Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate ▷ View online
<12007721 001>
Page 22 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
1.5.7.2
Bridging resistors
No bridging resistors.
N
1.5.7.3
Accessible parts
See 2.4.
P
1.5.8
Components in equipment for IT power systems
Class II equipment.
N
1.6
Power interface
P
1.6.1
AC power distribution systems
TN power system. IT power
system for Norway.
P
1.6.2
Input current
Highest load according to
1.2.2.1 for this equipment is
the operation with the max.
specified DC-load.
Results see appended table
Results see appended table
P
1.6.3
Voltage limit of hand-held equipment
This appliance is not a hand-
held equipment.
N
1.6.4
Neutral conductor
Class II equipment. Phase
conductors separated to body
by reinforced insulation.
N
1.7
Marking and instructions
P
1.7.1
Power rating
See below.
P
Rated voltage(s) or voltage range(s) (V) .............: AC 100-240V~
P
Symbol for nature of supply for d.c. .....................: Mains from AC source
N
Rated frequency or frequency range (Hz) ............: 47-63Hz
P
Rated current (A) .................................................: 2A MAX.
P
Manufacturer’s name/Trademark ........................: SPEC LIN
P
Type/model ..........................................................: S60-XXXYYY-WZ, S60-
XXXYYY-WZL
(XXX= 090-320, YYY=125-
(XXX= 090-320, YYY=125-
500, Z = H01-H99)
P
Symbol of Class II ................................................: Double square symbol
provided.
P
Other symbols ......................................................: Additional symbols or marking
does not give rise to
misunderstanding.
P
Certification marks ...............................................: See the copy of marking
plate.
N
1.7.2
Safety instructions
User’s manual provided.
P
1.7.3
Short duty cycles
Equipment is designed for
continuous operation.
N
<12007721 001>
Page 23 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
1.7.4
Supply voltage adjustment ...................................: Full range circuit.
N
1.7.5
Power outlets on the equipment ..........................: No outlet.
N
1.7.6
Fuse identification ................................................: Cross reference ”F1” on PCB,
”T3.15A/250V” on manual.
P
1.7.7
Wiring terminals
Appliance inlet used.
N
1.7.7.1
Protective earthing and bonding terminals
Appliance inlet used.
N
1.7.7.2
Terminal for a.c. mains supply conductors
The equipment with appliance
inlet, which is intended to use
the detachable type power
supply cord.
N
1.7.8
Controls and indicators
No safety relevant indicator,
switch or control.
N
1.7.8.1
Identification, location and marking .....................:
N
1.7.8.2
Colours ...............................................................: No safety involve indicator
used.
N
1.7.8.3
Symbols according to IEC 60417 .........................:
N
1.7.8.4
Markings using figures ........................................:
N
1.7.9
Isolation of multiple power sources ......................: Only one main supply.
N
1.7.10
IT power system
For Norway compliance has
to be evaluated during the
national approved.
N
1.7.11
Thermostats and other regulating devices
No adjustable thermostat.
N
1.7.12
Language .............................................................: User’s manual in English.
Marking in English. Versions
of other languages will be
provided when submitted for
national approval.
1.7.13
Durability
The label was subjected to
the permanence of marking
test. The label was rubbed
with cloth soaked with water
for 15 sec. and then again for
15 sec. with the cloth soaked
with petroleum spirit.
After this test there was no
After this test there was no
damage to the label. The
marking on the label did not
fade. There was no curling
nor lifting of the label edge.
P
1.7.14
Removable parts
No removable part.
P
1.7.15
Replaceable batteries
No battery.
N
<12007721 001>
Page 24 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
Language..............................................................:
1.7.16
Operator access with a tool ..................................: No operator accessible area
with a tool.
N
1.7.17
Equipment for restricted access locations ............: Equipment not intended for
use in restricted access
locations.
N
2
PROTECTION FROM HAZARDS
P
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
See 2.1.1.1.
P
2.1.1.1
Access to energized parts
See below.
P
Test by inspection ................................................: No access with test finger and
test pin to any parts with only
basic insulation to ELV or
hazardous voltage. Any
hazardous parts accessible
are unlikely.
P
Test with test finger ..............................................: Ditto
P
Test with test pin ..................................................: Ditto
P
Test with test probe .............................................: No TNV.
N
2.1.1.2
Battery compartments...........................................: No battery compartment.
N
2.1.1.3
Access to ELV wiring
No ELV wiring in operator
accessible area.
N
Working voltage (V); distance (mm) trough
insulation
2.1.1.4
Access to hazardous voltage circuit wiring
No hazardous voltage wiring in
operator accessible area.
N
2.1.1.5
Energy hazards ....................................................: Results see appended table
2.1.1.5.
P
2.1.1.6
Manual controls
No conductive shafts of
operating knobs and handles.
N
2.1.1.7
Discharge of capacitors in the primary circuit
No risk of electric shock, see
below.
P
Time-constant (s); measured voltage (V) .............: Results see appended table
2.1.1.7.
2.1.2
Protection in service access areas
No maintenance work in
operation mode necessary.
N
2.1.3
Protection in restricted access locations
The unit is not intended to be
used in restricted locations
N
<12007721 001>
Page 25 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
2.2
SELV circuits
P
2.2.1
General requirements
See below.
P
2.2.2
Voltages under normal conditions (V) ..................: See appended table.
P
2.2.3
Voltages under fault conditions (V).......................: See appended table.
P
2.2.3.1
Separation by double or reinforced insulation
(method 1)
In accordance with method 1.
P
2.2.3.2
Separation by earthed screen (method 2)
N
2.2.3.3
Protection by earthing of the SELV circuit
(method 3)
N
2.2.4
Connection of SELV circuits to other circuits........: See 2.2.2 and 2.2.3.
SELV circuit connected to
primary circuit via one
bridging capacitor.
P
2.3
TNV circuits
No TNV circuit.
N
2.3.1
Limits
N
Type of TNV circuits .............................................:
2.3.2
Separation from other circuits and from
accessible parts
N
Insulation employed..............................................:
2.3.3
Separation from hazardous voltages
N
Insulation employed..............................................:
2.3.4
Connection of TNV circuits to other circuits
N
Insulation employed..............................................:
2.3.5
Test for operating voltages generated externally
N
2.4
Limited current circuits
The output connector is accessible to the user and connected to the primary circuit
by one bridging capacitor (CY2). Therefore, the circuit must be designed as limited
current circuit.
P
2.4.1
General requirements
P
2.4.2
Limit values
See below
P
Frequency (Hz) .....................................................: See appended table 2.4.2.
Measured current (mA).........................................: See appended table 2.4.2.
Measured voltage (V) ...........................................: See appended table 2.4.2.
Click on the first or last page to see other GO AND PLAY (serv.man4) service manuals if exist.