Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate ▷ View online

 
 
<12007721 001> 
 
 
Page 22 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
1.5.7.2 
Bridging resistors 
No bridging resistors. 
1.5.7.3 
Accessible parts 
See 2.4. 
1.5.8 
Components in equipment for IT power systems 
Class II equipment.  
 
1.6 
Power interface 
1.6.1 
AC power distribution systems 
TN power system. IT power 
system for Norway. 
1.6.2 
Input current 
Highest load according to 
1.2.2.1 for this equipment is 
the operation with the max. 
specified DC-load.  
Results see appended table 
1.6.3 
Voltage limit of hand-held equipment 
This appliance is not a hand-
held equipment. 
1.6.4 
Neutral conductor  
Class II equipment. Phase 
conductors separated to body 
by reinforced insulation. 
 
1.7 
Marking and instructions 
1.7.1 
Power rating  
See below. 
 
Rated voltage(s) or voltage range(s) (V)  .............:  AC 100-240V~ 
 
Symbol for nature of supply for d.c.  .....................:  Mains from AC source 
 
Rated frequency or frequency range (Hz) ............:  47-63Hz 
 
Rated current (A)  .................................................:  2A MAX. 
 
Manufacturer’s name/Trademark  ........................:  SPEC LIN 
 
Type/model  ..........................................................:  S60-XXXYYY-WZ, S60-
XXXYYY-WZL 
(XXX= 090-320, YYY=125-
500, Z = H01-H99) 
 
Symbol of Class II ................................................:  Double square symbol 
provided. 
 
Other symbols ......................................................:  Additional symbols or marking 
does not give rise to 
misunderstanding. 
 
Certification marks ...............................................:  See the copy of marking 
plate. 
1.7.2 
Safety instructions 
User’s manual provided.  
1.7.3 
Short duty cycles 
Equipment is designed for 
continuous operation. 
 
 
<12007721 001> 
 
 
Page 23 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
1.7.4 
Supply voltage adjustment ...................................:  Full range circuit. 
1.7.5 
Power outlets on the equipment  ..........................:  No outlet. 
1.7.6 
Fuse identification ................................................:  Cross reference ”F1” on PCB, 
”T3.15A/250V” on manual. 
1.7.7 
Wiring terminals 
Appliance inlet used. 
1.7.7.1 
Protective earthing and bonding terminals  
Appliance inlet used. 
1.7.7.2 
Terminal for a.c. mains supply conductors 
The equipment with appliance 
inlet, which is intended to use 
the detachable type power 
supply cord. 
1.7.8 
Controls and indicators 
No safety relevant indicator, 
switch or control. 
1.7.8.1 
Identification, location and marking  .....................:   
1.7.8.2 
Colours   ...............................................................:  No safety involve indicator 
used. 
1.7.8.3 
Symbols according to IEC 60417 .........................:   
1.7.8.4 
Markings using figures  ........................................:   
1.7.9 
Isolation of multiple power sources ......................:  Only one main supply. 
1.7.10 
IT power system 
For Norway compliance has 
to be evaluated during the 
national approved. 
1.7.11 
Thermostats and other regulating devices  
No adjustable thermostat. 
1.7.12 
Language .............................................................:  User’s manual in English. 
Marking in English. Versions 
of other languages will be 
provided when submitted for 
national approval. 
 
1.7.13 
Durability 
The label was subjected to 
the permanence of marking 
test. The label was rubbed 
with cloth soaked with water 
for 15 sec. and then again for 
15 sec. with the cloth soaked 
with petroleum spirit. 
After this test there was no 
damage to the label. The 
marking on the label did not 
fade. There was no curling 
nor lifting of the label edge. 
1.7.14 
Removable parts 
No removable part. 
1.7.15 
Replaceable batteries 
No battery. 
 
 
<12007721 001> 
 
 
Page 24 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
 
Language..............................................................:   
 
1.7.16 
Operator access with a tool ..................................:  No operator accessible area 
with a tool. 
1.7.17 
Equipment for restricted access locations ............:  Equipment not intended for 
use in restricted access 
locations. 
 
PROTECTION FROM HAZARDS 
2.1 
Protection from electric shock and energy hazards 
2.1.1 
Protection in operator access areas  
See  2.1.1.1. 
2.1.1.1 
Access to energized parts 
See below. 
 
Test by inspection ................................................:  No access with test finger and 
test pin to any parts with only 
basic insulation to ELV or 
hazardous voltage. Any 
hazardous parts accessible 
are unlikely.  
 
Test with test finger ..............................................:  Ditto 
 
Test with test pin ..................................................:  Ditto 
 
Test with test probe  .............................................:  No TNV. 
2.1.1.2 
Battery compartments...........................................:  No battery compartment. 
2.1.1.3 
Access to ELV wiring 
No ELV wiring in operator 
accessible area. 
 
Working voltage (V); distance (mm) trough 
insulation 
 
 
2.1.1.4 
Access to hazardous voltage circuit wiring 
No hazardous voltage wiring in 
operator accessible area. 
2.1.1.5 
Energy hazards ....................................................:  Results see appended table 
2.1.1.5. 
2.1.1.6 
Manual controls 
No conductive shafts of 
operating knobs and handles. 
2.1.1.7 
Discharge of capacitors in the primary circuit 
No risk of electric shock, see 
below. 
 
Time-constant (s); measured voltage (V) .............:  Results see appended table 
2.1.1.7. 
 
2.1.2 
Protection in service access areas 
No maintenance work in 
operation mode necessary. 
2.1.3 
Protection in restricted access locations 
The unit is not intended to be 
used in restricted locations 
 
 
 
<12007721 001> 
 
 
Page 25 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
2.2 
SELV circuits
 
2.2.1 
General requirements 
See below. 
2.2.2 
Voltages under normal conditions (V) ..................:  See appended table. 
2.2.3 
Voltages under fault conditions (V).......................:  See appended table. 
2.2.3.1 
Separation by double or reinforced insulation 
(method 1) 
In accordance with method 1. 
2.2.3.2 
Separation by earthed screen (method 2) 
 
2.2.3.3 
Protection by earthing of the SELV circuit 
(method 3) 
 
2.2.4 
Connection of SELV circuits to other circuits........:  See 2.2.2 and 2.2.3. 
SELV circuit connected to 
primary circuit via one 
bridging capacitor. 
 
2.3 
TNV circuits 
No TNV circuit.
 
 
2.3.1 
Limits 
 
 
Type of TNV circuits .............................................:   
 
2.3.2 
Separation from other circuits and from 
accessible parts 
 
 
Insulation employed..............................................:   
 
2.3.3 
Separation from hazardous voltages 
 
 
Insulation employed..............................................:   
 
2.3.4 
Connection of TNV circuits to other circuits 
 
 
Insulation employed..............................................:   
 
2.3.5 
Test for operating voltages generated externally 
 
 
2.4 
Limited current circuits 
The output connector is accessible to the user and connected to the primary circuit 
by one bridging capacitor (CY2). Therefore, the circuit must be designed as limited 
current circuit. 
2.4.1 
General requirements 
 
2.4.2 
Limit values 
See below 
 
Frequency (Hz) .....................................................:  See appended table 2.4.2. 
 
 
Measured current (mA).........................................:  See appended table 2.4.2. 
 
 
Measured voltage (V) ...........................................:  See appended table 2.4.2. 
 