Harman Kardon ESQUIRE (serv.man3) EMC - CB Certificate ▷ View online
Report No.:
EM201300418-1
Application No.:
ZJ00031163
Page 17 of 58
4.2 FREQUENCY RANGE
4.2.1 LIMITS
EN300 328 clause 4.3.3
fL > 2,4 GHz and fH < 2,4835 GHz
4.2.2 TEST PROCEDURE
Test EUT in normal conditions, and then repeat in extreme conditions.
Measurement RBW = 100 kHz, VBW ≥ 100 kHz, average mode with 60 second sweeps selected.
Pre-test the 3 modulation to find GFSK and 8DPSK is worse case, so only record GFSK and
8DPSK test data.
4.2.3 TEST SETUP
Test EUT in normal conditions, and then repeat in extreme conditions.
Measurement RBW = 100 kHz, VBW ≥ 100 kHz, average mode with 60 second sweeps selected.
Pre-test the 3 modulation to find GFSK and 8DPSK is worse case, so only record GFSK and
8DPSK test data.
4.2.3 TEST SETUP
4.2.4 TEST RESULTS
Measurement Conditions
Frequency spot with
level ≤ -30dBm/100KHz
level ≤ -30dBm/100KHz
Limit (MHz)
Temperature(°C) Voltage
FL
FH
Lower
Higher
For GFSK
AC Power
25 ACnom
2400.93
2481.02
FL>2400.0 FH< 2483.5
-20
ACmin 2400.96
2481.01
ACmax 2401.01 2480.99
+55
ACmin 2400.95
2481.04
ACmax 2400.99 2480.98
For 8DPSK
AC Power
25 ACnom
25 ACnom
2400.41
2480.79
FL>2400.0 FH< 2483.5
-20
ACmin 2400.41
2480.80
ACmax 2400.37 2480.73
+55
ACmin 2400.36
2480.78
ACmax 2400.40 2480.76
Antenna
EUT
Receiver
Report No.:
EM201300418-1
Application No.:
ZJ00031163
Page 18 of 58
FL: Lowest frequency of the power envelope, it is the frequency furthest below the frequency
of maximum power where the output power drops below the level of –80 dBm/Hz spectral
power density (-30 dBm if measured in a 100 kHz bandwidth) eirp.
FH: Highest frequency of the power envelope, it is the frequency furthest above the frequency
of maximum power where the output power drops below the level of –80 dBm/Hz spectral
power density (-30 dBm if measured in a 100 kHz bandwidth) eirp.
NOTE: ACnom =AC230V/50Hz;ACmin = AC207V/50Hz; ACmax= AC253V/50Hz
TEST RESULTS: The unit does meet the requirements.
of maximum power where the output power drops below the level of –80 dBm/Hz spectral
power density (-30 dBm if measured in a 100 kHz bandwidth) eirp.
FH: Highest frequency of the power envelope, it is the frequency furthest above the frequency
of maximum power where the output power drops below the level of –80 dBm/Hz spectral
power density (-30 dBm if measured in a 100 kHz bandwidth) eirp.
NOTE: ACnom =AC230V/50Hz;ACmin = AC207V/50Hz; ACmax= AC253V/50Hz
TEST RESULTS: The unit does meet the requirements.
The test slots as below:
Report No.:
EM201300418-1
Application No.:
ZJ00031163
Page 19 of 58
GFSK:
Report No.:
EM201300418-1
Application No.:
ZJ00031163
Page 20 of 58
8DPSK:
Click on the first or last page to see other ESQUIRE (serv.man3) service manuals if exist.