DOWNLOAD Harman Kardon GO AND PLAY (serv.man4) Service Manual ↓ Size: 2.46 MB | Pages: 127 in PDF or view online for FREE

Model
GO AND PLAY (serv.man4)
Pages
127
Size
2.46 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
go-and-play-sm4.pdf
Date

Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate ▷ View online

 
 
<12007721 001> 
 
 
Page 21 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
GENERAL 
1.5 
Components 
1.5.1 
Comply with IEC 60950 or relevant component 
standard 
Components which were 
found to affect safety aspects 
comply with the requirements 
of this standard or within the 
safety aspects of the relevant 
IEC component standards. 
(see appended table 1.5.1) 
1.5.2 
Evaluation and testing of components 
Components which are 
certified to IEC and /or 
national standards are used 
correctly within their ratings. 
Components not covered by 
IEC standards are tested 
under the conditions present 
in the equipment. 
 
Dimensions (mm) of mains plug for direct plug-in :  Not direct plug in type. 
 
Torque and pull test of mains plug for direct 
plug-in; torque (Nm); pull (N) ................................: 
 
1.5.3 
Thermal controls 
 
1.5.4 
Transformers 
Transformer used is suitable 
for its intended application and 
comply with the relevant 
requirements of the standard 
and particularly Annex C. 
1.5.5 
Interconnecting cables 
Interconnection o/p cable to 
other device is carrying only 
SELV on an energy level 
below 240VA. 
 Except the insulation 
material, there are no further 
requirements to the o/p 
interconnection cable. 
1.5.6 
Capacitors in primary circuits ............................... :  Between lines: X2 capacitor 
according to IEC 60384-
14:1993 with 21 days damp 
heat test. 
1.5.7 
Double or reinforced insulation bridged by 
components 
See below. 
1.5.7.1 
Bridging capacitors 
Primary and secondary 
bridged by one capacitor 
(CY2), which used was 
certified as Y1 capacitor 
according to IEC 60384-
14/1993. 
 
 
<12007721 001> 
 
 
Page 22 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
1.5.7.2 
Bridging resistors 
No bridging resistors. 
1.5.7.3 
Accessible parts 
See 2.4. 
1.5.8 
Components in equipment for IT power systems 
Class II equipment.  
 
1.6 
Power interface 
1.6.1 
AC power distribution systems 
TN power system. IT power 
system for Norway. 
1.6.2 
Input current 
Highest load according to 
1.2.2.1 for this equipment is 
the operation with the max. 
specified DC-load.  
Results see appended table 
1.6.3 
Voltage limit of hand-held equipment 
This appliance is not a hand-
held equipment. 
1.6.4 
Neutral conductor  
Class II equipment. Phase 
conductors separated to body 
by reinforced insulation. 
 
1.7 
Marking and instructions 
1.7.1 
Power rating  
See below. 
 
Rated voltage(s) or voltage range(s) (V)  .............:  AC 100-240V~ 
 
Symbol for nature of supply for d.c.  .....................:  Mains from AC source 
 
Rated frequency or frequency range (Hz) ............:  47-63Hz 
 
Rated current (A)  .................................................:  2A MAX. 
 
Manufacturer’s name/Trademark  ........................:  SPEC LIN 
 
Type/model  ..........................................................:  S60-XXXYYY-WZ, S60-
XXXYYY-WZL 
(XXX= 090-320, YYY=125-
500, Z = H01-H99) 
 
Symbol of Class II ................................................:  Double square symbol 
provided. 
 
Other symbols ......................................................:  Additional symbols or marking 
does not give rise to 
misunderstanding. 
 
Certification marks ...............................................:  See the copy of marking 
plate. 
1.7.2 
Safety instructions 
User’s manual provided.  
1.7.3 
Short duty cycles 
Equipment is designed for 
continuous operation. 
 
 
<12007721 001> 
 
 
Page 23 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
1.7.4 
Supply voltage adjustment ...................................:  Full range circuit. 
1.7.5 
Power outlets on the equipment  ..........................:  No outlet. 
1.7.6 
Fuse identification ................................................:  Cross reference ”F1” on PCB, 
”T3.15A/250V” on manual. 
1.7.7 
Wiring terminals 
Appliance inlet used. 
1.7.7.1 
Protective earthing and bonding terminals  
Appliance inlet used. 
1.7.7.2 
Terminal for a.c. mains supply conductors 
The equipment with appliance 
inlet, which is intended to use 
the detachable type power 
supply cord. 
1.7.8 
Controls and indicators 
No safety relevant indicator, 
switch or control. 
1.7.8.1 
Identification, location and marking  .....................:   
1.7.8.2 
Colours   ...............................................................:  No safety involve indicator 
used. 
1.7.8.3 
Symbols according to IEC 60417 .........................:   
1.7.8.4 
Markings using figures  ........................................:   
1.7.9 
Isolation of multiple power sources ......................:  Only one main supply. 
1.7.10 
IT power system 
For Norway compliance has 
to be evaluated during the 
national approved. 
1.7.11 
Thermostats and other regulating devices  
No adjustable thermostat. 
1.7.12 
Language .............................................................:  User’s manual in English. 
Marking in English. Versions 
of other languages will be 
provided when submitted for 
national approval. 
 
1.7.13 
Durability 
The label was subjected to 
the permanence of marking 
test. The label was rubbed 
with cloth soaked with water 
for 15 sec. and then again for 
15 sec. with the cloth soaked 
with petroleum spirit. 
After this test there was no 
damage to the label. The 
marking on the label did not 
fade. There was no curling 
nor lifting of the label edge. 
1.7.14 
Removable parts 
No removable part. 
1.7.15 
Replaceable batteries 
No battery. 
 
 
<12007721 001> 
 
 
Page 24 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
 
Language..............................................................:   
 
1.7.16 
Operator access with a tool ..................................:  No operator accessible area 
with a tool. 
1.7.17 
Equipment for restricted access locations ............:  Equipment not intended for 
use in restricted access 
locations. 
 
PROTECTION FROM HAZARDS 
2.1 
Protection from electric shock and energy hazards 
2.1.1 
Protection in operator access areas  
See  2.1.1.1. 
2.1.1.1 
Access to energized parts 
See below. 
 
Test by inspection ................................................:  No access with test finger and 
test pin to any parts with only 
basic insulation to ELV or 
hazardous voltage. Any 
hazardous parts accessible 
are unlikely.  
 
Test with test finger ..............................................:  Ditto 
 
Test with test pin ..................................................:  Ditto 
 
Test with test probe  .............................................:  No TNV. 
2.1.1.2 
Battery compartments...........................................:  No battery compartment. 
2.1.1.3 
Access to ELV wiring 
No ELV wiring in operator 
accessible area. 
 
Working voltage (V); distance (mm) trough 
insulation 
 
 
2.1.1.4 
Access to hazardous voltage circuit wiring 
No hazardous voltage wiring in 
operator accessible area. 
2.1.1.5 
Energy hazards ....................................................:  Results see appended table 
2.1.1.5. 
2.1.1.6 
Manual controls 
No conductive shafts of 
operating knobs and handles. 
2.1.1.7 
Discharge of capacitors in the primary circuit 
No risk of electric shock, see 
below. 
 
Time-constant (s); measured voltage (V) .............:  Results see appended table 
2.1.1.7. 
 
2.1.2 
Protection in service access areas 
No maintenance work in 
operation mode necessary. 
2.1.3 
Protection in restricted access locations 
The unit is not intended to be 
used in restricted locations 
 
Page of 127