Harman Kardon ESQUIRE (serv.man4) EMC - CB Certificate ▷ View online
Report No.: EM201300418-2 Application No.: ZJ00031163 Page 25 of 63
Project No.:
ZJ00031163
Polarziation:
Vertical
Standard:
(RE)EN55022 class B
_3m_1-6GHz_PK
_3m_1-6GHz_PK
Power Source:
AC 230V/50Hz
Test item:
Radiation Test
Date:
2013-7-2
Temp./Hum.(%RH): 21/56%RH
Time:
21:57:10
EUT:
Portable Wireless speaker with
Distance:
3m
Model:
HARMAN KARDON ESQUIRE
Test Result:
Pass
Note:
Mode 4:BT(battery)
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBuV/m)
Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
1
1633.967
33.96 12.39 46.35 70.00
-23.65 peak
2
1633.967
18.91 12.39 31.30 50.00
-18.70 AVG
3
1832.841
35.74 13.45 49.19 70.00
-20.81 peak
4
1832.841
17.75 13.45 31.20 50.00
-18.80 AVG
5
2015.009
34.81 14.14 48.95 70.00
-21.05 peak
6
2015.009
16.36 14.14 30.50 50.00
-19.50 AVG
7
3457.165
31.16 24.11 55.27 74.00
-18.73 peak
8
3457.165
17.19 24.11 41.30 54.00
-12.70 AVG
9
4823.657
29.67 27.77 57.44 74.00
-16.56 peak
10
4823.657
17.03 27.77 44.80 54.00 -9.20 AVG
11
5552.406
28.20 27.74 55.94 74.00
-18.06 peak
12
5552.406
15.86 27.74 43.60 54.00
-10.40 AVG
Report No.: EM201300418-2 Application No.: ZJ00031163 Page 26 of 63
Project No.:
ZJ00031163
Polarziation:
Horizontal
Standard: (RE)EN55022_class
B_3m
Power Source:
AC 230V/50Hz
Test item:
Radiation Test
Date:
2013-7-2
Temp./Hum.(%RH): 21/56%RH
Time:
14:47:38
EUT:
Portable Wireless speaker with
Distance:
3m
Model:
HARMAN KARDON ESQUIRE
Test Result:
Pass
Note:
Mode 4:BT(battery)
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBuV/m)
Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
1 85.8019 4.22 9.18 13.40 40.00 -26.60
QP
2 110.4891 4.24
9.46 13.70 40.00 -26.30
QP
3 237.2625 5.02 13.18 18.20 47.00 -28.80
QP
4 295.3990 7.89 14.91 22.80 47.00 -24.20
QP
5
319.5776
14.00 16.20 30.20 47.00
-16.80 QP
6 353.5944 9.35 17.35 26.70 47.00 -20.30
QP
Report No.: EM201300418-2 Application No.: ZJ00031163 Page 27 of 63
Project No.:
ZJ00031163
Polarziation:
Horizontal
Standard:
(RE)EN55022 class B
_3m_1-6GHz_PK
_3m_1-6GHz_PK
Power Source:
AC 230V/50Hz
Test item:
Radiation Test
Date:
2013-7-2
Temp./Hum.(%RH): 21/56%RH
Time:
21:53:40
EUT:
Portable Wireless speaker with
Distance:
3m
Model:
HARMAN KARDON ESQUIRE
Test Result:
Pass
Note:
Mode 4:BT(battery)
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBuV/m)
Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
1
1638.666
33.15 12.41 45.56 70.00
-24.44 peak
2
1638.666
19.39 12.41 31.80 50.00
-18.20 AVG
3
1832.841
32.88 13.45 46.33 70.00
-23.67 peak
4
1832.841
17.75 13.45 31.20 50.00
-18.80 AVG
5
2015.009
34.63 14.14 48.77 70.00
-21.23 peak
6
2015.009
17.56 14.14 31.70 50.00
-18.30 AVG
7
3283.019
30.13 24.00 54.13 74.00
-19.87 peak
8
3283.019
16.50 24.00 40.50 54.00
-13.50 AVG
9
3703.813
30.67 24.71 55.38 74.00
-18.62 peak
10
3703.813
19.09 24.71 43.80 54.00
-10.20 AVG
11
4851.438
29.51 27.84 57.35 74.00
-16.65 peak
12
4851.438
17.86 27.84 45.70 54.00 -8.30 AVG
Report No.: EM201300418-2 Application No.: ZJ00031163 Page 28 of 63
4.2 CONDUCTED EMISSION MEASUREMENT
4.2.1 LIMITS
AC Power port
Frequency (MHz)
Quasi-peak(dBμV)
Average(dBμV)
0.15 ~ 0.5
66~56 56~46
0.5 ~ 5
56 46
5 ~ 30
60 50
NOTE:
(1) The lower limit shall apply at the transition frequencies.
(2) The limit decreases in line with the logarithm of the frequency in the range of 0.15 ~0.5 MHz.
Telecommunication ports
Frequency (MHz)
Quasi-peak(dBμV)
Average(dBμV)
0.15 ~ 0.5
84~74 74~64
0.5 ~ 30
74 64
NOTE:
(1) The lower limit shall apply at the transition frequencies.
(2) The limit decreases in line with the logarithm of the frequency in the range of 0.15 ~0.5 MHz.
Telecommunication ports
4.2.2 TEST PROCEDURES
Procedure of Preliminary Test
For measurement of the disturbance voltage the equipment under test (EUT) is connected to
the power supply mains and any other extended network via one or more artificial network(s).
An EUT, whether intended to be grounded or not, and which is to be used on a table is
configured as follows:
– Either the bottom or the rear of the EUT shall be at a controlled distance of 40 cm from a
reference ground plane. This ground plane is normally the wall or floor of a shielded room. It
may also be a grounded metal plane of at least 2 m by 2 m. This is physically accomplished as
follows:
1) place the EUT on a table of non-conducting material which is at least 80 cm high. Place the
EUT so that it is 40 cm from the wall of the shielded room, or
2) place the EUT on a table of non-conducting material which is 40 cm high so that the
bottom of the EUT is 40 cm above the ground plane;
– All other conductive surfaces of the EUT shall be at least 80 cm from the reference ground
plane;
– The ANs are placed on the floor that one side of the AN housings is 40 cm from the
vertical reference ground plane and other metallic parts;
– Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded
back and forth forming a bundle 30 cm to 40 cm long, hanging approximately in the middle
between the ground plane and the table.
– I/O cables that are connected to a peripheral shall be bundled in the centre. The end of the
cable may be terminated if required using correct terminating impedance. The total length
shall not exceed 1 m.
The test mode(s) described in Item 2.4 were scanned during the preliminary test. After the
preliminary scan, we found the test mode described in Item 2.4 producing the highest
emission level. The EUT configuration and cable configuration of the above highest emission
For measurement of the disturbance voltage the equipment under test (EUT) is connected to
the power supply mains and any other extended network via one or more artificial network(s).
An EUT, whether intended to be grounded or not, and which is to be used on a table is
configured as follows:
– Either the bottom or the rear of the EUT shall be at a controlled distance of 40 cm from a
reference ground plane. This ground plane is normally the wall or floor of a shielded room. It
may also be a grounded metal plane of at least 2 m by 2 m. This is physically accomplished as
follows:
1) place the EUT on a table of non-conducting material which is at least 80 cm high. Place the
EUT so that it is 40 cm from the wall of the shielded room, or
2) place the EUT on a table of non-conducting material which is 40 cm high so that the
bottom of the EUT is 40 cm above the ground plane;
– All other conductive surfaces of the EUT shall be at least 80 cm from the reference ground
plane;
– The ANs are placed on the floor that one side of the AN housings is 40 cm from the
vertical reference ground plane and other metallic parts;
– Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded
back and forth forming a bundle 30 cm to 40 cm long, hanging approximately in the middle
between the ground plane and the table.
– I/O cables that are connected to a peripheral shall be bundled in the centre. The end of the
cable may be terminated if required using correct terminating impedance. The total length
shall not exceed 1 m.
The test mode(s) described in Item 2.4 were scanned during the preliminary test. After the
preliminary scan, we found the test mode described in Item 2.4 producing the highest
emission level. The EUT configuration and cable configuration of the above highest emission
Click on the first or last page to see other ESQUIRE (serv.man4) service manuals if exist.