DOWNLOAD Harman Kardon GO AND PLAY (serv.man3) Service Manual ↓ Size: 3.09 MB | Pages: 80 in PDF or view online for FREE

Model
GO AND PLAY (serv.man3)
Pages
80
Size
3.09 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
go-and-play-sm3.pdf
Date

Harman Kardon GO AND PLAY (serv.man3) EMC - CB Certificate ▷ View online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
8 of 80 
 
 
1.2.2.  Immunity Test Summary 
 
 
Test Methods 
 
Minimum Criterion  
Level Required  
as per EN 55024 
 
Criterion Level 
Tested 
Compliance 
Status 
IEC 61000-4-2: 1995/A1: 
1998/A2: 2000
 
- ESD Immunity 
Criterion B 
±8 kV air discharge,  
±4 kV contact discharge 
Criterion B 
±8 kV Air Discharge,  
±4 kV Contact Discharge 
PASS 
IEC 61000-4-3: 2006 -
Radio Frequency 
Immunity 
Criterion A  
3 V/m from 80-1000 MHz  
(80% AM at 1kHz) 
Criterion A  
3 V/m from 80-1000 MHz  
(80% AM at 1kHz) 
PASS 
IEC 61000-4-4: 2004 
-Electrical Fast Transient 
Immunity 
Criterion B 
Power line pulses of ± 1 kV; 
I/O line pulses of ± 0.5 kV 
Criterion B 
Power Line Pulses of ± 1 kV; 
up to ±2kV process/control lines; 
I/O Line Pulses of ± 0.5 kV 
PASS 
IEC 61000-4-5: 2005 
-Surge Immunity 
Criterion B 
±2kV common mode surges, 
±1kV differential mode surges 
Criterion B 
±2kV Common Mode Surges,  
±1kV Differential Mode 
Surges 
PASS 
IEC 61000-4-6: 2003/A1: 
2004/A2: 2006 
-RF Common Mode 
Immunity 
Criterion A 
150 kHz - 80 MHz at 3 Vrms 
1 kHz 80% amplitude modulated 
Criterion A 
150 kHz - 80 MHz at 3 Vrms 
1kHz 80% amplitude modulated 
PASS 
IEC 61000-4-8: 1993/A1: 
2000
 
Power Frequency Magnetic 
Field 
Criterion A 
Helmholtz coil at 50 Hz, 
to 1 Amp (rms) per meter 
Criterion A 
Helmholtz coil at 50 Hz, 
to 1 Amp (rms) per meter 
PASS 
IEC 61000-4-11: 2004 
- Voltage Dips and Short 
Interruptions 
Criterion B and C 
Voltage Dips of 30% and >95%; 
Interruptions of >95%. 
Criterion B and C 
Voltage Dips of 30% and 
>95%; Interruptions of >95%. 
PASS 
 
 
 
Test Supervisor
 
Mike Krumweide, Nemko USA, Inc. 
Refer to the test results section for further details
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
9 of 80 
 
2. SYSTEM 
CONFIGURATION 
2.1.  System Components and Power Cables 
 
 
DEVICE 
MANUFACTURER 
MODEL # 
SERIAL # 
 
POWER CABLE 
EUT - Audio/Peripheral System 
 
Harman Multimedia 
Model # Go + Play 
Serial #: N/A 
24 VDC from power 
supply 
EUT - Power Supply 
 
SPEC LIN 
Model #: S60-180333-WH01 
Serial #: N/A 
1.5m, unshielded, 
18AWG, Two prong plug 
Support – CD Player 
Panasonic 
Model#:”SL-S200” 
Serial#:FA8DF72606 
1m modified, unshielded 
Input: AC115V 3W 50-
60Hz 
Output: DC2.4V 300mA 
 
 
 
2.2.  Device Interconnection and I/O Cables 
 
CONNECTION 
I/O CABLE 
S- Video Cable 
2m, unterminated 
Audio Mini-plug 
1.5m, unterminated 
USB Cable 
2m, unterminated 
 
 
 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
10 of 80 
 
 
2.3.  Description and Method of Exercising the EUT 
 
 
The Go + Play is an Audio/Peripheral System.  Its function is play music from an Apple 
IPOD or another digital music source. The EUT was exercised by playing pink noise 
provided from a support CD player.  An un-recoverable audio disruption or loss of controls 
or functions during immunity tests as indicated by audible reception or failing to respond to 
manual control functions would indicate a failure.   
 
2.4.  Design Modifications for Compliance 
 
Device: Audio/Peripheral System 
Model:  Go + Play 
 
The following design modifications were made to the EUT during testing. 
 
 
No design modifications were made to the EUT during testing. 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
11 of 80 
 
 
3.  DESCRIPTION OF TEST SITE AND EQUIPMENT 
3.1.  Description of Test Site 
 
The test site is located at 11696 Sorrento Valley Road, Suite F, San Diego, CA 92121.  The site is physically 
located 18 miles Northwest of downtown San Diego.  The general area is a valley 1.5 miles east of the Pacific 
Ocean.  This particular part of the valley tends to minimize ambient levels, i.e. radio and TV broadcast 
stations and land mobile communications.  The three and ten-meter Open Area Test Site (OATS) is located 
behind the office/lab building.  It conforms to the normalized site attenuation limits and construction 
specifications as set in the EN 55022: 1998/A1: 2000/A2: 2003, CISPR 16: 2003 and ANSI C63.4: 2003 
documents. The OATS normalized site attenuation characteristics are verified for compliance every year, and 
registered with the Federal Communications Commission under Registration Number 90579. 
 
 
4.  DESCRIPTION OF TESTING METHODS 
4.1. Introduction 
 
Nemko USA, Inc. is accredited to ISO/IEC 17025 by the National Voluntary Laboratory Accreditation 
Program (NVLAP) for Electromagnetic Compatibility and Telecommunications testing.  Part of the 
accreditation process involves the demonstration of competence in various test methods. 
 
Prior to the beginning of work, Nemko personnel work with their clients to ensure the proper test standards 
and test methods are utilized.  Applicable tests and the minimum criteria for a pass condition are listed in the 
administrative section of this report. 
 
Page of 80
Display

Click on the first or last page to see other GO AND PLAY (serv.man3) service manuals if exist.