<12007721 001> 
 
 
Page 25 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
2.2 
SELV circuits
 
2.2.1 
General requirements 
See below. 
2.2.2 
Voltages under normal conditions (V) ..................:  See appended table. 
2.2.3 
Voltages under fault conditions (V).......................:  See appended table. 
2.2.3.1 
Separation by double or reinforced insulation 
(method 1) 
In accordance with method 1. 
2.2.3.2 
Separation by earthed screen (method 2) 
 
2.2.3.3 
Protection by earthing of the SELV circuit 
(method 3) 
 
2.2.4 
Connection of SELV circuits to other circuits........:  See 2.2.2 and 2.2.3. 
SELV circuit connected to 
primary circuit via one 
bridging capacitor. 
 
2.3 
TNV circuits 
No TNV circuit.
 
 
2.3.1 
Limits 
 
 
Type of TNV circuits .............................................:   
 
2.3.2 
Separation from other circuits and from 
accessible parts 
 
 
Insulation employed..............................................:   
 
2.3.3 
Separation from hazardous voltages 
 
 
Insulation employed..............................................:   
 
2.3.4 
Connection of TNV circuits to other circuits 
 
 
Insulation employed..............................................:   
 
2.3.5 
Test for operating voltages generated externally 
 
 
2.4 
Limited current circuits 
The output connector is accessible to the user and connected to the primary circuit 
by one bridging capacitor (CY2). Therefore, the circuit must be designed as limited 
current circuit. 
2.4.1 
General requirements 
 
2.4.2 
Limit values 
See below 
 
Frequency (Hz) .....................................................:  See appended table 2.4.2. 
 
 
Measured current (mA).........................................:  See appended table 2.4.2. 
 
 
Measured voltage (V) ...........................................:  See appended table 2.4.2. 
 
 
 
<12007721 001> 
 
 
Page 26 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
 
Measured capacitance (
µ
F)..................................:  3300pF 
 
2.4.3 
Connection of limited current circuits to other 
circuits 
Output circuit as limited 
current circuit connected to 
primary via one bridging 
capacitor. 
 
2.5 
Limited power sources 
 
Inherently limited output 
 
 
Impedance limited output 
 
 
Overcurrent protective device limited output 
 
 
Regulating network limited output under normal 
operating and single fault condition 
 
 
Regulating network limited output under normal 
operating conditions and overcurrent protective 
device limited output under single fault condition 
See appended table 2.5. 
 
Output voltage (V), output current (A), apparent 
power (VA)............................................................: 
Complies. 
 
 
Current rating of overcurrent protective device (A)  See pages 12 to 19.  
 
 
2.6 
Provisions for earthing and bonding 
2.6.1 
Protective earthing 
Class II equipment. 
2.6.2 
Functional earthing 
Secondary functional ground 
separated to primary by 
reinforced or double insulation. 
2.6.3 
Protective earthing and protective bonding 
conductors 
 
2.6.3.1 
Size of protective earthing conductors 
No power cord provided. 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG .....................................................................: 
 
 
2.6.3.2 
Size of protective bonding conductors 
 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG .....................................................................: 
 
 
2.6.3.3 
Rated current (A), type and nominal thread 
diameter (mm) ......................................................: 
 
 
Resistance (
) of earthing conductors and their 
terminations, test current (A) ................................: 
 
2.6.3.4 
Colour of insulation ...............................................:   
2.6.4 
Terminals 
 
 
 
<12007721 001> 
 
 
Page 27 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
2.6.4.1 
Protective earthing and bonding terminals 
 
 
Rated current (A), type and nominal thread 
diameter (mm) ......................................................: 
 
 
2.6.4.2 
Separation of the protective earthing conductor 
from protective bonding conductors 
 
2.6.5 
Integrity of protective earthing 
 
2.6.5.1 
Interconnection of equipment 
 
2.6.5.2 
Components in protective earthing conductors 
and protective bonding conductors 
 
2.6.5.3 
Disconnection of protective earth 
 
2.6.5.4 
Parts that can be removed by an operator 
 
2.6.5.5 
Parts removed during servicing 
 
2.6.5.6 
Corrosion resistance 
 
2.6.5.7 
Screws for protective bonding 
 
2.6.5.8 
Reliance on telecommunication network 
No TNV. 
 
2.7 
Overcurrent and earth fault protection in primary circuits 
2.7.1 
Basic requirements 
Equipment relies on 16A rated 
fuse or circuit breaker of the 
wall outlet installation 
protection of the building 
installation in regard to L to N 
short circuit. Over current 
protection is provided by one 
built-in fuse. 
 
Instructions when protection relies on building 
installation 
The protection devices are well 
dimensioned and mounted. 
2.7.2 
Faults not covered in 5.3 (EN 60950: Void) 
Pluggable equipment type A, 
the building installation is 
considered as providing short 
circuit backup protection. 
2.7.3 
Short-circuit backup protection 
Over current protection by one 
built-in fuses. 
2.7.4 
Number and location of protective devices .......... :  One fuse. 
2.7.5 
Protection by several devices 
No service works. 
2.7.6 
Warning to service personnel ............................... :  No service works. 
 
2.8 
Safety interlocks 
No safety interlock.
 
 
 
<12007721 001> 
 
 
Page 28 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
2.8.1 
General principles 
 
2.8.2 
Protection requirements 
 
2.8.3 
Inadvertent reactivation 
 
2.8.4 
Fail-safe operation 
 
2.8.5 
Interlocks with moving parts 
 
2.8.6 
Overriding an interlock 
 
2.8.7 
Switches and relays in interlock systems 
 
2.8.7.1 
Contact gaps (mm)  ..............................................:   
2.8.7.2 
Overload test 
 
2.8.7.3 
Endurance test 
 
2.8.7.4 
Electric strength test (V)  
 
2.8.8 
Mechanical actuators 
 
 
2.9 
Electrical insulation 
2.9.1 
Properties of insulating materials 
Natural rubber, asbestos or 
hygroscopic material is not 
used. 
2.9.2 
Humidity conditioning 
40°C, 95% R.H. for 120h 
2.9.3 
Requirements for insulation 
Insulation comply with sub-
clauses 2.10, 4.5.1 and 5.2. 
2.9.4 
Insulation parameters 
Both parameters were 
considered. 
2.9.5 
Categories of insulation 
The adequate levels of safety 
insulation is provided and 
maintained to comply with the 
requirements of this standard. 
 
2.10 
Clearances, creepage distances and distances through insulation 
2.10.1 
General  
See 2.10.3, 2.10.4 and 
2.10.5. 
2.10.2 
Determination of working voltage 
The rms and the peak voltage 
of the appliance is mains 
voltage 240V max. The unit 
was connected to a 240V TN 
power system. 
2.10.3 
Clearances 
See below and advantage of 
annex G is not considered. 
2.10.3.1 
General 
Considered. 