DOWNLOAD Harman Kardon HK 3700 (serv.man2) Service Manual ↓ Size: 1.11 MB | Pages: 41 in PDF or view online for FREE

Model
HK 3700 (serv.man2)
Pages
41
Size
1.11 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hk-3700-sm2.pdf
Date

Harman Kardon HK 3700 (serv.man2) EMC - CB Certificate ▷ View online

 
                             
ELECTRONICS CO., LTD. 
645, SUNGKOK-DONG, ANSAN-CITY, KYUNGKI-DO, KOREA, 425-834 
                                              TEL.: +82-31-490-2283 
 
EMI TEST REPORT 
Reference No. 54121311C 
Emission of Electromagnetic Disturbances 
 
Equipment Under Test 
Equipment   
   
                : Stereo Receiver 
Type/Model               
 
 : HK3700/230 
Brand Name          : Harman/Kardon 
Manufacturer                  : Harman International Industries, Incorporated 
Total page of this report: 41(including this page) 
 
SUMMARY 
 
Referring to the performance criteria and the operation mode during the test specified in 
this report the equipment does comply with the requirements according to EN 
55013(2001)&+A1(2003)&+A2(2006) and EN61000-3-2(2006)&+A2(2009) and EN 61000-3-
3(2008). The test results in this report apply only to the sample(s) tested. 
 
Report Issued : November 26, 2013 
 
    EUT Received : November 15, 2013 
 
Tested by:                                                                      Approved by: 
               
                                                 
 
  B. S. Lee/ Researching Engineer   
 
  H. S. Seol / General Manager 
 
“This report should not be reproduced except in full without the written approval of the testing
 laboratory.” 
 
Reference No. : 54121311C                                                                                                                  Page 2/41
 
◀  Anam EMC Test Laboratory  ▶
 
 
CONTENTS   
 
 
 
 
 
 
 
Page 
 
1. Client Information
 
 
 
 
 
 
 
 
2. Equipment under test (EUT)
 
 
 
 
 
 
    2.1. Identification of the EUT 
        2.2. Additional information about the EUT 
 
3. Test specifications
  
 
 
 
 
 
 
    3.1. Standard 
        3.2. Additions, Deviations and Exclusions from standard 
    3.3. Purpose of the test 
        3.4. Mode of operation during the test 
 
4. Test summary
 
 
 
 
 
 
 
 
 
5. Mains terminal disturbance voltage 
 
 
 
 
    5.1. Operating environment 
    5.2. Test set-up and procedure 
    5.3. Measurement uncertainty 
    5.4. Test instrumentation 
    5.5. Test protocol 
 
6. Disturbance Radiation 
 
 
 
 
 
 
    6.1. Operating environment 
    6.2. Test set-up and procedure 
    6.3. Measurement uncertainty 
    6.4. Test instrumentation 
    6.5. Test protocol 
 
7. Antenna Terminal Disturbance Voltage
   
 
 
 
11 
    7.1. Operating environment 
    7.2. Test set-up and procedure 
    7.3. Measurement uncertainty 
    7.4. Test instrumentation 
    7.5. Test protocol 
 
 
 
Reference No. : 54121311C                                                                                                                  Page 3/41
 
◀  Anam EMC Test Laboratory  ▶
 
 
8. Disturbance Power
 
 
 
 
 
 
 
13 
    8.1. Operating environment 
    8.2. Test set-up and procedure 
    8.3. Measurement uncertainty 
    8.4. Test instrumentation 
    8.5. Test protocol 
 
9. Harmonics 
 
 
 
 
 
 
 
 
15 
    9.1. Operating environment 
    9.2. Test set-up and procedure 
    9.3. Test instrumentation 
    9.4. Test result 
 
10. Flicker
   
 
 
 
 
 
 
 
16 
    10.1. Operating environment 
    10.2. Test set-up and procedure 
    10.3. Test instrumentation 
    10.4. Test result 
 
11. Photograph of Product
   
 
 
 
 
 
17 
12. Photograph of the test set-up
 
 
 
 
 
 
20 
   
Annex - Measurement data; 
        Annex A : Mains terminal disturbance voltage (6 Copies)  
 
22 
        Annex B : Antenna terminal disturbance voltage (3 Copies) 
 
28 
Annex C : Disturbance Power (7 Copies)   
 
 
 
31 
Annex D : Harmonics (3 Copies)   
 
 
 
 
38 
Annex E : Voltage fluctuations-flicker (1 Copy)   
 
 
41 
 
 
 
 
 
 
 
 
 
 
Reference No. : 54121311C                                                                                                                  Page 4/41
 
◀  Anam EMC Test Laboratory  ▶
 
 
1. CLIENT INFORMATION 
 
The EUT has been tested by request of: 
* Company 
: Harman International Industries, Incorporated 
 
  8500 Balboa Blvd., Northridge, CA 91329, USA 
* Contact Person 
: Huang Coco   
 
 
 
 
2. EQUIPMENT UNDER TEST (EUT) 
2.1. Identification of the EUT 
*Equipment Stereo 
Receiver 
*Model No. 
HK3700/230   
*Brand Name 
Harman/Kardon 
*Serial No. 
AN0155-0001047 
*Manufacturer 
   
Harman International Industries, Incorporated 
8500 Balboa Blvd., Northridge, CA 91329, USA 
 
*Power Rating 
AC 220-240V~, 50/60Hz, 200W 
*Tuner Section 
FM 87.5 ㎒ ~ 108 ㎒   
AM 522 ㎑ ~ 1,620 ㎑ 
 
*External signal 
In/Out terminal 
 
SPEAKER A,B(L, R) 
AUDIO : PHONO, ANALOG(1~5), REC,   
SUBWOOFER OUT 
IR IN/OUT, TRIGGER OUT 
PHONES, USB 
Ethernet(Network) 
 
 
 
 
 
 
 
 
2.2. Additional Information about the EUT 
The EUT consists of the following Subsystems/Modules/Parts: N/A 
 
The test have been performed on the EUT provided with the following 
              modifications : None. 
 
Page of 41
Display

Harman Kardon HK 3700 (serv.man2) EMC - CB Certificate ▷ Download

  • DOWNLOAD Harman Kardon HK 3700 (serv.man2) Service Manual ↓ Size: 1.11 MB | Pages: 41 in PDF or view online for FREE
  • Here you can View online or download the EMC - CB Certificate for the Harman Kardon HK 3700 (serv.man2) in PDF for free, which will help you to disassemble, recover, fix and repair Harman Kardon HK 3700 (serv.man2) Audio. Information contained in Harman Kardon HK 3700 (serv.man2) EMC - CB Certificate (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.