 
Inductors and windings 
 
Pass 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 N/A 
14.3.1 
Transformers and inductors marked with 
manufacturer’s name and type .............................. :
Power transformer T502, T503 
Line filter LF501, LF502  
(See appended table14) 
Pass 
 
Transformers and inductors separately approved . : No 
N/A 
14.3.2 General 
 
Pass 
 
          Page 12 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
14.3.3 Constructional 
requirements 
 
Pass 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
(see appended table) 
Pass 
14.3.3.2 
Transformers meet the constructional 
requirements 
 Pass 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T502 basic insulation 
minimum 5.5 mm between 
T502 core and primary, 
Supplementary insulation 
minimum 4.5mm between 
T502 core and secondary. 
Reinforce insulation minimum 
9.5mm between T502 primary 
and secondary. 
T503 basic insulation 
minimum 4.0 mm between 
T503 core and primary, 
Supplementary insulation 
minimum 4.0mm between 
T503 core and secondary. 
Reinforce insulation minimum 
8.0mm between T503 primary 
and secondary. 
Pass 
 
Coil formers and partition walls > 0,4 mm 
T502 bobbin: 0.8mm min. 
T503 bobbin: 0.8mm min. 
Pass 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Class II construction 
N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 
N/A 
 
          Page 13 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T502 basic insulation 
minimum 5.5 mm between 
T502 core and primary, 
Supplementary insulation 
minimum 4.5mm between 
T502 core and secondary. 
Reinforce insulation minimum 
9.5mm between T502 primary 
and secondary. 
T503 basic insulation 
minimum 4.0 mm between 
T503 core and primary, 
Supplementary insulation 
minimum 4.0mm between 
T503 core and secondary. 
Reinforce insulation minimum 
8.0mm between T503 primary 
and secondary.
 
Pass 
 
Coil formers and partition walls > 0,4 mm 
T502 bobbin: 0.8mm min. 
T503 bobbin: 0.8mm min
 
Pass 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Class II construction 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N/A 
14.4 
High voltage components 
No such components 
N/A 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 
N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
N/A 
14.5 Protective 
devices 
 
Pass 
 
Protective devices used within their ratings 
 
Pass 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
Fuse F501: 3.8mm 
Pass 
14.5.1.1 
a) Thermal cut-outs separately approved 
No such device within the 
EUT 
N/A 
 
b) Thermal cut-outs tested as part of the 
submission 
 N/A 
Page of 70