Page 9 of 49
Report No. 910192
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with a
single capacitor complying with 14.2.1 b)
N/A
Basic insulation bridged by components complying
with 14.3.4.3
N/A
8.7
This sub-clause is void
N/A
8.8
Double Insulation: the Basic or Supplementary
insulation > 0.4 mm (mm) .......................................:
Prim wires
P
Reinforced insulation > 0.4 mm (mm) ....................:
P
Thin sheet insulation used inside the enclosure.
In the transformer
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3 dielectric
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3 dielectric
N/A
Reinforced insulation, two layers each of which meet
10.3 dielectric
N/A
Reinforced insulation, three layers any two which
meet 10.3 dielectric
In transformer
P
8.9
Primary Wiring: Adequate insulation between
internal hazardous live conductors and accessible
parts
P
Secondary Wiring: Adequate insulation between
internal hazardous live parts and conductors
connected to accessible parts
P
8.10
Class II Wiring:
(1) Primary: Double insulation between conductors
connected to the mains and accessible parts.
(2) Secondary: Double insulation between
conductors connected to accessible parts and the
mains
Mains wires are double
insulated, no secondary wire
can come in to contact with
bare live parts.
P
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
No risk of any wire becoming
detached.
N/A
Vibration test carried out .........................................: No, no need. See above.
N/A
Page 10 of 49
Report No. 910192
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
8.12
This sub-clause is void
N/A
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
P
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges (2N force)
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
8.19.1
Disconnect device
Mains plug
P
All-pole switch or circuit breaker with >3mm contact
separation
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
N/A
8.21
Bridging components comply with clause 14
N/A
8.22
Test of non-separable thin sheet material
N/A
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
N/A
9.1.1.1 a) Determination of Hazardous Live parts
P
b) Touch current measured from terminal devices
using the network in annex D .................................:
See table 9
P
c) Discharge not exceeding 45 μC
N/A
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
P
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
No ventilation holes on top.
N/A
9.1.4
Terminal devices - within 25mm tested with
1 mm x 20 mm test pin (10 N); test probe D of IEC
61032
P
Page 11 of 49
Report No. 910192
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
0V<2s
P
If C is not greater than 0.1 μF no test needed
N/A
9.1.7
Enclosure sufficiently resistant to external force
a)
Test probe 11 of IEC 61032 for 10 s (50 N)
P
b)
Test hook of fig. 4 for 10 s (20 N)
P
c)
Conductive enclosure: 30 mm diameter test tool for
5 s (100 or 250 N) ...................................................:
250N
P
9.2
No hazard 2s after removing a cover by hand
N/A
10
INSULATION REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩmin. after
surge test for basic and 4 MΩmin. for reinforced
insulation .................................................................:
N/A
10.2
Humidity treatment 48 h or 120 h ...........................: 48h and 120h
P
10.3
Insulation resistance and dielectric strength
between mains terminals
P
Insulation resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
N/A
Insulation resistance across REINFORCED
insulation (Class II)
P
11
FAULT CONDITIONS
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
No hazard from softening solder
P
No flaming more than 10s
P
Soldered terminations not used as protective
mechanism
N/A
11.2.1
Measurement of temperature rises
P
11.2.2
Temperature rise of accessible parts
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N/A
Page 12 of 49
Report No. 910192
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
P
11.2.5
Temperature rise of windings
P
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5 Table 3 e) "Other Parts"
P
12
MECHANICAL STRENGTH
12.1.1
Bump test where mass >7 kg
P
12.1.2
Vibration test (portable, metal, musical amps)
No connection of part, which
might impair safety, can
become loose.
P
12.1.3
Impact hammer test
P
Steel ball test (for non-ventilated solid areas)
3.5J top, sides, back , front
P
12.1.4
Drop test for portable apparatus where mass ≤7 kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
N/A
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A