August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
8 of 80
1.2.2. Immunity Test Summary
Test Methods
Minimum Criterion
Level Required
as per EN 55024
Criterion Level
Tested
Compliance
Status
IEC 61000-4-2: 1995/A1:
1998/A2: 2000
1998/A2: 2000
- ESD Immunity
Criterion B
±8 kV air discharge,
±4 kV contact discharge
Criterion B
±8 kV Air Discharge,
±4 kV Contact Discharge
PASS
IEC 61000-4-3: 2006 -
Radio Frequency
Immunity
Immunity
Criterion A
3 V/m from 80-1000 MHz
(80% AM at 1kHz)
Criterion A
3 V/m from 80-1000 MHz
(80% AM at 1kHz)
PASS
IEC 61000-4-4: 2004
-Electrical Fast Transient
-Electrical Fast Transient
Immunity
Criterion B
Power line pulses of ± 1 kV;
I/O line pulses of ± 0.5 kV
Criterion B
Power Line Pulses of ± 1 kV;
up to ±2kV process/control lines;
I/O Line Pulses of ± 0.5 kV
PASS
IEC 61000-4-5: 2005
-Surge Immunity
-Surge Immunity
Criterion B
±2kV common mode surges,
±1kV differential mode surges
Criterion B
±2kV Common Mode Surges,
±1kV Differential Mode
Surges
PASS
IEC 61000-4-6: 2003/A1:
2004/A2: 2006
-RF Common Mode
2004/A2: 2006
-RF Common Mode
Immunity
Criterion A
150 kHz - 80 MHz at 3 Vrms
1 kHz 80% amplitude modulated
Criterion A
150 kHz - 80 MHz at 3 Vrms
1kHz 80% amplitude modulated
PASS
IEC 61000-4-8: 1993/A1:
2000
Power Frequency Magnetic
Field
Field
Criterion A
Helmholtz coil at 50 Hz,
to 1 Amp (rms) per meter
Criterion A
Helmholtz coil at 50 Hz,
to 1 Amp (rms) per meter
PASS
IEC 61000-4-11: 2004
- Voltage Dips and Short
- Voltage Dips and Short
Interruptions
Criterion B and C
Voltage Dips of 30% and >95%;
Interruptions of >95%.
Criterion B and C
Voltage Dips of 30% and
>95%; Interruptions of >95%.
PASS
Test Supervisor:
Mike Krumweide, Nemko USA, Inc.
Refer to the test results section for further details.
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
9 of 80
2. SYSTEM
CONFIGURATION
2.1. System Components and Power Cables
DEVICE
MANUFACTURER
MODEL #
SERIAL #
POWER CABLE
EUT - Audio/Peripheral System
Harman Multimedia
Model # Go + Play
Serial #: N/A
Model # Go + Play
Serial #: N/A
24 VDC from power
supply
supply
EUT - Power Supply
SPEC LIN
Model #: S60-180333-WH01
Serial #: N/A
Model #: S60-180333-WH01
Serial #: N/A
1.5m, unshielded,
18AWG, Two prong plug
Support – CD Player
Panasonic
Model#:”SL-S200”
Serial#:FA8DF72606
Model#:”SL-S200”
Serial#:FA8DF72606
1m modified, unshielded
Input: AC115V 3W 50-
Input: AC115V 3W 50-
60Hz
Output: DC2.4V 300mA
2.2. Device Interconnection and I/O Cables
CONNECTION
I/O CABLE
S- Video Cable
2m, unterminated
Audio Mini-plug
1.5m, unterminated
USB Cable
2m, unterminated
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
10 of 80
2.3. Description and Method of Exercising the EUT
The Go + Play is an Audio/Peripheral System. Its function is play music from an Apple
IPOD or another digital music source. The EUT was exercised by playing pink noise
provided from a support CD player. An un-recoverable audio disruption or loss of controls
or functions during immunity tests as indicated by audible reception or failing to respond to
manual control functions would indicate a failure.
2.4. Design Modifications for Compliance
Device: Audio/Peripheral System
Model: Go + Play
The following design modifications were made to the EUT during testing.
No design modifications were made to the EUT during testing.
Model: Go + Play
The following design modifications were made to the EUT during testing.
No design modifications were made to the EUT during testing.
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
11 of 80
3. DESCRIPTION OF TEST SITE AND EQUIPMENT
3.1. Description of Test Site
The test site is located at 11696 Sorrento Valley Road, Suite F, San Diego, CA 92121. The site is physically
located 18 miles Northwest of downtown San Diego. The general area is a valley 1.5 miles east of the Pacific
Ocean. This particular part of the valley tends to minimize ambient levels, i.e. radio and TV broadcast
stations and land mobile communications. The three and ten-meter Open Area Test Site (OATS) is located
behind the office/lab building. It conforms to the normalized site attenuation limits and construction
specifications as set in the EN 55022: 1998/A1: 2000/A2: 2003, CISPR 16: 2003 and ANSI C63.4: 2003
documents. The OATS normalized site attenuation characteristics are verified for compliance every year, and
registered with the Federal Communications Commission under Registration Number 90579.
4. DESCRIPTION OF TESTING METHODS
4.1. Introduction
Nemko USA, Inc. is accredited to ISO/IEC 17025 by the National Voluntary Laboratory Accreditation
Program (NVLAP) for Electromagnetic Compatibility and Telecommunications testing. Part of the
accreditation process involves the demonstration of competence in various test methods.
Prior to the beginning of work, Nemko personnel work with their clients to ensure the proper test standards
and test methods are utilized. Applicable tests and the minimum criteria for a pass condition are listed in the
administrative section of this report.
Click on the first or last page to see other GO AND PLAY (serv.man3) service manuals if exist.