DOWNLOAD Harman Kardon ESQUIRE (serv.man3) Service Manual ↓ Size: 1.67 MB | Pages: 58 in PDF or view online for FREE

Model
ESQUIRE (serv.man3)
Pages
58
Size
1.67 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
esquire-sm3.pdf
Date

Harman Kardon ESQUIRE (serv.man3) EMC - CB Certificate ▷ View online

Report No.:
 
EM201300418-1 
                       
Application No.:
 
ZJ00031163  
                  
Page 17 of 58
 
 
4.2 FREQUENCY RANGE 
4.2.1 LIMITS 
EN300 328 clause 4.3.3 
fL > 2,4 GHz and fH < 2,4835 GHz 
4.2.2 TEST PROCEDURE 
Test EUT in normal conditions, and then repeat in extreme conditions. 
Measurement RBW = 100 kHz, VBW ≥ 100 kHz, average mode with 60 second sweeps selected. 
Pre-test the 3 modulation to find GFSK and 8DPSK is worse case, so only record GFSK and 
8DPSK test data. 
 
4.2.3 TEST SETUP 
 
 
 
 
 
 
 
4.2.4 TEST RESULTS 
Measurement Conditions 
Frequency spot with 
level ≤ -30dBm/100KHz
Limit (MHz) 
Temperature(°C) Voltage 
 
FL 
FH 
Lower 
Higher 
For GFSK 
AC Power 
25 ACnom 
2400.93 
2481.02 
FL>2400.0   FH< 2483.5 
-20 
ACmin 2400.96 
2481.01 
ACmax 2401.01 2480.99 
+55 
ACmin 2400.95 
2481.04 
ACmax 2400.99 2480.98 
For 8DPSK 
AC Power 
25 ACnom 
2400.41 
2480.79 
FL>2400.0   FH< 2483.5 
-20 
ACmin 2400.41 
2480.80 
ACmax 2400.37 2480.73 
+55 
ACmin 2400.36 
2480.78 
ACmax 2400.40 2480.76 
        
Antenna  
 
EUT
  
  
Receiver 
Report No.:
 
EM201300418-1 
                       
Application No.:
 
ZJ00031163  
                  
Page 18 of 58
 
FL: Lowest frequency of the power envelope, it is the frequency furthest below the frequency 
of maximum power where the output power drops below the level of –80 dBm/Hz spectral 
power density (-30 dBm if measured in a 100 kHz bandwidth) eirp. 
FH: Highest frequency of the power envelope, it is the frequency furthest above the frequency 
of maximum power where the output power drops below the level of –80 dBm/Hz spectral 
power density (-30 dBm if measured in a 100 kHz bandwidth) eirp. 
NOTE: ACnom =AC230V/50Hz;ACmin = AC207V/50Hz; ACmax= AC253V/50Hz 
TEST RESULTS: The unit does meet the requirements. 
 
       The test slots as below 
Report No.:
 
EM201300418-1 
                       
Application No.:
 
ZJ00031163  
                  
Page 19 of 58
 
GFSK: 
 
 
              
 
Report No.:
 
EM201300418-1 
                       
Application No.:
 
ZJ00031163  
                  
Page 20 of 58
 
8DPSK: 
 
 
Page of 58