Harman Kardon HS 1000 EMC - CB Certificate ▷ View online
Page 36 of 68 Report No. SH09021129-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
(alternative) CHANG
SHU
LIANG YI TAPE
INDUSTRY CO
LTD
Nonwoven
cloth/polyethyle
ne terepthalate
film tape, Cat.
No. LY
130℃
IEC 60065
UL: E246820
and tested
with appliance
and tested
with appliance
Insulation tape of
T701, T702
JINGJIANG
YAHUA
PRESSURE
SENSITIVE
GLUE CO LTD
Polyethylene
terephthalate
film tape, Cat.
No. CT, PZ
130℃
IEC 60065
UL: E165111
and tested
with appliance
and tested
with appliance
(alternative) CHANG
SHU
LIANG YI TAPE
INDUSTRY CO
LTD
Polyester (PET)
film insulating
tape with acrylic
adhesive Cat.
No. LY
130℃
IEC 60065
UL: E246820
and tested
with appliance
and tested
with appliance
Tube of T701,
T702
CHANGYUAN
ELECTRONICS(
SHENZHEN)
CB-TT
300V, 200℃,
VW-1
IEC 60065
UL: E180908
and tested
with appliance
(alternative) GREAT
HOLDING
INDUSTRIAL CO
LTD
TFT
300V, 200℃,
VW-1
IEC 60065
UL: E156256
and tested
with appliance
and tested
with appliance
Plastic shell
SHANG HAI
PRET
COMPOSITES
CO LTD
4330R Thickness
min.
3.0mm, V-0,
60℃
IEC60695-11-10 UL:
E301296
and tested
with appliance
Page 37 of 68 Report No. SH09021129-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
(alternative) SHANGHAI
GENIUS
ADVANCED
MATERIAL CO
LTD
567W Thickness
min.
1.6mm, V-0,
60℃
IEC60695-11-10 UL: E210337
and tested
with appliance
(alternative) KINGFA
SCI
&
TECH CO LTD
FRABS-518 Thickness
min.
1.6mm, V-0,
60℃
IEC60695-11-10 UL: E171666
and tested
with appliance
(alternative)
XIAMEN
BESTPOLYMER
CO LTD
501 Thickness
min.
1.6mm, V-0,
60℃
IEC60695-11-10 UL: E303451
and tested
with appliance
Varistor RZ704
Lien Shun
Technical Co.
Ltd.
10D471K -
IEC 61051-2
VDE:
40005858
and tested
with appliance
40005858
and tested
with appliance
(alternative) Xianhua
Advanced
Sensitive
Components Co.,
Ltd
FNR-10K471 -
IEC 61051-2
VDE:
40008242
and tested
with appliance
40008242
and tested
with appliance
Insulation resistor
R701, R702
KOA
CORPORATION
RCR60
11MΩ 1W
IEC 60065
VDE: 124069
Heat shrinkable
tube
DONG GUAN
HUANG FENG
INSULATION
MATERIAL CO
LTD
HFT-2
600V,125℃,
VW-1
IEC 60695-11-10 UL: E236485
and tested
with appliance
with appliance
(alternative)
DONGGUAN
SALIPT CO LTD
SALIPT S-901
600V,125℃,
VW-1
IEC 60695-11-10 UL: E209436
and tested
with appliance
Page 38 of 68 Report No. SH09021129-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
Laser pickup unit Hitachi Media
Electronics Co.,
Ltd
HOP-1200W
CD mode:
60.0μW,
DVD mode:
76.0μW
Class 1
IEC60825-1 Tested
with
appliance
Laser diode for
CD
SHARP
CORPORATION
GH17805B2AS 790nm
Class 1
IEC60825-1 Tested
with
appliance
Laser diode for
DVD
ROHM CO., LTD RLD65MPT5
655nm
Class 1
IEC60825-1 Tested
with
appliance
PCB
SHENZHEN
TONGXIN
CIRCUIT
ELETRIONICS
CO,.LTD.
TY-11
V-0 IEC60695-11-10
UL94
UL(E201362)
PCB,
alternative
various various
V-0 IEC60695-11-10
UL94
UL
Insulation Sheet
(under the power
board)
BERGQUIST CO Sil-Pad 400
Thickness:
0.41mm min.
FV0, 150℃
IEC 60065
UL: E59150
and tested
with appliance
and tested
with appliance
Connector
MOLEX INC
35977
35979
--
IEC 60065
UL: E29179
and tested
with appliance
and tested
with appliance
Internal wiring
SHENZHEN
ZHENGERYA
CABLE CO LTD
NISPTT-2
300V 105
°C
VW-1, 18AWG
double
insulation
IEC 60065
UL: E242647
and tested
with appliance
and tested
with appliance
Page 39 of 68 Report No. SH09021129-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
National differences for CHINA
(These differences are taken from IEC60065:1998 and adopted to IEC
60065:2001.)
(These differences are taken from IEC60065:1998 and adopted to IEC
60065:2001.)
4.2.1 first sentence replaced by:
The apparatus is connected to a supply voltage
of 0.9 times or 1.1 times of any RATED SUPPLY
VOLTAGE for which the apparatus is designed.
The apparatus is connected to a supply voltage
of 0.9 times or 1.1 times of any RATED SUPPLY
VOLTAGE for which the apparatus is designed.
Pass
5.1f
)
Second paragraph replaced by:
………When single rated voltage is given, it
should be marked 220 V, For a rating range, it
should cover 220 V; when multiple RATED
VOLTAGES are given, one of them must be
220V and also factory default setting should be
220 V.
should be marked 220 V, For a rating range, it
should cover 220 V; when multiple RATED
VOLTAGES are given, one of them must be
220V and also factory default setting should be
220 V.
Pass
5.4 replaced by
:
When information with regard to safety is
required according to this standard, this
information shall be given in an instruction for
installation or use and supplied with the
apparatus. This information shall be given in
simplify Chinese where the apparatus is intended
to be used.
required according to this standard, this
information shall be given in an instruction for
installation or use and supplied with the
apparatus. This information shall be given in
simplify Chinese where the apparatus is intended
to be used.
Pass
15.1.1 first sentence replaced by:
Plugs and appliance couplers for the connection
of the apparatus to the MAINS and socket-outlets
and interconnection couplers for providing MAINS
power to other apparatus shall comply with the
Chinese National standards, Industrial standards
or relevant IEC standards for plugs and socket-
outlets, appliance couplers or interconnection
couplers.
Plugs and appliance couplers for the connection
of the apparatus to the MAINS and socket-outlets
and interconnection couplers for providing MAINS
power to other apparatus shall comply with the
Chinese National standards, Industrial standards
or relevant IEC standards for plugs and socket-
outlets, appliance couplers or interconnection
couplers.
Pass
National differences for KOREA
(These differences are taken from IEC 60065(2001)
(These differences are taken from IEC 60065(2001)
+ Amendment 1 (2005).)
5.101
Other marking ; Wording "
“ or an
information regulated in IEC Publication 417
giving high voltage warning to layman shall
be marked, if an apparatus contains a part more
than 600volts.
giving high voltage warning to layman shall
be marked, if an apparatus contains a part more
than 600volts.
N/A
15.1.1
Plugs for the connection of the apparatus to the
supply mains and socket outlets for providing
mains power to other apparatus shall
comply with the Korean requirements (KSC8300
and 8305).
supply mains and socket outlets for providing
mains power to other apparatus shall
comply with the Korean requirements (KSC8300
and 8305).
Pass
31
Radio frequency interference
The apparatus shall comply with the relevant
CISPR requirements.(EMC = EMI + EMS)
The apparatus shall comply with the relevant
CISPR requirements.(EMC = EMI + EMS)
Pass
Click on the first or last page to see other HS 1000 service manuals if exist.