Harman Kardon HK 3380 (serv.man10) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 4 of 37 -
Order
No.
14649
TEST REPORT INFORMATION
It should be taken into account that this test report does not replace the text in the test specification.
Only general tests have been mentioned in the pre-printed text. For complete tests and requirements we refer to the
actual specification mentioned.
Only general tests have been mentioned in the pre-printed text. For complete tests and requirements we refer to the
actual specification mentioned.
IEC 60065, 6th edition:1998
The meaning of certain marks and abbreviations (Voltages and currents are r.m.s. values unless otherwise specified)
OK = no remarks
pr
= primary
? = unclear, borderline case
sec
= secondary
∆
t = temperature rise
pr-sec
= primary-secondary
tpr = thermal paper
pr-ss
= primary-static screen
h, m, s = hour, minute, second
pr-ic
= primary-iron core
U, I, P = voltage, current, power
pr-tra
= primary-transformer encl.
û,î = peak value
F
= fuse
n
= rated
PWB
= printed wiring board
= issue considered
LSL
= loudspeaker load
-
IEC 60065, 6th edition : 1998
-
- Page 5 of 37 -
Order
No.
14649
Standardized approval marks
1
SCOPE
According to the standard
2
DEFINITIONS
According to the standard
3
GENERAL REQUIREMENTS
According to the standard
Safety class of the apparatus
Class II
4
GENERAL CONDITIONS FOR
TESTS
TESTS
According to the standard
4.1.4 -
4.2.12.
4.2.12.
Normal operating
conditions/position/adjustments
conditions/position/adjustments
With all users controls set to obtain maximum power from
the mains and at 1/8 of max. audio output power.
Positioned in a test box according to users instruction.
the mains and at 1/8 of max. audio output power.
Positioned in a test box according to users instruction.
5
MARKING AND INSTRUCTIONS
P
Copy of the markings :
SEE ATTACHED PHOTOS
Comprehensible and easily
discernible
discernible
On front and rear side of the enclosure
P
Permanent durability against water
and petroleum spirit
and petroleum spirit
Tested with water / spirit
P
5.1
Identification, maker, model
P
Class II symbol
P
Rated supply voltage and symbol
AC-symbol (
~
) and 230V marked
P
Rated mains frequency
50Hz
P
Rated current or power consumption
200 W
P
5.2
Earth terminal
Class II apparatus
N
Hazardous live terminals
No live parts accessible
P
Supply output terminals (other than
mains)
mains)
The power is marked close to the socket outlet
P
5.3
Use of triangle with exclamation
mark
(Symbol ISO 7000-0434)
Correct symbol applied: Imprinted on rear side in
connection with CAUTION of opening. Further; no
incorrect use of this symbol is found.
connection with CAUTION of opening. Further; no
incorrect use of this symbol is found.
P
5.4
Instructions for use
P
5.4.1
Mains powered equipment not
exposed to dripping or splashing
exposed to dripping or splashing
Adequate instructions supplied.
P
Hazardous live terminals,
instructions for wiring
instructions for wiring
No live terminal.
N
Instructions for replacing lithium
battery
battery
No lithium battery
N
-
IEC 60065, 6th edition : 1998
-
- Page 6 of 37 -
Order
No.
14649
Explanation of marking of the
manually operated mechanical
switch (MOMS)
manually operated mechanical
switch (MOMS)
No MOMS
N
5.4.2
Instructions for permanently
connected equipment
If not completely switched OFF from
the mains, info required
connected equipment
If not completely switched OFF from
the mains, info required
The apparatus is not for permanent connection
N
6 HAZARDOUS
RADIATION
No radiation
N
6.1
High voltage (kV).
N
Focus voltage (kV)
N
Amount of radiation
N
6.2
Non-ionizing radiation (laser
radiation)
radiation)
N
6.2.1
Opening of any cover by hand
N
Mechanical interlocking device
N
Accessible emission normal
operation / classification
operation / classification
N
Labelling
N
6.2.2
Accessible emission fault condition
outside / inside
outside / inside
N
Warning label requirement
N
7
HEATING UNDER NORMAL
OPERATING CONDITIONS
OPERATING CONDITIONS
P
Power consumption in the
OFF/Stand-by mode (ref. 14.6.2)
Position of the functional switch (W)
OFF/Stand-by mode (ref. 14.6.2)
Position of the functional switch (W)
In OFF/Stand-by position, the power consumption is less
than 15W.
than 15W.
P
Surge current needed in clause 14.6
when testing mains switches or
functional switches conductively
connected to the supply mains.
(Note! Mains socket-outlet Clause
14.6.10.)
when testing mains switches or
functional switches conductively
connected to the supply mains.
(Note! Mains socket-outlet Clause
14.6.10.)
Measured and calculated surge current through,
mains relay : 14 A + 20 A = 34 A.
Ref. clause 14.6.
mains relay : 14 A + 20 A = 34 A.
Ref. clause 14.6.
P
-
IEC 60065, 6th edition : 1998
-
- Page 7 of 37 -
Order
No.
14649
7.1
Standby mode:
U
=
207,0
V, I
=
0,007
A, P
=
1,1
W,
Pout =
W
U
=
230,0
V, I
=
0,008
A, P
=
1,3
W,
Pout =
W
U =
254,4
V, I
=
0,009
A, P
=
1,7
W,
Pout =
W
Measured at maximum non-clipped output:
U
=
207,0
V, I
=
2,41
A, P
=
433
W,
Pout =
2 x 57,8
W
(SPK 1)
2 x 58,6
W
(SPK 2)
U
=
230,0
V, I
=
2,58
A, P
=
500
W,
Pout =
2 x 57,8
W
(SPK 1)
2 x 58,6
W
(SPK 2)
U =
254,4
V, I
=
2,62
A, P
=
558
W,
Pout =
2 x 57,8
W
(SPK 1)
2 x 58,6
W
(SPK 2)
LSL =
4 x 8
Ω
Ω
Ω
Ω
Measured at 1/8 of maximum non-clipped output:
U
=
207,0
V, I
=
1,06
A, P
=
172
W,
Pout =
2 x 7,23
W
(SPK 1)
2 x 7,33
W
(SPK 2)
U
=
230,0
V, I
=
1,09
A, P
=
194
W,
Pout =
2 x 7,23
W
(SPK 1)
2 x 7,33
W
(SPK 2)
U =
254,4
V, I
=
1,12
A, P
=
218
W,
Pout =
2 x 7,23
W
(SPK 1)
2 x 7,33
W
(SPK 2)
LSL =
4 x 8
Ω
Ω
Ω
Ω
Operating conditions (power audio amplifier, 1/8 of maximum non clipped output):
U =
254,4
V, I
=
1,12
A, P
=
218
W,
Pout =
2 x 7,23
W
(SPK 1)
2 x 7,33
W
(SPK 2)
LSL =
4 x 8
Ω
Ω
Ω
Ω