HK3390/230
EMC Test Report
Reference No.:NK08E066
6.3 Test Log
Comment/Performance
No operation errors were detected during and after the test.
No operation errors were detected during and after the test.
Result
Compliant
Point Voltage
Coupling
Result
(Pass/Fail)
HCP, VCP
± 4 kV
Contact Discharge
Pass
RCA Jacks
± 4 kV
Contact Discharge
Pass
Screws
± 4 kV
Contact Discharge
Pass
Enclosure
± 4 kV
Contact Discharge
Pass
Headphone Jack
± 8 kV
Air Discharge
Pass
Front Panel
± 8 kV
Air Discharge
Pass
Buttons
± 8 kV
Air Discharge
Pass
Volume Knob
± 8 kV
Air Discharge
Pass
Stereo Jacks
± 8 kV
Air Discharge
Pass
Anam Electronics Co., Ltd.
Page 11 of 17
HK3390/230
EMC Test Report
Reference No.:NK08E066
7. Radio-frequency, Electromagnetic Field Keyed Carrier Immunity test
7.1 Test Procedure
The tests were performed at 3 m distance in an anechoic chamber.
For floor-standing equipment, the EUT was mounted non-conducting support 0.1 m above the
supporting plane. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor.
The EUT was exposed to the field from different angles, normally 0º, 90º, 180º, 270º and at both horizontal
supporting plane. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor.
The EUT was exposed to the field from different angles, normally 0º, 90º, 180º, 270º and at both horizontal
and vertical polarization(antenna height 1.75 m)
A signal level of 3 V / m, duty cycle 1/8 pulse modulated with a 217 Hz sine wave was applied in the
frequency range 900 MHz. During the test the 1 kHz unwanted noise level comes from the speaker was
detected using microphone and selected level meter
detected using microphone and selected level meter
Instrumentation used during this session:
Instruments Manufacturer
Model
Serial number
Due to Calibration
Signal Generator
R & S
SMY01
830766/032
2008.03
Function Generator
Agilent Tech
33120A
US36042890
2008.12
Power Amplifier
Noiseken
NA25MF1G2010C
A00518
2008.10
Power Sensor
HP
8482A
US37293322
2008.03
Power Sensor
HP
8482A
US37293323
2008.03
Power Meter
HP
E4419B
GB39511164
2008.03
Biconical log
Antenna
Antenna
ARA LPB-2520/A
1180 2008.02
Position Controller
Seo-Young EMC
N/A
N/A
N/A
Turntable Seo-Young
EMC
N/A
N/A N/A
7.2 Test Parameters
Port:
Enclosure
Basic Standard:
EN 61000-4-3:2002+A1:2002
Performance Criteria: A
Performance Results :
A
Test Engineer:
Jin-ha, Ko
Dwell Time:
120 s
Modulation:
Duty Cycle 1/8 PM @ 217 Hz
Frequency Range:
900 MHz
Test Level:
3 V / m
Anam Electronics Co., Ltd.
Page 12 of 17
HK3390/230
EMC Test Report
Reference No.:NK08E066
7.3 Test Log
Frequency
Range (MHz)
Position
(Angle)
Polarity
(H/V)
Field Strength
(V / m)
Modulation
Result
(Pass/Fail)
900 Front
H
3 Duty Cycle 1/8 PM@217 Hz
Pass
900 Rear
H
3 Duty Cycle 1/8 PM@217 Hz
Pass
900 Right
H
3 Duty Cycle 1/8 PM@217 Hz
Pass
900
Left H
3 Duty Cycle 1/8 PM@217 Hz
Pass
900
Front V
3 Duty Cycle 1/8 PM@217 Hz
Pass
900
Rear V
3 Duty Cycle 1/8 PM@217 Hz
Pass
900
Right V
3 Duty Cycle 1/8 PM@217 Hz
Pass
900
Left V
3 Duty Cycle 1/8 PM@217 Hz
Pass
Comment/Performance
The criterion of compliance with the requirement is satisfied with a wanted to unwanted audio signal ratio of
≥
The criterion of compliance with the requirement is satisfied with a wanted to unwanted audio signal ratio of
≥
40 dB at a wanted audio signal level of 500 mV.
Result
Compliant
Anam Electronics Co., Ltd.
Page 13 of 17
HK3390/230
EMC Test Report
Reference No.:NK08E066
8. Fast Transients/Burst
8.1 Test Procedure
The minimum area of the ground reference plane is 1 m x 1 m, and connected to earth via a low
impedance connection.
The EFT/Burst generator was located on the ground reference plane.
impedance connection.
The EFT/Burst generator was located on the ground reference plane.
The EUT was located 0.1 m above the ground reference plane.
The minimum distance between the EUT and all other conductive structures, except the ground
The minimum distance between the EUT and all other conductive structures, except the ground
reference plane is more than 0.5 m.
The test voltage was applied simultaneously between each of the power supply conductors and the
protective earth at the power supply.
Instrumentation used during this session:
The test voltage was applied simultaneously between each of the power supply conductors and the
protective earth at the power supply.
Instrumentation used during this session:
Instruments Manufacturer
Model Serial number
Due to Calibration
EFT/Burst Simulator Noiseken
FNS-AXⅡB50
0199B01147 2008.12
8.2 Test Parameters
Port:
AC Mains
Basic Standard:
EN 61000-4-4:2004
Performance Criteria: B
Performance Results :
A
Test Engineer:
Jin-ha, Ko
Duration:
120 s
Test Data
Tr/Th 5/50 ns
Frep 5 kHz
Trep 300 ms
8.3 Test Log
Line Voltage
Coupling
Inject Time
(sec)
Result
(Pass/Fail)
L1-L2
± 1 kV
Direct 120
Pass
Comment/Performance
No operation errors were detected during and after the test.
No operation errors were detected during and after the test.
Result
Compliant