DOWNLOAD Harman Kardon HK 3390 (serv.man2) Service Manual ↓ Size: 5.81 MB | Pages: 120 in PDF or view online for FREE

Model
HK 3390 (serv.man2)
Pages
120
Size
5.81 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hk-3390-sm2.pdf
Date

Harman Kardon HK 3390 (serv.man2) EMC - CB Certificate ▷ View online

 
Anam Electronics Co., Ltd. 
                                      Page 10 of 17 
HK3390/230 
EMC Test Report
 
         
Reference No.:NK08E066 
6.3 Test Log 
 
 
 
 
 
     
Comment/Performance 
No operation errors were detected during and after the test. 
Result 
    Compliant 
Point Voltage 
Coupling 
Result 
(Pass/Fail) 
HCP, VCP 
± 4 kV 
Contact Discharge 
Pass 
RCA Jacks 
± 4 kV 
Contact Discharge 
Pass 
Screws 
± 4 kV 
Contact Discharge 
Pass 
Enclosure 
± 4 kV 
Contact Discharge 
Pass 
Headphone Jack 
± 8 kV 
Air Discharge 
Pass 
Front Panel 
± 8 kV 
Air Discharge 
Pass 
Buttons 
± 8 kV 
Air Discharge 
Pass 
Volume Knob 
± 8 kV 
Air Discharge 
Pass 
Stereo Jacks 
± 8 kV 
Air Discharge 
Pass 
 
Anam Electronics Co., Ltd. 
                                      Page 11 of 17 
HK3390/230 
EMC Test Report
 
         
Reference No.:NK08E066 
7. Radio-frequency, Electromagnetic Field Keyed Carrier Immunity test 
 
7.1 Test Procedure 
 
The tests were performed at 3 m distance in an anechoic chamber.   
        For floor-standing equipment, the EUT was mounted non-conducting support 0.1 m above the 
        supporting plane. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor. 
        The EUT was exposed to the field from different angles, normally 0º, 90º, 180º, 270º and at both horizontal 
  and vertical polarization(antenna height 1.75 m) 
        A signal level of 3 V / m, duty cycle 1/8 pulse modulated with a 217 Hz sine wave was applied in the   
frequency range 900 MHz. During the test the 1 kHz unwanted noise level comes from the speaker was   
detected using microphone and selected level meter 
        Instrumentation used during this session:
   
Instruments Manufacturer 
Model 
Serial number 
Due to Calibration
Signal Generator 
R & S 
SMY01 
830766/032 
2008.03 
Function Generator
Agilent Tech 
33120A 
US36042890 
2008.12 
Power Amplifier 
Noiseken 
NA25MF1G2010C
A00518 
2008.10 
Power Sensor 
HP 
8482A 
US37293322 
2008.03 
Power Sensor 
HP 
8482A 
US37293323 
2008.03 
Power Meter 
HP 
E4419B 
GB39511164 
2008.03 
Biconical log 
Antenna 
ARA LPB-2520/A 
1180 2008.02 
Position Controller 
Seo-Young EMC
N/A 
N/A 
N/A 
Turntable Seo-Young 
EMC
N/A 
N/A  N/A 
 
7.2 Test Parameters
 
 
 
Port: 
Enclosure 
 
 
Basic Standard: 
EN 61000-4-3:2002+A1:2002 
 
Performance Criteria:  
Performance Results :
Test Engineer: 
Jin-ha, Ko 
 
 
Dwell Time: 
120 s 
Modulation: 
Duty Cycle 1/8 PM @ 217 Hz
Frequency Range: 
900 MHz 
Test Level: 
3 V / m 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Anam Electronics Co., Ltd. 
                                      Page 12 of 17 
HK3390/230 
EMC Test Report
 
         
Reference No.:NK08E066 
7.3 Test Log 
 
Frequency  
Range (MHz) 
Position 
(Angle) 
Polarity
(H/V) 
Field Strength 
(V / m) 
Modulation 
Result 
(Pass/Fail)
900 Front 
3 Duty Cycle 1/8 PM@217 Hz 
Pass 
900 Rear 
3 Duty Cycle 1/8 PM@217 Hz 
Pass 
900 Right 
3 Duty Cycle 1/8 PM@217 Hz 
Pass 
900 
Left H 
3  Duty Cycle 1/8 PM@217 Hz 
Pass 
900 
Front V 
3  Duty Cycle 1/8 PM@217 Hz 
Pass 
900 
Rear V 
3  Duty Cycle 1/8 PM@217 Hz 
Pass 
900 
Right V 
3  Duty Cycle 1/8 PM@217 Hz 
Pass 
900 
Left V 
3  Duty Cycle 1/8 PM@217 Hz 
Pass 
       
Comment/Performance 
The criterion of compliance with the requirement is satisfied with a wanted to unwanted audio signal ratio of   
≥ 
40 dB at a wanted audio signal level of 500 mV. 
Result 
    Compliant 
 
Anam Electronics Co., Ltd. 
                                      Page 13 of 17 
HK3390/230 
EMC Test Report
 
         
Reference No.:NK08E066 
8. Fast Transients/Burst 
 
8.1 Test Procedure 
 
The minimum area of the ground reference plane is 1 m x 1 m, and connected to earth via a low   
impedance connection.   
The EFT/Burst generator was located on the ground reference plane. 
        The EUT was located 0.1 m above the ground reference plane. 
        The minimum distance between the EUT and all other conductive structures, except the ground   
reference plane is more than 0.5 m. 
The test voltage was applied simultaneously between each of the power supply conductors and the   
protective earth at the power supply. 
Instrumentation used during this session: 
 
Instruments Manufacturer 
Model  Serial number
Due to Calibration 
EFT/Burst Simulator  Noiseken 
FNS-AXⅡB50
0199B01147 2008.12 
 
8.2 Test Parameters 
 
Port: 
AC Mains   
 
 
Basic Standard: 
EN 61000-4-4:2004 
Performance Criteria:  
Performance Results : 
Test Engineer: 
Jin-ha, Ko 
Duration: 
120 s 
Test Data 
Tr/Th    5/50 ns 
Frep  5 kHz 
Trep  300 ms 
 
8.3 Test Log 
 
Line Voltage 
Coupling 
Inject Time 
(sec) 
Result  
(Pass/Fail) 
L1-L2 
± 1 kV 
Direct 120 
Pass 
       
Comment/Performance 
No operation errors were detected during and after the test. 
Result 
    Compliant 
Page of 120